In Situ Experiments with X ray Tomography: an Attractive Tool for Experimental Mechanics

Jean‐Yves Buffière1, Éric Maire1, Jérôme Adrien1, J.P. Masse2, Élodie Boller3
1INSA-Lyon MATEIS CNRS UMR 5510, LyonTech Campus Bat Saint Exupery 25 Av. Jean Capelle, 69621, Villeurbanne Cedex, France
2SIMaP, Saint Martin d’Heres Cedex, France
3ESRF, Grenoble Cedex 9, France

Tóm tắt

Từ khóa


Tài liệu tham khảo

Dalmaz A, Ducret D, El Guerjouma R, Reynaud P, Franciosi P, Rouby D, Fantozzi G, Baboux JC (2000) Elastic moduli of a 2.5D C-f/SiC composite: experimental and theoretical estimates. Compos Sci Technol 60(6):913–925

Baste S, Elguerjouma R, Audoin B (1992) Effect of microcracking on the macroscopic behavior of ceramic matrix composites—ultrasonic evaluation of anisotropic damage. Mech Mater 14(1):15–31

Martin CF, Josserond C, Salvo L, Blandin J-J, Cloetens P, Boller E (2000) Characterisation by X-ray micro-tomography of cavity coalescence during superplastic deformation. Scr Mater 42:375–381

Buffiere JY, Maire E, Cloetens P, Lormand G, Fougeres R (1999) Characterization of internal damage in a MMCp using X-ray synchrotron phase contrast microtomography. Acta Mater 47(5):1613–1625

Babout L, Maire E, Buffiere JY, Fougeres R (2001) Characterization by X-ray computed tomography of decohesion, porosity growth and coalescence in model metal matrix composites. Acta Mater 49(11):2055–2063

Liu XC, Bathias C (1993) Defects in squeeze-cast AL2O3/AL alloy composites and their effects on mechanical-properties. Compos Sci Technol 6(3):245–252

Kinney JH, Breunig TM, Starr TL, Haupt D, Nichols MC, Stock SR, Butts MD, Saroyan RA (1993) X-ray tomographic study of chemical vapor infiltration processing of ceramic composites. Science 260(5109):789–792

Baaklini GY, Bhatt RT, Eckel AJ, Engler P, Casstelli MG, Rauser RW (1995) X-ray microtomography of ceramic and metal-matrix composites. Mater Eval 53(9):1040–1044

London B, Yancey RN, Smith JA (1990) High-resolution X-ray computed-tomography of composite-materials. Mater Eval 48(5):604–608

Hirano T, Usami K, Tanaka Y, Masuda C (1995) In situ X-ray ct under tensile loading using synchrotron-radiation. J Mater Res 10(2):381–386

Stock SR (2008) Recent advances in X-ray microtomography applied to materials. Int Mater Rev 53(3):129–181

Stock SR (1999) X-ray microtomography of materials. Int Mater Rev 44(4):141–164

Guvenilir A, Breunig TM, Kinney JH, Stock SR (1997) Direct observation of crack opening as a function of applied load in the interior of a notched tensile sample of Al-Li 2090. Acta Mater 45(5):1977–1987

Beckmann F, Grupp R, Haibel A, Huppmann M, Nothe M, Pyzalla A, Reimers W, Schreyer A, Zettler R (2007) In situ syncrotron X-ray microtomography studies of microstructure and damage evolution in engineering materials. Adv Eng Mater 9(11):939–950

http://rsbweb.nih.gov/ij/ —freeware. Accessed 24/09/09

www.vsg3d.com . Accessed 24/09/09

www.volumegraphics.com . Accessed 24/09/09

Youssef S, Maire E, Gartner R (2005) Finite element modelling of the actual structure of cellular materials determined by X ray tomography. Acta Mater 53:719–730

Caty O, Maire E, Youssef S, Bouchet R (2008) Modeling the properties of closed-cell cellular materials from tomography images using finite shell elements. Acta Mater 56:5524–5534

Madi K, Forest S, Boussuge M, Gailliegue S, Lataste E, Buffiere J-Y, Bernard D, Jeulin D (2007) Finite element simulations of the deformation of fused-cast refractories based on X-ray computed tomography. Comput Mater Sci 39(1):224–229

