Influence of centrifugation conditions on the results of 77 routine clinical chemistry analytes using standard vacuum blood collection tubes and the new BD-Barricor tubes

Biochemia Medica - Tập 28 Số 1 - 2018
Janne Cadamuro1, Cornelia Mrazek2, Alexander Leichtle3, Ulrike Kipman4, Thomas K. Felder2, Helmut Wiedemann2, Hannes Oberkofler2, Martin Fiedler3, Elisabeth Haschke‐Becher2
1Department of Laboratory Medicine, Paracelsus Medical University, Salzburg, Austria
2Department of Laboratory Medicine, Paracelsus Medical University
3University Institute of Clinical Chemistry, Inselspital, Bern University Hospital, University of Bern
4UT SPSS Statistics, Hallein

Tóm tắt

Từ khóa


Tài liệu tham khảo

Lippi, 2008, Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories., Clin Chem Lab Med, 46, 764, 10.1515/CCLM.2008.170

Lippi, 2007, Influence of the centrifuge time of primary plasma tubes on routine coagulation testing., Blood Coagul Fibrinolysis, 18, 525, 10.1097/MBC.0b013e3281eec945

Lippi, 2006, Influence of centrifuge temperature on routine coagulation testing., Clin Chem, 52, 537, 10.1373/clinchem.2005.063149

Lesche, 2016, Does centrifugation matter? Centrifugal force and spinning time alter the plasma metabolome., Metabolomics, 12, 159, 10.1007/s11306-016-1109-3

Venous blood collection - FAQ. Becton Dickinson. Available at: http://www.bd.com/vacutainer/faqs/#venous_faq. Accessed April 19th 2017.

Vacuette Preanalytics Manual. Greiner BioOne. [Electronic version] Available at: https://www.gbo.com/fileadmin/user_upload/Downloads/Brochures/Brochures_Preanalytics/English/980183_Preanalytics_Manual_e_rev05_0216_lowres.pdf. Accessed April 25th 2017.

Centrifugation recommendations for S-monovette®. Sarstedt. [Electronic version] Available at: https://www.sarstedt.com/fileadmin/user_upload/99_Gebrauchsanweisungen/US/427_a_s_monovette_empf_zentri_USA_0610.pdf. Accessed April 25th 2017.

Roberts, 1999, Observations on centrifugation: Application to centrifuge development., Clin Chem, 45, 1889, 10.1093/clinchem/45.11.1889

Sédille-Mostafaie, 2013, Advancing haemostasis automation--successful implementation of robotic centrifugation and sample processing in a tertiary service hospital., Clin Chem Lab Med, 51, 1273, 10.1515/cclm-2012-0625

Boissier, 2017, A 2-min at 4500 g rather than a 15-min at 2200 g centrifugation does not impact the reliability of 10 critical coagulation assays., Clin Chem Lab Med, 55, e118, 10.1515/cclm-2016-0670

Suchsland, 2014, Optimizing centrifugation of coagulation samples in laboratory automation., Clin Chem Lab Med, 52, 1187, 10.1515/cclm-2014-0038

Møller, 2017, Evaluation of reduced centrifugation time and higher centrifugal force on chemistry and immunochemistry analytes in plasma and serum., Ann Clin Biochem, 54, 593, 10.1177/0004563216674030

Petrova, 2013, Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays., Clin Biochem, 46, 1298, 10.1016/j.clinbiochem.2013.06.018

Unger, 2007, Measurements of free hemoglobin and hemolysis index: Edta- or lithium-heparinate plasma?, Clin Chem, 53, 1717, 10.1373/clinchem.2007.091421

Ricós, 1999, Current databases on biological variation: Pros, cons and progress., Scand J Clin Lab Invest, 59, 491, 10.1080/00365519950185229

Barnhart, 2016, Choice of agreement indices for assessing and improving measurement reproducibility in a core laboratory setting., Stat Methods Med Res, 25, 2939, 10.1177/0962280214534651

Faul, 2007, A flexible statistical power analysis program for the social, behavioral, and biomedical sciences., Behav Res Methods, 39, 175, 10.3758/BF03193146

Chandler, 2010, Development of a rapid emergency hemorrhage panel., Transfusion, 50, 2547, 10.1111/j.1537-2995.2010.02753.x

Kao, 2010, Evaluation of a high-speed centrifuge with rapid preparation of plasma for coagulation testing to improve turnaround time., J Biomed Lab Sci, 22, 23

Dolci, 2014, Harmonization of automated hemolysis index assessment and use: Is it possible?, Clin Chim Acta, 432, 38, 10.1016/j.cca.2013.10.012