Indoor hospital air and the impact of ventilation on bioaerosols: a systematic review

Journal of Hospital Infection - Tập 103 Số 2 - Trang 175-184 - 2019
Rebecca E. Stockwell1,2, E Ballard3, Peter O’Rourke3, Luke D. Knibbs4, Lidia Morawska5, Scott C. Bell6,1,2
1Faculty of Medicine, The University of Queensland, Herston, Queensland, Australia
2Lung Bacteria Group, QIMR Berghofer Medical Research Institute, Herston, Queensland, Australia
3Statistical Support Group, QIMR Berghofer Medical Research Institute, Herston, Queensland, Australia
4School of Public Health, The University of Queensland, Herston, Queensland, Australia
5International Laboratory for Air Quality and Health, Queensland University of Technology, Brisbane, Queensland, Australia
6Adult Cystic Fibrosis Centre, The Prince Charles Hospital, Chermside, Queensland, Australia

Tóm tắt

Từ khóa


Tài liệu tham khảo

2010

Siegel, 2007, 2007 guideline for isolation precautions: Preventing transmission of infectious agents in health care settings, Am J Infect Control, 35, S65, 10.1016/j.ajic.2007.10.007

Boyce, 2002, Understanding and controlling methicillin-resistant Staphylococcus aureus infections, Infect Control Hosp Epidemiol, 23, 485, 10.1086/502092

Gralton, 2011, The role of particle size in aerosolised pathogen transmission: A review, J Infect, 62, 1

Morawska, 2006, Droplet fate in indoor environments, or can we prevent the spread of infection?, Indoor Air, 16, 335, 10.1111/j.1600-0668.2006.00432.x

Prussin, 2015, Sources of airborne microorganisms in the built environment, Microbiome, 3, 78, 10.1186/s40168-015-0144-z

Li, 2007, Role of ventilation in airborne transmission of infectious agents in the built environment – a multidisciplinary systematic review, Indoor Air, 17, 2, 10.1111/j.1600-0668.2006.00445.x

Tang, 2006, Factors involved in the aerosol transmission of infection and control of ventilation in healthcare premises, J Hosp Infect, 64, 100, 10.1016/j.jhin.2006.05.022

Mouchtouri, 2015, Legionnaires' Disease in hotels and passenger ships: A systematic review of evidence, sources, and contributing factors, J Travel Med, 22, 325, 10.1111/jtm.12225

Tomlinson, 2003, SARS: Experience at Prince of Wales Hospital, Hong Kong, Lancet, 361, 1486, 10.1016/S0140-6736(03)13218-7

Hoge, 1994, An epidemic of pneumococcal disease in an overcrowded, inadequately ventilated jail, N Engl J Med, 331, 643, 10.1056/NEJM199409083311004

Gao, 2016, Building ventilation as an effective disease intervention strategy in a dense indoor contact network in an ideal city, PLoS One, 11, e0162481, 10.1371/journal.pone.0162481

Li, 2005, Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong, Indoor Air, 15, 83, 10.1111/j.1600-0668.2004.00317.x

AHRAE. 7.1 Air Conditioning in Disease Prevention and Treatment, 2007

Dharmadhikari, 2012, Surgical face masks worn by patients with multidrug-resistant tuberculosis: impact on infectivity of air on a hospital ward, Am J Respir Crit Care Med, 185, 1104, 10.1164/rccm.201107-1190OC

Bloch, 1985, Measles outbreak in a pediatric practice: airborne transmission in an office setting, Pediatrics, 75, 676, 10.1542/peds.75.4.676

Leclair, 1980, Airborne transmission of chickenpox in a hospital, N Engl J Med, 302, 450, 10.1056/NEJM198002213020807

Killingley, 2013, Routes of influenza transmission, Influenza Other Respir Viruses, 7, 42, 10.1111/irv.12080

Kulkarni, 2016, Evidence of respiratory syncytial virus spread by aerosol. Time to revisit infection control strategies?, Am J Respir Crit Care Med, 194, 308, 10.1164/rccm.201509-1833OC

Warfel, 2012, Airborne transmission of Bordetella pertussis, J Infect Dis, 206, 902, 10.1093/infdis/jis443

Bonifait, 2015, Detection and quantification of airborne norovirus during outbreaks in healthcare facilities, Clin Infect Dis, 61, 299, 10.1093/cid/civ321

Hara, 2016, Airborne transmission from a neonate with Netherton syndrome during an outbreak of MRSA, Pediatr Int, 58, 518, 10.1111/ped.12841

Best, 2010, The potential for airborne dispersal of Clostridium difficile from symptomatic patients, Clin Infect Dis, 50, 1450, 10.1086/652648

