In vitro and in vivo evaluation of the bioactivity of hydroxyapatite-coated polyetheretherketone biocomposites created by cold spray technology

Acta Biomaterialia - Tập 9 Số 4 - Trang 6177-6187 - 2013
Jae Hyup Lee1,2, Hae Lin Jang3, Kyung Mee Lee1, Hae-Ri Baek1,2, Kyoungsuk Jin3, Kug Sun Hong3, Jun Hong Noh4, Hyun-Kyung Lee1,2
1Department of Orthopedic Surgery, College of Medicine, Seoul National University, SMG-SNU Boramae Medical Center, Seoul 156-707, Republic of Korea
2Institute of Medical and Biological Engineering, Seoul National University Medical Research Center, Seoul National University, Seoul 110-799, Republic of Korea
3Department of Materials Science and Engineering, College of Engineering, Seoul National University, Seoul 151-744, Republic of Korea
4KRICT-EPFL Global Research Laboratory, Advanced Materials Division, Korea Research Institute of Chemical Technology (KRICT), Daejeon 305-600, Republic of Korea

Tóm tắt

Từ khóa


Tài liệu tham khảo

Kurtz, 2007, PEEK biomaterials in trauma, orthopedic, and spinal implants, Biomaterials, 28, 4845, 10.1016/j.biomaterials.2007.07.013

Ponnappan, 2009, Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation, Spine J, 9, 263, 10.1016/j.spinee.2008.08.002

Nieminen, 2008, Amorphous and crystalline polyetheretherketone: mechanical properties and tissue reactions during a 3-year follow-up, J Biomed Mater Res A, 84A, 377, 10.1002/jbm.a.31310

Evans, 1998, Composite technology in load-bearing orthopaedic implants, Biomaterials, 19, 1329, 10.1016/S0142-9612(97)00217-2

Jones, 1985, Mechanical properties of poly(ether-ether-ketone) for engineering applications, Polymer, 26, 1385, 10.1016/0032-3861(85)90316-7

Kalika, 1993, Influence of crystallinity on the dielectric-relaxation behavior of poly(ether ether ketone), Macromolecules, 26, 4252, 10.1021/ma00068a028

Cutler, 2006, Comparison of polyetheretherketone cages with femoral cortical bone allograft as a single-piece interbody spacer in transforaminal lumbar interbody fusion, J Neurosurg-Spine, 5, 534, 10.3171/spi.2006.5.6.534

Song, 2010, Plate augmentation in anterior cervical discectomy and fusion with cage for degenerative cervical spinal disorders, Eur Spine J, 19, 1677, 10.1007/s00586-010-1283-3

Kulkarni, 2007, Solis cage (PEEK) for anterior cervical fusion: preliminary radiological results with emphasis on fusion and subsidence, Spine J, 7, 205, 10.1016/j.spinee.2006.03.002

Sethi, 2009, Transforaminal lumbar interbody fusion using unilateral pedicle screws and a translaminar screw, Eur Spine J, 18, 430, 10.1007/s00586-008-0825-4

Noiset, 1999, Fibronectin adsorption or and covalent grafting on chemically modified PEEK film surfaces, J Biomater Sci-Polym Ed, 10, 657, 10.1163/156856299X00865

Abu Bakar MS, Cheng MH, Tang SM, Yu SC, Liao K, Tan CT, et al. Tensile properties, tension–tension fatigue and biological response of polyetheretherketone–hydroxyapatite composites for load-bearing orthopedic implants. Biomaterials 2003;24:2245–50.

Tan, 2003, Scaffold development using selective laser sintering of polyetheretherketone–hydroxyapatite biocomposite blends, Biomaterials, 24, 3115, 10.1016/S0142-9612(03)00131-5

Wong, 2009, Mechanical properties and in vitro response of strontium-containing hydroxyapatite/polyetheretherketone composites, Biomaterials, 30, 3810, 10.1016/j.biomaterials.2009.04.016

Yu, 2005, In vitro apatite formation and its growth kinetics on hydroxyapatite/polyetheretherketone biocomposites, Biomaterials, 26, 2343, 10.1016/j.biomaterials.2004.07.028

Converse, 2007, Processing and tensile properties of hydroxyapatite-whisker-reinforced polyetheretherketone, Biomaterials, 28, 927, 10.1016/j.biomaterials.2006.10.031

Han, 2010, The electron beam deposition of titanium on polyetheretherketone (PEEK) and the resulting enhanced biological properties, Biomaterials, 31, 3465, 10.1016/j.biomaterials.2009.12.030