Buffiere JY, Cloetens P, Ludwig W, Maire E, Salvo L (2008) In situ X-ray tomography studies of microstructural evolution combined with 3D modeling. MRS Bull 33(6):611–619

Kak AC, Slaney M (1988) Principles of computerized tomographic imaging. IEEE, New York

Stock S (2008) MicroComputed tomography: methodology and applications. CRC

Banhart J (2008) Advanced tomographic methods in materials research and engineering. Oxford University Press

Mokso R, Cloetens P, Maire E, Ludwig W, Buffiere JY (2007) Nanoscale zoom tomography with hard X rays using Kirkpatrick–Baez optics. Appl Phys Lett 90(14):144104

Feldkamp LA, Davis LC, Kress JW (1984) Practical cone beam algorithm. J Opt Soc Am A1:612–619

Cloetens P, PateyronSalome M, Buffiere JY, Peix G, Baruchel J, Peyrin F, Schlenker M (1997) Observation of microstructure and damage in materials by phase sensitive radiography and tomography. J Appl Phys 81(9):5878–5886

Cloetens P, Ludwig W, Baruchel J, VanDyck D, Van Landuyt J, Guigay JP, Schlenker M (1999) Holotomography: quantitative phase tomography with micrometer resolution using hard synchrotron X rays. Appl Phys Lett 75:2912

Salvo L, Cloetens P, Maire E, Zabler S, Blandin JJ, Buffiere JY, Ludwig W, Boller E, Bellet D, Josserond C (2003) X-ray micro-tomography an attractive characterisation technique in materials science. Nucl Instrum Methods Phys Res, B 200:273–286

Borbely A, Csikor FF, Zabler S, Cloetens P, Biermann H (2004) Three-dimensional characterization of the microstructure of a metal matrix composite by holotomography. Mater Sci Eng, A 367:40–50

Toda H, Sinclair I, Buffiere JY, Maire E, Connolley T, Joyce M, Khor KH, Gregson P (2003) Assessment of the fatigue crack closure phenomenon in damage-tolerant aluminium alloy by in situ high-resolution synchrotron X-ray microtomography. Philos Mag 83(21):2429–2448

Engelhardt M, Baumann J, Schuster M, Kottler C, Pfeiffer F, Bunk O, David C (2007) High-resolution differential phase contrast imaging using a magnifying projection geometry with a microfocus X-ray source. Appl Phys Lett 90(22):224101

Davis GR, Elliott JC (2006) Artefacts in X-ray microtomography of materials. Mater Sci Technol 22(9):1011–1018

Ludwig W, Buffiere JY, Savelli S, Cloetens P (2003) Study of the interaction of a short fatigue crack with grain boundaries in a cast Al alloy using X-ray microtomography. Acta Mater 51(3):585–598

Labiche J-C, Mathon O, Pascarelli S, Newton MA, Ferre G, Curfs C, Vaughan G, Homs A, Fernandez Carreiras D (2007) Invited article: the fast readout low noise camera as a versatile X-ray detector for time resolved dispersive extended X-ray absorption fine structure and diffraction studies of dynamic problems in materials science, chemistry, and catalysis. Rev Sci Instrum 78(9):091301

Sinclair R, Preuss M, Maire E, Buffiere JY, Bowen P, Withers PJ (2004) The effect of fibre fractures in the bridging zone of fatigue cracked Ti-6Al-4V/SiC fibre composites. Acta Mater 52(6):1423–1438

Preuss M, Withers PJ, Maire E, Buffiere JY (2002) SiC single fibre full-fragmentation during straining in a Ti-6Al-4V matrix studied by synchrotron X-rays. Acta Mater 50(12):3175–3190

Breunig TM, Stock SR, Brown RC (1993) Simple load frame for in situ computed tomography and X-ray tomographic microscopy. Mater Eval 51:596–600

Buffiere JY, Ferrie E, Proudhon H, Ludwig W (2006) Three-dimensional visualisation of fatigue cracks in metals using high resolution synchrotron X-ray micro-tomography. Mater Sci Technol 22(9):1019–1024

