Image-guided breast biopsy: state-of-the-art

Clinical Radiology - Tập 65 Số 4 - Trang 259-270 - 2010
Elizabeth O’Flynn1, A.R.M. Wilson, MJ Michell
1South East London Breast Screening Programme and National Breast Screening Training Centre, Kings College Hospital NHS Foundation Trust, London SE5 9RS, UK. [email protected]

Tóm tắt

Từ khóa


Tài liệu tham khảo

NHS

Maxwell, 2009, The Royal College of Radiolgists Breast Group breast imaging classification, Clin Radiol, 64, 624, 10.1016/j.crad.2009.01.010

Vizcaino, 2002, Short term follow up results in 795 nonpalpable probably benign lesions detected at screening mammography, Radiology, 19, 475

1998, vol. 12

Barreau, 2003, Psychological adjustment of short interval follow-up mammography: about 50 cases, Gynecol Obstet Fertil, 31, 629, 10.1016/S1297-9589(03)00175-9

Denton, 1999, Image-guided breast biopsy: analysis of pain and discomfort related to technique, Breast, 8, 257, 10.1054/brst.1999.0067

Kocjan, 2003, Fine needle aspiration cytology. Inadequate rates compromise success, Cytopathology, 14, 307, 10.1046/j.0956-5507.2003.00103.x

Kocjan, 2008, The role of breast FNAC in diagnosis and clinical management: a survey of current practice, Cytopathology, 19, 271, 10.1111/j.1365-2303.2008.00610.x

Hayes, 1991, Acute inflammation of the breast–the role of breast ultrasound in diagnosis and management, Clin Radiol, 44, 253, 10.1016/S0009-9260(05)80190-4

Pisano, 1998, Rate of insufficient samples for fine needle aspiration for nonpalpable breast lesions in a multicenter clinical trial: The Radiologic Diagnostic Oncology Group 5 Study, Cancer, 82, 678

Perry, 2001, Quality assurance in the diagnosis of breast disease. EUSOMA Working Party, Eur J Cancer, 37, 159, 10.1016/S0959-8049(00)00337-3

Parker, 1993, Ultrasound guided automated large-core breast biopsy, Radiology, 187, 506, 10.1148/radiology.187.2.8475299

Helbich, 1998, Evaluation of needle size for breast biopsy: comparison of 14-, 16- and 18-G biopsy needles, AJR Am J Roentgenol, 171, 59, 10.2214/ajr.171.1.9648764

Parker, 1991, Non-palpable breast lesions: stereotactic automated large-core biopsies, Radiology, 180, 403, 10.1148/radiology.180.2.1648757

Helbich, 2004, Stereotactic and ultrasound-guided breast biopsy, Eur Radiol, 14, 383, 10.1007/s00330-003-2141-z

Helbich, 1997, Co-axial technique: approach to breast core biopsies, Radiology, 203, 684, 10.1148/radiology.203.3.9169689

Rich, 1999, Stereotactic 14-G core biopsy of non-palpable breast cancer: what is the relationship between the number of core samples taken and the sensitivity for detection of malignancy?, Clin Radiol, 54, 384, 10.1053/crad.1999.0199

Brenner, 1996, Percutaneous core biopsy of the breast: effect of operator experience and number of samples on diagnostic accuracy, AJR Am J Roentgenol, 166, 341, 10.2214/ajr.166.2.8553943

Liberman, 1994, Stereotactic 14-G breast biopsy: how many core biopsy specimens are needed?, Radiology, 192, 793, 10.1148/radiology.192.3.8058949

Sauer, 2005, Ultrasound guided large core needle biopsy of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification, Br J Cancer, 92, 231, 10.1038/sj.bjc.6602303

Doyle, 2005, Can the radiologist accurately predict the adequacy of sampling when performing ultrasound-guided core biopsy of BIRADS category 4 and 5 lesions detected on screening mammography?, Clin Radiol, 60, 999, 10.1016/j.crad.2005.05.002

Wallis, 2007, Guidelines from the European Society of Breast Imaging for diagnostic interventional breast procedures, Eur Radiol, 17, 581, 10.1007/s00330-006-0408-x

Bagnall, 2000, When have mammographic calcifications been adequately sampled at needle core biopsy?, Clin Radiol, 55, 548, 10.1053/crad.1999.0483

Liberman, 1998, US-guided core breast biopsy: use and cost-effectiveness, Radiology, 208, 717, 10.1148/radiology.208.3.9722851

