Implementation and evaluation of an iterative-based algorithm for automatic beam angle optimization in breast cancer treatment planning

Ying Guo1,2,3,4, Yang Zhong1,2,3,4, Lei Yu1,2,3,4, Kang Zhang5, Jiazhou Wang1,2,3,4, Weigang Hu1,2,3,4
1Department of Radiation Oncology, Fudan University Shanghai Cancer Center, Shanghai 200032, China
2Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032, China
3Shanghai Clinical Research Center for Radiation Oncology
4Shanghai Key Laboratory of Radiation Oncology, Shanghai, 200032, China
5United Imaging Healthcare, Shanghai, 20032, China

Tài liệu tham khảo

Sung, 2021, Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries, CA Cancer J Clin, 71, 209, 10.3322/caac.21660 Waks, 2019, Breast cancer treatment: A review, JAMA, 321, 288, 10.1001/jama.2018.19323 Haciislamoglu, 2015, Dosimetric comparison of left-sided whole-breast irradiation with 3DCRT, forward-planned IMRT, inverse-planned IMRT, helical tomotherapy, and volumetric arc therapy, Phys Med, 31, 360, 10.1016/j.ejmp.2015.02.005 Mansouri, 2014, Dosimetric evaluation of 3-D conformal and intensity-modulated radiotherapy for breast cancer after conservative surgery, Asian Pac J Cancer Prev, 15, 4727, 10.7314/APJCP.2014.15.11.4727 Jagsi, 2022, Comparative Effectiveness analysis of 3D-conformal radiation therapy versus intensity modulated radiation therapy (IMRT) in a prospective multicenter cohort of patients with breast cancer, Int J Radiat Oncol Biol Phys, 112, 643, 10.1016/j.ijrobp.2021.09.053 Karpf, 2019, Left breast irradiation with tangential intensity modulated radiotherapy (t-IMRT) versus tangential volumetric modulated arc therapy (t-VMAT): Trade-offs between secondary cancer induction risk and optimal target coverage, Radiat Oncol, 14, 156, 10.1186/s13014-019-1363-4 Jeulink, 2015, Is there a preferred IMRT technique for left-breast irradiation?, J Appl Clin Med Phys, 16, 5266, 10.1120/jacmp.v16i3.5266 Bortfeld, 2006, IMRT: A review and preview, Phys Med Biol, 51, R363, 10.1088/0031-9155/51/13/R21 Söderström, 1995, Which is the most suitable number of photon beam portals in coplanar radiation therapy?, Int J Radiat Oncol Biol Phys, 33, 151, 10.1016/0360-3016(95)00113-D Bortfeld, 1993, Optimization of beam orientations in radiation therapy: Some theoretical considerations, Phys Med Biol, 38, 291, 10.1088/0031-9155/38/2/006 Stein, 1997, Number and orientations of beams in intensity-modulated radiation treatments, Med Phys, 24, 149, 10.1118/1.597923 Pugachev, 2001, Role of beam orientation optimization in intensity-modulated radiation therapy, Int J Radiat Oncol Biol Phys, 50, 551, 10.1016/S0360-3016(01)01502-4 Wang, 2004, Development of methods for beam angle optimization for IMRT using an accelerated exhaustive search strategy, Int J Radiat Oncol Biol Phys, 60, 1325, 10.1016/j.ijrobp.2004.06.007 Bangert, 2010, Spherical cluster analysis for beam angle optimization in intensity-modulated radiation therapy treatment planning, Phys Med Biol, 55, 6023, 10.1088/0031-9155/55/19/025 Potrebko, 2008, Improving intensity-modulated radiation therapy using the anatomic beam orientation optimization algorithm, Med Phys, 35, 2170, 10.1118/1.2905026 Llacer, 2009, Non-coplanar automatic beam orientation selection in cranial IMRT: A practical methodology, Biology, 54, 1337 Pugachev A., Xing LJIJROBP. Pseudo beam's-eye-view as applied to beam orientation selection in intensity-modulated radiation therapy. 2001;51(5):1361-70. Djajaputra, 2003, Algorithm and performance of a clinical IMRT beam-angle optimization system, Phys Med Biol, 48, 3191, 10.1088/0031-9155/48/19/007 Yang, 2006, Beam orientation optimization for intensity-modulated radiation therapy using mixed integer programming, Phys Med Biol, 51, 3653, 10.1088/0031-9155/51/15/004 Wang, 2003, Optimization of beam orientations and beam weights for conformal radiotherapy using mixed integer programming, Phys Med Biol, 48, 4065, 10.1088/0031-9155/48/24/005 Li, 2005, A particle swarm optimization algorithm for beam angle selection in intensity-modulated radiotherapy planning, Phys Med Biol, 50, 3491, 10.1088/0031-9155/50/15/002 Yongjie, Li, Jonathan, Yao, Dezhong, Medicine YJPi, et al. Automatic beam angle selection in IMRT planning using genetic algorithm. 