Ferrie E, Buffiere JY, Ludwig W, Gravouil A, Edwards L (2006) Fatigue crack propagation: in situ visualization using X-ray microtomography and 3D simulation using the extended finite element method. Acta Mater 54(4):1111–1122

Verdu C, Adrien J, Buffiere JY (2008) Three-dimensional shape of the early stages of fatigue cracks nucleated in nodular cast iron. Mater Sci Eng, A 483:402–405

Birosca S, Buffiere JY, Garcia-Pastor FA, Karadge M, Babout L, Preuss M (2009) Three-dimensional characterization of fatigue cracks in Ti-6246 using X-ray tomography and electron backscatter diffraction. Acta Mater 57(19):5834–5847

Bellet D, Gorges B, Dallery A, Bernard P, Pereiro E, Baruchel J (2003) A 1300 K furnace for in situ X-ray microtomography. J Appl Crystallogr 36(Part 2):366–367

Coleou C, Lesaffre B, Brzoska JB, Ludwig W, Boller E (2001) Three-dimensional snow images by X-ray microtomography. In: Hutter K (ed) Annals of glaciology, vol 32, pp 75–81

http://www.esrf.eu/Industry/case-studies/icecream-tomography/icecream-tomography . Accessed Dec 2008

Deville S, Maire E, Bernard-Granger A, Lasalle G, Bogner A, Gauthier C, Leloup J, Guizard C (2009) Metastable and unstable cellular solidification of colloidal suspensions. Nat Mater 8:966–972

Flin F, Brzoska JB, Lesaffre B, Coleou CC, Pieritz RA (2004) Three-dimensional geometric measurements of snow microstructural evolution under isothermal conditions. In: Fohn PMB (ed) Annals of glaciology, vol 38, pp 39–44

Pieritz RA, Brzoska JB, Flin FD, Lesaffre B, Coleou U (2004) From snow X-ray microtomograph raw volume data to micromechanics modeling: first results. In: Fohn PMB (ed) Annals of glaciology, vol 38, pp 52–58

Terzi S, Salvo L, Suery M, Limodin N, Adrien J, Maire E, Pannier Y, Bornert M, Bernard D, Felberbaum M, Rappaz M, Boller E (2009) In situ X-ray tomography observation of inhomogeneous deformation in semi-solid aluminium alloys. Scr Mater 61(5):449–452

Masse JP, Salvo L, Rodney D, Brechet Y, Bouaziz O (2006) Influence of relative density on the architecture and mechanical behaviour of a steel metallic wool. Scr Mater 54(7):1379–1383

Toll S (1998) Packing mechanics of fiber reinforcements. Polym Eng Sci 38(8):1337–1350

Maire E, Carmona V, Courbon J, Ludwig W (2007) Fast X-ray tomography and acoustic emission study of damage in metals during continuous tensile tests. Acta Mater 55:6806–6815

Suresh S (1994) Fatigue of materials, 1st edn. Cambridge University Press, Cambridge

Buffiere JY, Savelli S, Jouneau PH, Maire E, Fougeres R (2001) Experimental study of porosity and its relation to fatigue mechanisms of model Al-Si7-Mg0.3 cast Al alloys. Mater Sci Eng, A 316(1–2):115–126

Ferrie E, Buffiere JY, Ludwig W (2005) 3d characterisation of the nucleation of a short fatigue crack at a pore in a cast al alloy using high resolution synchrotron microtomography. Int J Fatigue 27(10):1215–1220

Ludwig W, Reischig P, King A, Herbig M, Lauridsen EM, Johnson G, Marrow TJ, Buffiere JY (2009) Three-dimensional grain mapping by X-ray diffraction contrast tomography and the use of Friedel pairs in diffraction data analysis. Rev Sci Instrum 80(3):033905

Newman JC, Raju IS (1981) An empirical stress-intensity factor equation for the surface crack. Eng Fract Mech 15(1–2):185–192

Elber W (1970) Fatigue crack closure under cyclic tension. Eng Fract Mech 2:37–45