Bureau, 2009

Wu, 2009, Investigation of hydroxyapatite-coated polyether ether ketone composites by gas plasma sprays, Surf Coat Technol, 203, 2755, 10.1016/j.surfcoat.2009.02.115

Comyn, 1996, Plasma-treatment of polyetheretherketone (PEEK) for adhesive bonding, Int J Adhes Adhes, 16, 97, 10.1016/0143-7496(96)89798-3

Tokarev, 1996, Structure of aluminum powder coatings prepared by cold gas dynamic spraying, Met Sci Heat Treat, 38, 136, 10.1007/BF01401446

Schmidt, 2006, Development of a generalized parameter window for cold spray deposition, Acta Mater, 54, 729, 10.1016/j.actamat.2005.10.005

Phani, 2007, Effect of heat treatment on properties of cold sprayed nanocrystalline copper alumina coatings, Acta Mater, 55, 4741, 10.1016/j.actamat.2007.04.044

Lima, 2002, Microstructural characteristics of cold-sprayed nanostructured WC-Co coatings, Thin Solid Films, 416, 129, 10.1016/S0040-6090(02)00631-4

Qiu D, Zhang M, Grøndahl L. A novel composite porous coating approach for bioactive titanium-based orthopedic implants. J Biomed Mater Res A 2012. Available from: http://onlinelibrary.wiley.com/doi/10.1002/jbm.a.34372/full.

Sanpo, 2009, Antibacterial property of cold-sprayed HA-Ag/PEEK coating, J Therm Spray Technol, 18, 10, 10.1007/s11666-008-9283-0

Kitsugi, 1995, Transmission electron microscopy observations at the interface of bone and four types of calcium phosphate ceramics with different calcium/phosphorus molar ratios, Biomaterials, 16, 1101, 10.1016/0142-9612(95)98907-V

Luo, 1996, Preparing hydroxyapatite powders with controlled morphology, Biomaterials, 17, 1959, 10.1016/0142-9612(96)00019-1

Lee, 2010, Quantitative comparison of novel CaO–SiO2–P2O5–B2O3 glass-ceramics (BGS-7) with hydroxyapatite as bone graft extender in rabbit ilium, Tissue Eng Regen Med, 7, 540

Lee, 2005, Biomechanical and histomorphometric study on the bone–screw interface of bioactive ceramic-coated titanium screws, Biomaterials, 26, 3249, 10.1016/j.biomaterials.2004.08.033

Lee, 2011, Bioactive ceramic coating of cancellous screws improves the osseointegration in the cancellous bone, J Orthop Sci, 16, 291, 10.1007/s00776-011-0047-1

Landor, 2007, Hydroxyapatite porous coating and the osteointegration of the total hip replacement, Arch Orthop Trauma Surg, 127, 81, 10.1007/s00402-006-0235-1

Merolli, 2003, Histomorphological study of bone response to hydroxyapatite coating on stainless steel, J Mater Sci-Mater Med, 14, 327, 10.1023/A:1022979831639

Moroni, 1996, Improvement of the bone–pin interface with hydroxyapatite coating: an in vivo long-term experimental study, J Orthop Trauma, 10, 236, 10.1097/00005131-199605000-00003

Noiset, 1999, Fibronectin adsorption or/and covalent grafting on chemically modified PEEK film surfaces, J Biomater Sci, Polym Ed, 10, 657, 10.1163/156856299X00865

Bodhak, 2009, Role of surface charge and wettability on early stage mineralization and bone cell–materials interactions of polarized hydroxyapatite, Acta Biomater, 5, 2178, 10.1016/j.actbio.2009.02.023

Lopes, 1999, Hydrophobicity, surface tension, and zeta potential measurements of glass-reinforced hydroxyapatite composites, J Biomed Mater Res, 45, 370, 10.1002/(SICI)1097-4636(19990615)45:4<370::AID-JBM12>3.0.CO;2-0

Yang, 2008, Biomimetic calcium phosphate coating on electrospun poly(ɛ-caprolactone) scaffolds for bone tissue engineering, Chem Eng J, 137, 154, 10.1016/j.cej.2007.07.076

Thian, 2011, Surface modification of magnetron-sputtered hydroxyapatite thin films via silicon substitution for orthopaedic and dental applications, Surf Coat Technol, 205, 3472, 10.1016/j.surfcoat.2010.12.012

Ito, 2005, A composite of hydroxyapatite with electrospun biodegradable nanofibers as a tissue engineering material, J Biosci Bioeng, 100, 43, 10.1263/jbb.100.43

Lee, 2011, Combined effects of porous hydroxyapatite and demineralized bone matrix on bone induction: in vitro and in vivo study using a nude rat model, Biomed Mater, 6, 015008, 10.1088/1748-6041/6/1/015008