Pijnappel, 2004, Diagnostic accuracy for different strategies of image-guided breast intervention in cases of non-palpable breast lesions, Br J Cancer, 90, 595, 10.1038/sj.bjc.6601559

Cho, 2005, Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods, Korean J Radiol, 6, 102, 10.3348/kjr.2005.6.2.102

Memarsadeghi, 2003, Value of 14-gauge ultrasound-guided large-core needle biopsy of breast lesions: own results in comparison with the literature, Rofo, 175, 374, 10.1055/s-2003-37822

Jackman, 1997, Needle-localised breast biopsy: why do we fail?, Radiology, 204, 677, 10.1148/radiology.204.3.9280243

Dillon, 2005, The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer with analysis of false-negative cases, Ann Surg, 242, 701, 10.1097/01.sla.0000186186.05971.e0

Schueller, 2008, US-guided 14-gauge core-needle breast biopsy: results of a validation study in 1352 cases, Radiology, 248, 406, 10.1148/radiol.2482071994

Diaz, 1999, Are malignant cells displaced by large-gauge needle core biopsy of the breast?, AJR Am J Roentgenol, 173, 1303, 10.2214/ajr.173.5.10541110

Hoorntje, 2004, Tumour cell displacement after 14G breast biopsy, Eur J Surg Oncol, 30, 520, 10.1016/j.ejso.2004.03.001

Liberman, 1995, Impact of stereotactic core breast biopsy on cost of diagnosis, Radiology, 195, 633, 10.1148/radiology.195.3.7753986

Liberman, 2000, Clinical management issues in percutaneous core breast biopsy, Radiol Clin North Am, 38, 791, 10.1016/S0033-8389(05)70201-3

Hung, 2009, Minimally invasive technology in the management of breast disease, Breast Cancer, 16, 23, 10.1007/s12282-008-0072-x

Liberman, 1998, Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy, Radiology, 208, 251, 10.1148/radiology.208.1.9646821

Burbank, 1997, Stereotactic breast biopsy: comparison of 14- and 11-gauge Mammotome probe performance and complication rate, Am Surg, 63, 988

Parker, 1997, Performing breast biopsy with a directional, vacuum-assisted biopsy instrument, Radiographics, 17, 1233, 10.1148/radiographics.17.5.9308112

Salem, 2009, Pain and complications of directional vacuum-assisted stereotactic biopsy: comparison of the Mammotome and Vacora techniques, Eur J Radiol, 72, 295, 10.1016/j.ejrad.2008.07.015

Simon, 2000, Accuracy and complication rates of US-guided vacuum-assisted core breast biopsy: initial results, Radiology, 215, 694, 10.1148/radiology.215.3.r00jn37694

Grady, 2005, Ultrasound-guided, vacuum-assisted, percutaneous excision of breast lesions: an accurate technique in the diagnosis of atypical ductal hyperplasia, J Am Coll Surg, 201, 14, 10.1016/j.jamcollsurg.2005.02.025

Cassano, 2007, Ultrasound-guided vacuum-assisted core breast biopsy: experience with 406 cases, Breast Cancer Res Treat, 102, 103, 10.1007/s10549-006-9305-x

Schueller, 2008, Accuracy of ultrasound-guided, large core needle breast biopsy, Eur Radiol, 18, 1761, 10.1007/s00330-008-0955-4

Zuiani, 2007, Stereotactic vacuum-assisted breast biopsy: results, follow-up and correlation with radiological suspicion, Radiol Med, 112, 304, 10.1007/s11547-007-0143-7

Pfarl, 2002, Stereotactic 11-G vacuum-assisted breast biopsy: a validation study, AJR Am J Roentgenol, 179, 1503, 10.2214/ajr.179.6.1791503

Burak, 2000, Vacuum-assisted stereotactic breast biopsy: histologic underestimation of malignant lesions, Arch Surg, 135, 700, 10.1001/archsurg.135.6.700

Lourenco, 2007, Stereotactic breast biopsy: comparison of histologic underestimation rates with 11- and 9-gauge vacuum-assisted breast biopsy, AJR Am J Roentgenol, 189, W275, 10.2214/AJR.07.2165

Liberman, 2001, Learning curve for stereotactic breast biopsy: how many cases are enough?, AJR Am J Roentgenol, 176, 721, 10.2214/ajr.176.3.1760721

Alonso-Bartolome, 2004, Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision: utility and cost study in probably benign lesions, Acta Radiol, 45, 390, 10.1080/02841850410005633

Cusumano, 2008, Percutaneous tissue acquisition: a treatment for breast cancer? Vacuum-assisted biopsy devices are not indicated for extended tissue removal, Eur J Cancer Prev, 17, 323, 10.1097/CEJ.0b013e3283048e0f