Nielsen SF, Poulsen HF, Beckmann F, Thorning C, Wert JA (2003) Measurements of plastic displacement gradient components in three dimensions using marker particles and synchrotron X-ray absorption microtomography. Acta Mater 51(8):2407–2415

Germaneau A, Doumalin P, Dupre JC (2007) 3D strain field measurement by correlation of volume images using scattered light: recording of images and choice of marks. Strain 43(3):207–218

Haldrup K, Nielsen SF, Wert JA (2008) A general methodology for full-field plastic strain measurements using X-ray absorption tomography and internal markers. Exp Mech 48(2):199–211

Barranger Y, Doumalin P, Dupre J-C, Germaneau A, Hedan S, Valle V (2009) Evaluation of three-dimensional and two-dimensional full displacement fields of a single edge notch fracture mechanics specimen, in light of experimental data using X-ray tomography. Eng Fract Mech 76(15):2371–2383

Bay BK, Smith TS, Fyhrie DP, Saad M (1999) Digital volume correlation: three-dimensional strain mapping using X-ray tomography. Exp Mech 39(3):217–226

Verhulp E, van Rietbergen B, Huiskes R (2004) A three-dimensional digital image correlation technique for strain measurements in microstructures. J Biomech 37(9):1313–1320

Roux S, Hild F, Viot P, Bernard D (2008) Three-dimensional image correlation from X-ray computed tomography of solid foam. Compos, Part A Appl Sci Manuf 39(8):1253–1265

Rethore J, Tinnes J-P, Roux S, Buffiere J-Y, Hild F (2008) Extended three-dimensional digital image correlation (X3D-DIC). C R Mec 336(8):643–649

Forsberg F, Mooser R, Arnold M, Hack E, Wyss P (2008) 3D micro-scale deformations of wood in bending: synchrotron radiation mcro CT data analyzed with digital volume correlation. J Struct Biol 164(3):255–262

Hild F, Maire E, Roux S, Witz JF (2009) Three-dimensional analysis of a compression test on stone wool. Acta Mater 57:3310–3320

Limodin N, Rethore J, Buffiere JY, Gravouil A, Hild F, Roux S (2009) Crack closure and stress intensity factor measurements in nodular graphite cast iron using three-dimensional correlation of laboratory X-ray microtomography images. Acta Mater 57(14):4090–4101

Lenoir N, Bornert M, Desrues J, Besuelle P, Viggiani G (2007) Volumetric digital image correlation applied to X-ray microtomography images from triaxial compression tests on argillaceous rock. Strain 43(3):193–205

Toda H, Sinclair I, Buffiere JY, Maire E, Khor KH, Gregson P, Kobayashi T (2004) A 3D measurement procedure for internal local crack driving forces via synchrotron X-ray microtomography. Acta Mater 52(5):1305–1317

Qu P, Toda H, Zhang H, Sakaguchi Y, Qian L, Kobayashi M, Uesugi K (2009) Local crack driving force analysis of a fatigue crack by a microstructural tracking method. Scr Mater 61(5):489–492

Kobayashi M, Toda H, Kawai Y, Ohgaki T, Uesugi K, Wilkinson D, Kobayashi T, Aoki Y, Nakazawa M (2008) High-density three-dimensional mapping of internal strain by tracking microstructural features. Acta Mater 56(10):2167–2181

Scheuerlein C, Di Michiel M, Haibel A (2007) On the formation of voids in internal tin Nb3Sn superconductors. Appl Phys Lett 90(13):132510

Pyzalla A, Camin B, Buslaps T, Di Michiel M, Kaminski H, Kottar A, Pernack A, Reimers W (2005) Simultaneous tomography and diffraction analysis of creep damage. Science 308(5718):92–95

Maire E, Owen A, Buffiere JY, Withers PJ (2001) A synchrotron X-ray study of a Ti/SiCf composite during in situ straining. Acta Mater 49(1):153–163

Salmon PL, Liu X, Sasov A (2009) A post-scan method for correcting artefacts of slow geometry changes during micro-tomographic scans. J X-ray Sci Technol 17(2):161–174