Inappropriate shocks in the subcutaneous ICD: Incidence, predictors and management

International Journal of Cardiology - Tập 195 - Trang 126-133 - 2015
Louise R.A. Olde Nordkamp1, Tom F. Brouwer1, Craig Barr2, Dominic Theuns3, Lucas V.A. Boersma4, Jørgen Johansen5, Petr Neužil6, Arthur A.M. Wilde1, Nathan Carter7, Michael Husby7, Pier D. Lambiase8, Reinoud E. Knops9
1Academic Medical Center, Amsterdam, Netherlands
2Russels Hall Hospital, Dudley, United Kingdom.
3Erasmus Medical Centre, Rotterdam, Netherlands
4Sint Antonius Hospital, Nieuwegein, Netherlands
5Odense University Hospital, Odense, Denmark
6Na Homolce Hospital, Prague, Czech Republic
7Boston Scientific, St. Paul, MN, USA
8The Heart Hospital, London, United Kingdom
9Academic Medical Center, Amsterdam, Netherlands. Electronic address: [email protected].

Tóm tắt

Từ khóa


Tài liệu tham khảo

1997, A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators, N. Engl. J. Med., 33, 1576

Moss, 2002, Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction, N. Engl. J. Med., 346, 877, 10.1056/NEJMoa013474

Lee, 2009, ICD lead proarrhythmia cured by lead extraction, Heart Rhythm., 6, 613, 10.1016/j.hrthm.2009.01.039

Kleemann, 2007, Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10years, Circulation, 115, 2474, 10.1161/CIRCULATIONAHA.106.663807

Bardy, 2010, An entirely subcutaneous implantable cardioverter-defibrillator, N. Engl. J. Med., 363, 36, 10.1056/NEJMoa0909545

Gold, 2012, Head-to-head comparison of arrhythmia discrimination performance of subcutaneous and transvenous ICD arrhythmia detection algorithms: the START study, J. Cardiovasc. Electrophysiol., 23, 359, 10.1111/j.1540-8167.2011.02199.x

Olde Nordkamp, 2012, The entirely subcutaneous implantable cardioverter-defibrillator: initial clinical experience in a large Dutch cohort, J. Am. Coll. Cardiol., 60, 1933, 10.1016/j.jacc.2012.06.053

Burke, 2015, Safety and efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE Study and EFFORTLESS Registry, J. Am. Coll. Cardiol., 65, 1605, 10.1016/j.jacc.2015.02.047

Tu, 2014, Subcutaneous implantable-defibrillator is better to be a “collaborator” rather than a “replacement”, Int. J. Cardiol., 177, 51, 10.1016/j.ijcard.2014.09.072

Gold, 2014, Use of a discrimination algorithm to reduce inappropriate shocks with a subcutaneous implantable cardioverter-defibrillator, Heart Rhythm., 11, 1352, 10.1016/j.hrthm.2014.04.012

Lambiase, 2014, Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry, Eur. Heart J., 35, 1657, 10.1093/eurheartj/ehu112

Pedersen, 2012, Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD: design and rationale of the EFFORTLESS S-ICD Registry, Pacing Clin. Electrophysiol., 35, 574, 10.1111/j.1540-8159.2012.03337.x

van Rees, 2011, Inappropriate implantable cardioverter-defibrillator shocks incidence, predictors, and impact on mortality, J. Am. Coll. Cardiol., 57, 556, 10.1016/j.jacc.2010.06.059

Daubert, 2008, Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact, J. Am. Coll. Cardiol., 51, 1357, 10.1016/j.jacc.2007.09.073

Tan, 2014, Impact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis, Circ. Arrhythm. Electrophysiol., 7, 164, 10.1161/CIRCEP.113.001217

Moss, 2012, Reduction in inappropriate therapy and mortality through ICD programming, N. Engl. J. Med., 367, 2275, 10.1056/NEJMoa1211107

Gasparini, 2013, Effect of long-detection interval vs standard-detection interval for implantable cardioverter-defibrillators on antitachycardia pacing and shock delivery: the ADVANCE III randomized clinical trial, JAMA, 309, 1903, 10.1001/jama.2013.4598

Weiss, 2013, Safety and efficacy of a totally subcutaneous implantable-cardioverter defibrillator, Circulation, 128, 944, 10.1161/CIRCULATIONAHA.113.003042

Gold, 2014, Use of a discrimination algorithm to reduce inappropriate shocks with a subcutaneous implantable cardioverter-defibrillator, Heart Rhythm., 11, 1352, 10.1016/j.hrthm.2014.04.012

Olde Nordkamp, 2014, Which patients are not suitable for a subcutaneous ICD: incidence and predictors of failed QRS-T-wave morphology screening, J. Cardiovasc. Electrophysiol., 25, 494, 10.1111/jce.12343

Kooiman, 2014, Inappropriate subcutaneous implantable cardioverter-defibrillator shocks due to T-wave oversensing can be prevented: implications for management, Heart Rhythm., 11, 426, 10.1016/j.hrthm.2013.12.007

Brisben, 2015, A new algorithm to reduce inappropriate therapy in the S-ICD system, J. Cardiovasc. Electrophysiol., 26, 417, 10.1111/jce.12612