Roberts, 2008, Aerial dissemination of Clostridium difficile spores, BMC Infect Dis, 8, 7, 10.1186/1471-2334-8-7

Bernstein, 1983, Exposures to respirable, airborne Penicillium from a contaminated ventilation system: Clinical, environmental and epidemiological aspects, Am Ind Hyg Assoc J, 44, 161, 10.1080/15298668391404581

Zemouri, 2017, A scoping review on bio-aerosols in healthcare and the dental environment, PLoS One, 12, e0178007, 10.1371/journal.pone.0178007

Sehulster, 2004

Kärki, 2019, Burden of healthcare-associated infections in European acute care hospitals, Wiener Medizinische Wochenschrift, 169, 3, 10.1007/s10354-018-0679-2

Mitchell, 2017, The burden of healthcare-associated infection in Australian hospitals: A systematic review of the literature, Infect Dis Health, 22, 117, 10.1016/j.idh.2017.07.001

Arefian, 2016, Extra length of stay and costs because of health care-associated infections at a German university hospital, Am J Infect Control, 44, 160, 10.1016/j.ajic.2015.09.005

Tellier, 2019, Recognition of aerosol transmission of infectious agents: A commentary, BMC Infect Dis, 19, 101, 10.1186/s12879-019-3707-y

Roy, 2004, Airborne transmission of communicable infection – the elusive pathway, N Engl J Med, 350, 1710, 10.1056/NEJMp048051

Beggs, 2008, The ventilation of multiple-bed hospital wards: Review and analysis, Am J Infect Control, 36, 250, 10.1016/j.ajic.2007.07.012

Centers for Disease Control and Prevention Diseases and organisms in the healthcare setting

Friedrich, 2019, Control of hospital acquired infections and antimicrobial resistance in Europe: The way to go, Wiener Medizinische Wochenschrift, 169, 25, 10.1007/s10354-018-0676-5

Davis, 1996, Chapter 6: Normal flora

Clark, 2009, Some aspects of the airborne transmission of infection, J R Soc Interface, 6, S767

Findley, 2013, Topographic diversity of fungal and bacterial communities in human skin, Nature, 498, 367, 10.1038/nature12171

Babady, 2016, Hospital-associated infections, Microbiol Spectr, 4, 10.1128/microbiolspec.DMIH2-0003-2015

Bolookat, 2018, Assessment of bioaerosol particle characteristics at different hospital wards and operating theaters: A case study in Tehran, Methods, 5, 1588

Hospodsky, 2012, Human occupancy as a source of indoor airborne bacteria, PLoS One, 7, e34867, 10.1371/journal.pone.0034867

Meadow, 2014, Indoor airborne bacterial communities are influenced by ventilation, occupancy, and outdoor air source, Indoor Air, 24, 41, 10.1111/ina.12047

Al-Shahwani, 2005, Bacterial distribution analysis of the atmosphere of two hospitals in Ibb, Yemen, East Mediterr Health J, 11, 1115

Andersson, 2012, Traffic flow in the operating room: An explorative and descriptive study on air quality during orthopedic trauma implant surgery, Am J Infect Control, 40, 750, 10.1016/j.ajic.2011.09.015

Apisarnthanarak, 2012, Air quality of a hospital after closure for black-water flood: An occupational-health concern?, Infect Control Hosp Epidemiol, 33, 1285, 10.1086/668445

Augustowska, 2006, Variability of airborne microflora in a hospital ward within a period of one year, Ann Agric Environ Med, 13, 99

Aydin Cakir, 2013, Determination and comparison of microbial loads in atmospheres of two hospitals in Izmir, Turkey, Ann Agric Environ Med, 20, 106

Azimi, 2013, Fungal air quality in hospital rooms: A case study in Tehran, Iran, J Environ Health Sci Eng, 11, 30, 10.1186/2052-336X-11-30

Brun, 2013, Fungal spore concentrations in two haematopoietic stem cell transplantation (HSCT) units containing distinct air control systems, Epidemiol Infect, 141, 875, 10.1017/S0950268812001124

Cristina, 2012, Can particulate air sampling predict microbial load in operating theatres for arthroplasty?, PLoS One, 7, e52809, 10.1371/journal.pone.0052809

Gniadek, 2007, Intensive care unit environment contamination with fungi, Adv Med Sci, 52, 283

Gniadek, 2011, Cytotoxicity of Aspergillus fungi isolated from hospital environment, Pol J Microbiol, 60, 59, 10.33073/pjm-2011-008

Hoseinzadeh, 2013, Evaluation of bioaerosols in five educational hospitals wards air in Hamedan, during 2011–2012, Jundishapur J Microbiol, 6, e10704, 10.5812/jjm.10704

