Influence of different flask systems on tooth displacement and framework misfit in mandibular fixed implant-supported complete dentures
Tài liệu tham khảo
Douglass, 2002, Will there be a need for complete dentures in the United States in 2020?, J Prosthet Dent, 87, 5, 10.1067/mpr.2002.121203
Bellini, 2009, Patients’ expectations and satisfaction of complete denture therapy and correlation with locus of control, J Oral Rehabil, 36, 682, 10.1111/j.1365-2842.2009.01967.x
Zarb, 2006
Baracat, 2011, Patients’ expectations before and evaluation after dental implant therapy, Clin Implant Dent Relat Res, 13, 141, 10.1111/j.1708-8208.2009.00191.x
Farina, 2012, An in vitro comparison of joint stability of implant-supported fixed prosthetic suprastructures retained with different prosthetic screws and levels of fit under masticatory simulation conditions, Int J Oral Maxillofac Implants, 27, 833
Romero, 2000, Accuracy of three corrective techniques for implant bar fabrication, J Prosthet Dent, 84, 602, 10.1067/mpr.2000.111494
Consani, 2006, Dimensional stability of distances between posterior teeth in maxillary complete dentures, Braz Oral Res, 20, 241, 10.1590/S1806-83242006000300011
Skinner, 1943, Physical properties of denture resins: Part I. Curing shrinkage and water sorption, J Am Dent Assoc, 30, 1845, 10.14219/jada.archive.1943.0394
Consani, 2006, Effect of water storage on tooth displacement in maxillary complete dentures, Braz Dent J, 17, 53, 10.1590/S0103-64402006000100012
Dos Santos, 2012, Influence of different metal flask systems on tooth displacement in complete upper dentures, Gerodontology, 29, 30, 10.1111/j.1741-2358.2010.00392.x
Consani, 2006, Influence of flask closure and flask cooling methods on tooth movement in maxillary dentures, J Prosthodont, 15, 229, 10.1111/j.1532-849X.2006.00111.x
Chen, 1988, Effect of denture thickness and curing cycle on the dimensional stability of acrylic resin denture bases, Dent Mater, 4, 20, 10.1016/S0109-5641(88)80083-6
Negreiros, 2009, Effect of flask closure method and post-pressing time on the displacement of maxillary denture teeth, Open Dent J, 3, 21, 10.2174/1874210600903010021
Jamani, 1998, Effect of denture thickness on tooth movement during processing of complete dentures, J Oral Rehabil, 25, 725, 10.1046/j.1365-2842.1998.00300.x
Shibayama, 2009, Effect of flasking and polymerization techniques on tooth movement in complete denture processing, J Prosthodont, 18, 259, 10.1111/j.1532-849X.2008.00421.x
Consani, 2002, Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases, J Prosthet Dent, 88, 285, 10.1067/mpr.2002.128447
Parker, 1974, Effective management of laboratory procedures and use of split-cast technique, J Prosthet Dent, 31, 325, 10.1016/0022-3913(74)90205-4
Boscato, 2005, Effect of investment material and water immersion time on tooth movement in complete denture, Eur J Prosthodont Restor Dent, 13, 164
Marchini, 2004, vol. 27, 213
Cardash, 1990, Effect of retention grooves on tooth-denture base bond, J Prosthet Dent, 64, 492, 10.1016/0022-3913(90)90051-D
Atkinson, 1962, An investigation into tooth movement during the packing and polymerizing of acrylic resin denture base materials, Aust Dent J, 7, 101, 10.1111/j.1834-7819.1962.tb01472.x
Consani, 2002, Effect of commercial acrylic resins on dimensional accuracy of the maxillary denture base, Braz Dent J, 13, 57
de Negreiros, 2009, The role of polymerization cycle and post-pressing time on tooth movement in complete dentures, Braz Oral Res, 23, 467, 10.1590/S1806-83242009000400018
Shigli, 2008, The effect of remount procedures on patient comfort for complete denture treatment, J Prosthet Dent, 99, 66, 10.1016/S0022-3913(08)60011-6