Impact of atrial rhythm on pulmonary vein signals in cryoballoon ablation – Sinus rhythm predicts real-time observation of pulmonary vein isolation

IJC Heart and Vasculature - Tập 23 - Trang 100353 - 2019
Alexander Pott1, Michael Baumhardt1, Karolina Weinmann1, Manuel Rattka1, Tilman Stephan1, Mirjam Keßler1, Carlo Bothner1, Kerstin Petscher1, Wolfgang Rottbauer1, Tillman Dahme1
1Department of Medicine II, Ulm University Medical Center, Ulm, Germany

Tài liệu tham khảo

Pott, 2016, Increased rate of observed real-time pulmonary vein isolation with third-generation short-tip cryoballoon, J. Interv. Card. Electrophysiol., 47, 333, 10.1007/s10840-016-0160-3 Mugnai, 2016, Improved visualisation of real-time recordings during third generation cryoballoon ablation: a comparison between the novel short-tip and the second generation device, J. Interv. Card. Electrophysiol., 46, 307, 10.1007/s10840-016-0114-9 Furnkranz, 2016, Procedural characteristics of pulmonary vein isolation using the novel third-generation cryoballoon, Europace, 18, 1795, 10.1093/europace/18.suppl_1.i169b Koektuerk, 2016, Cryoballoon ablation for pulmonary vein isolation in patients with atrial fibrillation: preliminary results using novel short-tip cryoballoon, J. Interv. Card. Electrophysiol., 47, 91, 10.1007/s10840-016-0134-5 Heeger, 2016, Short tip-big difference? First-in-man experience and procedural efficacy of pulmonary vein isolation using the third-generation cryoballoon, Clin. Res. Cardiol., 105, 482, 10.1007/s00392-015-0944-y Aryana, 2017, Heart Rhythm., 14, 1319, 10.1016/j.hrthm.2017.06.020 Chun, 2017, Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-T trial, Heart Rhythm., 14, 495, 10.1016/j.hrthm.2016.12.014 Ferrero-de-Loma-Osorio, 2017, Time-to-effect-based dosing strategy for cryoballoon ablation in patients with paroxysmal atrial fibrillation: results of the plusONE multicenter randomized controlled noninferiority trial, Circ. Arrhythm. Electrophysiol., 10, 10.1161/CIRCEP.117.005318 Pott, 2018, Time-to-isolation guided titration of freeze duration in 3rd generation short-tip cryoballoon pulmonary vein isolation - comparable clinical outcome and shorter procedure duration, Int. J. Cardiol., 255, 80, 10.1016/j.ijcard.2017.11.039 Reissmann, 2017, First insights into cryoballoon-based pulmonary vein isolation taking the individual time-to-isolation into account, Europace, 19, 1676, 10.1093/europace/euw233 Heeger, 2018, Time-to-effect guided pulmonary vein isolation utilizing the third-generation versus second generation cryoballoon: one year clinical success, Cardiol. J. Andrade, 2015, Pulmonary vein signal interpretation during cryoballoon ablation for atrial fibrillation, Heart Rhythm., 12, 1387, 10.1016/j.hrthm.2015.02.027 Lakhani, 2014, Recordings of diaphragmatic electromyograms during cryoballoon ablation for atrial fibrillation accurately predict phrenic nerve injury, Heart Rhythm., 11, 369, 10.1016/j.hrthm.2013.11.015 Mondesert, 2014, Clinical experience with a novel electromyographic approach to preventing phrenic nerve injury during cryoballoon ablation in atrial fibrillation, Circ. Arrhythm. Electrophysiol., 7, 605, 10.1161/CIRCEP.113.001238 Shah, 2009, Electrophysiological evaluation of pulmonary vein isolation, Europace, 11, 1423, 10.1093/europace/eup289 Reissmann, 2018, Does size matter? Cryoballoon-based pulmonary vein isolation using a novel 25-mm circular mapping catheter, Circ. J., 82, 666, 10.1253/circj.CJ-17-0956 Pott, 2019, Novel spiral mapping catheter facilitates observation of the time-to-pulmonary vein isolation during cryoballoon ablation, Heart Vessel., 34, 496, 10.1007/s00380-018-1254-x