Jung, 2015, Indoor air quality varies with ventilation types and working areas in hospitals, Build Environ, 85, 190, 10.1016/j.buildenv.2014.11.026

Kim, 2010, Distribution characteristics of airborne bacteria and fungi in the general hospitals of Korea, Ind Health, 48, 236, 10.2486/indhealth.48.236

Krajewska-Kulak, 2007, Indoor air studies of fungi contamination at the Neonatal Department and Intensive Care Unit an Palliative Care in Kavala Hospital in Greece, Adv Med Sci, 52, 11

Krajewska-Kulak, 2009, Indoor air studies of fungi contamination at the Department of Pulmonology and Internal Medicine in Kavala Hospital in Greece, Adv Med Sci, 54, 264, 10.2478/v10039-009-0048-x

Landrin, 2005, Monitoring air sampling in operating theatres: can particle counting replace microbiological sampling?, J Hosp Infect, 61, 27, 10.1016/j.jhin.2005.03.002

Mirhoseini, 2015, Monitoring of airborne bacteria and aerosols in different wards of hospitals – Particle counting usefulness in investigation of airborne bacteria, Ann Agric Environ Med, 22, 670, 10.5604/12321966.1185772

Mirzaei, 2014, Quantitative and qualitative evaluation of bio-aerosols in surgery rooms and emergency department of an educational hospital, Jundishapur J Microbiol, 7, e11688, 10.5812/jjm.11688

Napoli, 2012, Air sampling methods to evaluate microbial contamination in operating theatres: Results of a comparative study in an orthopaedics department, J Hosp Infect, 80, 128, 10.1016/j.jhin.2011.10.011

Napoli, 2012, Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres, BMC Public Health, 12, 594, 10.1186/1471-2458-12-594

Nasir, 2013, Evaluation of total concentration and size distribution of bacterial and fungal aerosol in healthcare built environments, Indoor Built Environ, 24, 269, 10.1177/1420326X13510925

Ökten, 2015, Airborne microfungi in oncology service of medical school hospital of Trakya University, Indoor Built Environ, 24, 771, 10.1177/1420326X14533712

Ortiz, 2009, A study of air microbe levels in different areas of a hospital, Curr Microbiol, 59, 53, 10.1007/s00284-009-9398-7

Panagopoulou, 2002, Environmental surveillance of filamentous fungi in three tertiary care hospitals in Greece, J Hosp Infect, 52, 185, 10.1053/jhin.2002.1298

Pasquarella, 2012, Microbial air monitoring in operating theatres: Experience at the University Hospital of Parma, J Hosp Infect, 81, 50, 10.1016/j.jhin.2012.01.007

Perdelli, 2006, A problem of hospital hygiene: the presence of aspergilli in hospital wards with different air-conditioning features, Am J Infect Control, 34, 264, 10.1016/j.ajic.2005.12.004

Pini, 2004, Two years of a fungal aerobiocontamination survey in a Florentine haematology ward, Eur J Epidemiol, 19, 693, 10.1023/B:EJEP.0000036778.13006.16

Qi, 2012, Detection and analysis of airborne aerobes and Gram-negative bacteria and spread identification of airborne Escherichia coli using ERIC-PCR in hospital environment, Afr J Microbiol Res, 6, 58

Reboux, 2014, A 10-year survey of fungal aerocontamination in hospital corridors: a reliable sentinel to predict fungal exposure risk?, J Hosp Infect, 87, 34, 10.1016/j.jhin.2014.02.008

Rios-Yuil, 2012, Aeromycological study at the intensive care unit of the "Dr. Manuel Gea Gonzalez" General Hospital, Braz J Infect Dis, 16, 432, 10.1016/j.bjid.2012.08.012

Sautour, 2007, Prospective survey of indoor fungal contamination in hospital during a period of building construction, J Hosp Infect, 67, 367, 10.1016/j.jhin.2007.09.013

Sautour, 2009, Profiles and seasonal distribution of airborne fungi in indoor and outdoor environments at a French hospital, Sci Total Environ, 407, 3766, 10.1016/j.scitotenv.2009.02.024

Stocks, 2010, Predicting bacterial populations based on airborne particulates: a study performed in nonlaminar flow operating rooms during joint arthroplasty surgery, Am J Infect Control, 38, 199, 10.1016/j.ajic.2009.07.006

Tormo-Molina, 2012, Monitoring the occurrence of indoor fungi in a hospital, Rev Iberoam Micol, 29, 227, 10.1016/j.riam.2012.04.002

Wan, 2011, Long-term surveillance of air quality in medical center operating rooms, Am J Infect Control, 39, 302, 10.1016/j.ajic.2010.07.006

Yu, 2015, Characteristics of airborne micro-organisms in a neurological intensive care unit: Results from China, J Int Med Res, 43, 332