Kim, 2007, Breast lesions with imaging-histologic discordance during US-guided 14G automated core biopsy: can the directional vacuum-assisted removal replace the surgical excision? Initial findings, Eur Radiol, 17, 2376, 10.1007/s00330-007-0603-4

Grady, 2008, Long-term outcome of benign fibroadenomas treated by ultrasound-guided percutaneous excision, Breast J, 14, 275, 10.1111/j.1524-4741.2008.00574.x

Bonaventure, 2007, Benign papilloma: is US-guided vacuum-assisted breast biopsy an alternative to surgical biopsy?, J Radiol, 88, 1165, 10.1016/S0221-0363(07)89928-8

Chaveron, 2009, Clip migration after stereotactic macrobiopsy and presurgical localization: technical considerations and tricks, J Radiol, 90, 31, 10.1016/S0221-0363(09)70075-7

Yazici, 2006, Scar formation after stereotactic vacuum-assisted core biopsy of benign breast lesions, Clin Radiol, 61, 619, 10.1016/j.crad.2006.03.008

Zagouri, 2008, Vacuum-assisted breast biopsy: more cores, more scars?, Clin Radiol, 63, 736, 10.1016/j.crad.2007.11.023

Smathers, 2000, Advanced breast biopsy instrumentation device: percentages of lesion and surrounding tissue removed, AJR Am J Roentgenol, 175, 801, 10.2214/ajr.175.3.1750801

Hanna, 2005, The use of stereotactic excisional biopsy (ABBI) in the management of invasive breast cancer, World J Surg, 29, 1490, 10.1007/s00268-005-7828-7

Doridot, 2005, Stereotactic radioguided surgery by SiteSelect for subclinical mammographic lesions, Ann Surg Oncol, 12, 181, 10.1245/ASO.2005.01.004

Denton, 2000, Use of the site percutaneous breast biopsy device, Breast, 9, 107, 10.1054/brst.1999.0063

Fine, 2006, Percutaneous radiofrequency-assisted excision of fibroadenomas, Am J Surg, 192, 545, 10.1016/j.amjsurg.2006.06.011

Sie, 2006, Multicenter evaluation of the breast lesion excision system, a percutaneous, vacuum-assisted, intact-specimen breast biopsy device, Cancer, 107, 945, 10.1002/cncr.22090

Jung, 2004, Tissue harmonic imaging (THI) and contrast harmonic imaging (CHI) for sonographically guided vacuum-assisted biopsy of mammographically occult breast tumours, Rofo, 176, 1416, 10.1055/s-2004-813534

Cha, 2007, Characterisation of benign and malignant solid breast masses: comparison of conventional ultrasound and tissue harmonic imaging, Radiology, 242, 63, 10.1148/radiol.2421050859

Huber, 2002, Real time spatial compound imaging in breast ultrasound, Ultrasound Med Biol, 28, 155, 10.1016/S0301-5629(01)00490-2

Surry, 2002, The development and evaluation of a three-dimensional ultrasound-guided breast biopsy apparatus, Med Image Anal, 6, 301, 10.1016/S1361-8415(02)00087-7

Liberman, 2002, Percutaneous image-guided core breast biopsy, Radiol Clin North Am, 40, 483, 10.1016/S0033-8389(01)00011-2

Floery, 2006, MRI-guided percutaneous biopsy of breast lesions: materials, techniques, success rates, and management in patients with suspected radiologic–pathologic mismatch, Magn Reson Imaging Clin N Am, 14, 411, 10.1016/j.mric.2006.10.002

Kuhl, 1999, Dynamic breast MR imaging: are signal intensity time course data useful for differential diagnosis of enhancing lesions?, Radiology, 211, 101, 10.1148/radiology.211.1.r99ap38101

Boetes, 1997, False negative MR imaging of malignant breast tumours, Eur Radiol, 7, 1231, 10.1007/s003300050281

LaTrenta, 2003, Breast lesions detected with MR imaging: utility and histopathologic importance of identification with ultrasound, Radiology, 227, 856, 10.1148/radiol.2273012210

Viehweg, 2002, MR-guided interventional breast procedures considering vacuum biopsy in particular, Eur J Radiol, 42, 32, 10.1016/S0720-048X(01)00479-X

Britton, 2009, Use of ultrasound-guided axillary node core biopsy in staging of early breast cancer, Eur Radiol, 19, 561, 10.1007/s00330-008-1177-5