2004. Phys Med Biol. 49:1915-32 Wu, 2000, Selection and determination of beam weights based on genetic algorithms for conformal radiotherapy treatment planning, Biology, 45, 2547 Lim, 2012, A two-phase method for selecting IMRT treatment beam angles: Branch-and-Prune and local neighborhood search, Eur J Op Res, 217, 609, 10.1016/j.ejor.2011.09.038 Lim, 2014, A hybrid framework for optimizing beam angles in radiation therapy planning, Ann Op Res, 217, 357, 10.1007/s10479-014-1564-z Hoffmann, 2021, Optimal beam angle selection and knowledge-based planning significantly reduces radiotherapy dose to organs at risk for lung cancer patients, Acta Oncol, 60, 293, 10.1080/0284186X.2020.1856409 Yu, 2021, Commissioning of and preliminary experience with a new fully integrated computed tomography linac, J Appl Clin Med Phys, 22, 208, 10.1002/acm2.13313 van't Riet, 1997, A conformation number to quantify the degree of conformality in brachytherapy and external beam irradiation: Application to the prostate, Int J Radiat Oncol Biol Phys, 37, 731, 10.1016/S0360-3016(96)00601-3 Hodapp, 2012, [The ICRU Report 83: Prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT)], Strahlenther Onkol, 188, 97, 10.1007/s00066-011-0015-x Taylor, 2015, Cardiac side-effects from breast cancer radiotherapy, Clin Oncol (R Coll Radiol), 27, 621, 10.1016/j.clon.2015.06.007 Borger, 2007, Cardiotoxic effects of tangential breast irradiation in early breast cancer patients: The role of irradiated heart volume, Int J Radiat Oncol Biol Phys, 69, 1131, 10.1016/j.ijrobp.2007.04.042 Purdie, 2011, Automated planning of tangential breast intensity-modulated radiotherapy using heuristic optimization, Int J Radiat Oncol Biol Phys, 81, 575, 10.1016/j.ijrobp.2010.11.016 Zhao, 2012, Automated beam placement for breast radiotherapy using a support vector machine based algorithm, Med Phys, 39, 2536, 10.1118/1.3700736 Wang, 2019, Goal-driven beam setting optimization for whole-breast radiation therapy, Technol Caner Res treat, 18 Cho, 2004, Determining optimal two-beam axial orientations for heart sparing in left-sided breast cancer patients, Med Phys, 31, 111, 10.1118/1.1634391 Rudat, 2014, In vivo surface dose measurement using GafChromic film dosimetry in breast cancer radiotherapy: Comparison of 7-field IMRT, tangential IMRT and tangential 3D-CRT, Radiat Oncol, 9, 156, 10.1186/1748-717X-9-156 Popescu, 2006, Inverse-planned, dynamic, multi-beam, intensity-modulated radiation therapy (IMRT): A promising technique when target volume is the left breast and internal mammary lymph nodes, Med Dosim, 31, 283, 10.1016/j.meddos.2006.05.003 Thilmann, 2003, Number and orientation of beams in inversely planned intensity-modulated radiotherapy of the female breast and the parasternal lymph nodes, Am J Clin Oncol, 26, e136, 10.1097/01.coc.0000091354.75297.42 Bangert, 2013, Comparison of beam angle selection strategies for intracranial IMRT, Med Phys, 40, 10.1118/1.4771932 Cabrera, 2018, A matheuristic approach to solve the multiobjective beam angle optimization problem in intensity-modulated radiation therapy, Int Trans Op Res, 25, 243, 10.1111/itor.12241 Shi, 2022, Deep learning empowered volume delineation of whole-body organs-at-risk for accelerated radiotherapy, Nat Commun, 13, 6566, 10.1038/s41467-022-34257-x Hedden, 2021, Radiation therapy dose prediction for left-sided breast cancers using two-dimensional and three-dimensional deep learning models, Phys Med, 83, 101, 10.1016/j.ejmp.2021.02.021 Ahn, 2021, Deep learning method for prediction of patient-specific dose distribution in breast cancer, Radiat Oncol, 16, 154, 10.1186/s13014-021-01864-9 Jiang, 2022, Artificial intelligence-based automated treatment planning of postmastectomy volumetric modulated Arc radiotherapy, Front Oncol, 12 Marrazzo, 2019, Auto-planning for VMAT accelerated partial breast irradiation, Radiother Oncol, 132, 85, 10.1016/j.radonc.2018.11.006 Jin, 2013, A comparative dosimetric study for treating left-sided breast cancer for small breast size using five different radiotherapy techniques: Conventional tangential field, filed-in-filed, tangential-IMRT, multi-beam IMRT and VMAT, Radiat Oncol, 8, 89, 10.1186/1748-717X-8-89 Sakthivel, 2017, Estimating second malignancy risk in intensity-modulated radiotherapy and volumetric-modulated Arc therapy using a mechanistic radiobiological model in radiotherapy for carcinoma of left breast, J Med Phys, 42, 234, 10.4103/jmp.JMP_89_17