Imaging simulations of an “OpenPET” geometry with shifting detector rings

Taiga Yamaya1, Taku Inaniwa2, Shinichiro Mori2, Takuji Furukawa2, Shinichi Minohara2, Eiji Yoshida1, Fumihiko Nishikido1, Kengo Shibuya1, Naoko Inadama1, Hideo Murayama1
1Molecular Imaging Center, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan
2Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Japan

Tóm tắt

Từ khóa


Tài liệu tham khảo

Yamaya T, Inaniwa T, Minohara S, Yoshida E, Inadama N, Nishikido F et al. A proposal of an open PET geometry. Phys Med Biol. 2008;53:757–73.

Orlov SS. Theory of three-dimensional reconstruction. 1. Conditions for a complete set of projections. Soviet Phys Crystallogr. 1976;20:312–4.

Tanaka E, Amo Y. A Fourier rebinning algorithm incorporating spectral transfer efficiency for 3D PET. Phys Med Biol. 1998;43:739–46.

Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data. IEEE Trans Med Imag. 1994;13:601–9.

Wong WH, Zhang Y, Liu S, Li H, Baghaei H, Ramirez R, et al. The initial design and feasibility study of an affordable high-resolution 100-cm long PET. Conf Rec 2007 IEEE Nucl Sci Sym and Med Imag Conf. 2007: M22–3

Enghardt W, Crespo P, Fiedler F, Hinz R, Parodi K, Pawelke J, et al. Charged hadron tumour therapy monitoring by means of PET. Nucl Inst Meth Phy Res A. 2004;525:284–8.

Iseki Y, Mizuno H, Futami Y, Tomitani T, Kanai T, Kanazawa M et al. Positron camera for range verification of heavy-ion radiotherapy. Nucl Inst Meth Phy Res A. 2003;515:840–9.

Nishio T, Ogino T, Nomura K, Uchida H. Dose-volume delivery guided proton therapy using beam ON-LINE PET system. Med Phys. 2006;33(11):4190–7.

Inaniwa T, Kohno T, Tomitani T, Urakabe E, Sato S, Kanazawa M, et al. Experimental determination of particle range and dose distribution in thick targets through fragmentation reactions of stable heavy ions. Phys Med Biol. 2006;51:4129–46.

Crespo P, Shakirin G, Enghardt W. On the detector arrangement for in-beam PET for hadron therapy monitoring. Phys Med Biol. 2006;51:2143–63.

Nishio T, Miyatake A, Inoue K, Gomi-Miyagishi T, Kohno R, Kameoka S, et al. Experimental verification of proton beam monitoring in a human body by use of activity image of positron-emitting nuclei generated by nuclear fragmentation reaction. Radiol Phys Technol. 2008;1:44–54.

Noda K, Furukawa T, Fujisawa T, Iwata Y, Kanai T, Kanazawa M, et al. New accelerator facility for carbon-ion cancer-therapy. J Radiat Res. 2007;48(Suppl):A43–54.

Tomitani T, Pawelke J, Kanazawa M, Yoshikawa K, Yoshida K, Sato M, et al. Washout studies of 11C in rabbit thigh muscle implanted by secondary beams of HIMAC. Phys Med Biol. 2003;48:875–89.

Mizuno H, Tomitani T, Kanazawa M, Kitagawa A, Pawelke J, Iseki Y, et al. Washout measurement of radioisotope implanted by radioactive beams in the rabbit. Phys Med Biol. 2003;48:2269–81.