Increasing Lesion Dimensions of Bipolar Ablation by Modulating the Surface Area of the Return Electrode
Tài liệu tham khảo
Nakagawa, 1995, Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation, Circulation, 91, 2264, 10.1161/01.CIR.91.8.2264
Winterfield, 2016, Lesion size and safety comparison between the novel flex tip on the FlexAbility ablation catheter and the solid tips on the ThermoCool and ThermoCool SF ablation catheters, J Cardiovasc Electrophysiol, 27, 102, 10.1111/jce.12835
Leshem, 2020, Temperature-controlled radiofrequency ablation using irrigated catheters: maximizing ventricular lesion dimensions while reducing steam-pop formation, J Am Coll Cardiol EP, 6, 83
Koruth, 2012, Bipolar irrigated radiofrequency ablation: a therapeutic option for refractory intramural atrial and ventricular tachycardia circuits, Heart Rhythm, 9, 1932, 10.1016/j.hrthm.2012.08.001
Nguyen, 2016, Clinical and biophysical evaluation of variable bipolar configurations during radiofrequency ablation for treatment of ventricular arrhythmias, Heart Rhythm, 13, 2161, 10.1016/j.hrthm.2016.07.011
Gizurarson, 2014, Bipolar ablation for deep intra-myocardial circuits: human ex vivo development and in vivo experience, EP Europace Cardiology, 16, 1684, 10.1093/europace/euu001
Cronin, 2020, 2019 HRS/EHRA/APHRS/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias: executive summary, Heart Rhythm, 17, e155, 10.1016/j.hrthm.2019.03.014
Teh, 2014, Bipolar radiofrequency catheter ablation for refractory ventricular outflow tract arrhythmias, J Cardiovasc Electrophysiol, 25, 1093, 10.1111/jce.12460
Shapira-Daniels, 2019, Modulating the baseline impedance: an adjunctive technique for maximizing radiofrequency lesion dimensions in deep and intramural ventricular substrate, Circ Arrhythm Electrophysiol, 12, 10.1161/CIRCEP.119.007336
Barkagan, 2018, Effect of baseline impedance on ablation lesion dimensions, Circ Arrhythm Electrophysiol, 11, 10.1161/CIRCEP.118.006690
Tschabrunn, 2016, A swine model of infarct-related reentrant ventricular tachycardia: electroanatomic, magnetic resonance, and histopathological characterization, Heart Rhythm, 13, 262, 10.1016/j.hrthm.2015.07.030
Leshem, 2017, Evaluation of ablation catheter technology: comparison between thigh preparation model and an in vivo beating heart, Heart Rhythm, 14, 1234, 10.1016/j.hrthm.2017.04.035
Shapira-Daniels, 2019, Novel irrigated temperature-controlled lattice ablation catheter for ventricular ablation: a preclinical multimodality biophysical characterization, Circ Arrhythm Electrophysiol, 12, 10.1161/CIRCEP.119.007661