Influence of fibers on flexural behavior and ductility of concrete beams reinforced with GFRP rebars

Engineering Structures - Tập 33 Số 5 - Trang 1754-1763 - 2011
Mohamed S. Issa1, Ibrahim M. Metwally1, Sherif M. Elzeiny1
1Reinforced Concrete Institute, Housing and Building National Research Center, Giza, Egypt

Tóm tắt

Từ khóa


Tài liệu tham khảo

Kamal, 2006, Ductility of concrete beams reinforced with hybrid FRP rebars, HBRC J, Hous & Build Res Cent, 2, 1

Ashour, 2006, Flexural and shear capacities of concrete beams reinforced with GFRP bars, Constr Build Mater, 20, 1005, 10.1016/j.conbuildmat.2005.06.023

Naaman AE, Jeong SM. Structural ductility of concrete beams prestressed with FRP tendons. In: Proceedings, 2nd int. RILEM symp. FRPRXS-2. Non-metric (FRP) Rienforcement for concrete structures. RILEM. 1995. p. 379–86.

Jaeger GL, Tadros G, Mufti AA. Balanced section, ductility, and deformability in concrete with FRP reinforcement. Research report no. 2-1995. Halifax (NS, Canada): Industry Center for Computer-Aided Engineering, Technical University of Nova Scotia; 1995. 29 pp.

ACI Committee 440.1R-06, 2006

Taniguchi, 1993, Ductile behavior of beams using FRP as tendons and transverse reinforcement, 651

Swamy, 1975, Flexural behavior of fiber concrete with conventional steel reinforcement, 187

Swamy, 1981, Deformation and ultimate strength in flexure of reinforced concrete beams made with steel fiber concrete, ACI J, 78, 395

Schupack, 1986, Durability of SFRC exposed to severe environments, 479

Alsayed, 1999, Ductility of concrete beams reinforced with FRP bars and steel fibers, J Compos Mater, 33, 1792, 10.1177/002199839903301902

Wang, 2005

Vijay, 2001, Bending behavior and deformability of glass fiber-reinforced polymer reinforced concrete members, ACI Struct J, 98, 834

Metwally, 2009, Evaluation of existing model for predicting of flexural behavior of GFRP-reinforced concrete members, HBRC J, Hous Build Res Cent, 5, 46

CSA-S6-00, 2000

Egyptian code for design and construction of concrete structures. ECP 203-2006.

Egyptian code for design and construction of FRP reinfiorced concrete structures. ECP 208-2005.

ACI Committee 318. Building code requirements for reinforced concrete. ACI 318-08. American Concrete Institute.

Sakai, 1999, Bond splitting behavior of continuous fiber reinforced concrete members, 1131

Benmokrane, 1996, Flexural response of concrete beams reinforced with FRP reinforcing bars, ACI Struct J, 91, 46

Mota, 2006, Critical review of deflection formulas for FRP-RC members, J Compos Constr, ASCE, 10, 183, 10.1061/(ASCE)1090-0268(2006)10:3(183)

Toutanji, 2000, Flexural behavior of concrete beams reinforced with glass fiber-reinforced polymer (GFRP) bars, ACI Struct J, 97, 712

Alsayed, 2000, Performance of glass fiber reinforced plastic bars as a reinforcing material for concrete structures, Composites B, 31, 555, 10.1016/S1359-8368(99)00049-9

Alsayed SH, Almusallam TH, Al-Salloum YA, Amjad MA. Glass fiber reinforced plastic rebars: properties and applications for concrete structures. Final report. Research project AR-14-35. Riyadh (Saudi Arabia): King Abdulaziz City for Science and Technology, KACST; 1997. 327 pp.