Implementation of the QRAPMASTER data analysis using dictionary matching and quantitative evaluation of the magnetization transfer effect
Tài liệu tham khảo
Wolff, 1989, Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo, Magn Reson Med, 10, 135, 10.1002/mrm.1910100113
Henkelman, 1993, Quantitative interpretation of magnetization transfer, Magn Reson Med, 29, 759, 10.1002/mrm.1910290607
Wood, 2020, Magnetization Transfer, 839
Ou, 2008, MT effects and T1 quantification in single-slice spoiled gradient echo imaging, Magn Reson Med, 59, 835, 10.1002/mrm.21550
Crooijmans, 2011, Influence of MT effects on T2 quantification with 3D balanced steady-state free precession imaging, Magn Reson Med, 65, 195, 10.1002/mrm.22326
van Gelderen, 2016, Effects of magnetization transfer on T1 contrast in human brain white matter, Neuroimage., 128, 85, 10.1016/j.neuroimage.2015.12.032
Liu, 2016, Rapid multicomponent relaxometry in steady state with correction of magnetization transfer effects, Magn Reson Med, 75, 1423, 10.1002/mrm.25672
Radunsky, 2019, Analysis of magnetization transfer (MT) influence on quantitative mapping of T2 relaxation time, Magn Reson Med, 82, 145, 10.1002/mrm.27704
Teixeira, 2019, Fast quantitative MRI using controlled saturation magnetization transfer, Magn Reson Med, 81, 907, 10.1002/mrm.27442
Teixeira, 2020, Controlled saturation magnetization transfer for reproducible multivendor variable flip angle T1 and T2 mapping, Magn Reson Med, 84, 221, 10.1002/mrm.28109
Warntjes, 2008, Rapid magnetic resonance quantification on the brain: optimization for clinical usage, Magn Reson Med, 60, 320, 10.1002/mrm.21635
Krauss, 2015, Accuracy and reproducibility of a quantitative magnetic resonance imaging method for concurrent measurements of tissue relaxation times and proton density, Magn Reson Imaging, 33, 584, 10.1016/j.mri.2015.02.013
Tanenbaum, 2017, Synthetic MRI for clinical neuroimaging: results of the magnetic resonance image compilation (MAGiC) prospective, multicenter, multireader trial, AJNR Am J Neuroradiol, 38, 1103, 10.3174/ajnr.A5227
Hagiwara, 2019, Linearity, Bias, Intrascanner repeatability, and interscanner reproducibility of quantitative multidynamic multiecho sequence for rapid simultaneous Relaxometry at 3 T: a validation study with a standardized phantom and healthy controls, Investig Radiol, 54, 39, 10.1097/RLI.0000000000000510
Nunez-Gonzalez, 2021, Accuracy and repeatability of QRAPMASTER and MRF-vFA, Magn Reson Imaging, 83, 196, 10.1016/j.mri.2021.09.004
Dixon, 1990, Incidental magnetization transfer contrast in standard multislice imaging, Magn Reson Imaging, 8, 417, 10.1016/0730-725X(90)90050-C
Melki, 1992, Magnetization transfer effects in multislice RARE sequences, Magn Reson Med, 24, 189, 10.1002/mrm.1910240122
Santyr, 1993, Magnetization transfer effects in multislice MR imaging, Magn Reson Imaging, 11, 521, 10.1016/0730-725X(93)90471-O
Weigel, 2010, Investigation and modeling of magnetization transfer effects in two-dimensional multislice turbo spin echo sequences with low constant or variable flip angles at 3 T, Magn Reson Med, 63, 230, 10.1002/mrm.22145
Hashimoto, 2012, Development of a pulse programmer for magnetic resonance imaging using a personal computer and a high-speed digital input–output board, Rev Sci Instrum, 83, 10.1063/1.4711132
Hashimoto, 2014, Comparison of analog and digital transceiver systems for MR imaging, Magn Reson Med Sci, 13, 285, 10.2463/mrms.2013-0114
Kose, 2017, BlochSolver: a GPU-optimized fast 3D MRI simulator for experimentally compatible pulse sequences, J Magn Reson, 281, 51, 10.1016/j.jmr.2017.05.007
Pauly, 1991, Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm, IEEE Trans Med Imaging, 10, 53, 10.1109/42.75611
Kose, 2019, A fast GPU-optimized 3D MRI simulator for arbitrary k-space sampling, Magn Reson Med Sci, 18, 208, 10.2463/mrms.mp.2018-0022
Ma, 2013, Magnetic resonance fingerprinting, Nature., 495, 187, 10.1038/nature11971
Kose, 2020, An accurate dictionary creation method for MR fingerprinting using a fast Bloch simulator, Magn Reson Med Sci, 19, 247, 10.2463/mrms.tn.2018-0157
Graham, 1997, Understanding pulsed magnetization transfer, J Magn Reson Imaging, 7, 903, 10.1002/jmri.1880070520
Sled, 2001, Quantitative imaging of magnetization transfer exchange and relaxation properties in vivo using MRI, Magn Reson Med, 46, 923, 10.1002/mrm.1278
Morrison, 1995, A model for magnetization transfer in tissues, Magn Reson Med, 33, 475, 10.1002/mrm.1910330404
Stanisz, 2005, T1, T2 relaxation and magnetization transfer in tissue at 3T, Magn Reson Med, 54, 507, 10.1002/mrm.20605
Marty, 2016, Simultaneous muscle water T2 and fat fraction mapping using transverse relaxometry with stimulated echo compensation, NMR Biomed, 29, 431, 10.1002/nbm.3459