Hypothetical mortality risk associated with spiral computed tomography of the maxilla and mandible

European Journal of Oral Sciences - Tập 104 Số 5-6 - Trang 503-510 - 1996
Karl Dula1,2, R. Mini3, P.F. van der Stelt1, Jörg Thomas Lambrecht4,2, Paul Schneeberger3, Daniel Buser2
1Department of Oral Radiology, School of Dentistry, Academic Center for Dentistry Amsterdam, Amsterdam, The Netherlands
2Department of Oral Surgery, Section of Dental Radiology and Diagnostic Stomatology, School of Dental Medicine, University of Berne, Berne, Switzerland
3Department of Radiooncology, Division of Medical Radiation Physics, School of Medicine, University of Berne, Berne, Switzerland
4Department for Oral Surgery, Oral Radiology and Oral Medicine, School of Dentistry, University of Basle, Basle, Switzerland

Tóm tắt

In the present study, dose measurements have been conducted following examination of the maxilla and mandible with spiral computed tomography (CT). The measurements were carried out with 2 phantoms, a head and neck phantom and a full body phantom. The analysis of applied thermoluminescent dosimeters yielded radiation doses for organs and tissues in the head and neck region between 0.6 and 16.7 mGy when 40 axial slices and 120 kV/165 mAs were used as exposure parameters. The effective dose was calculated as 0.58 and 0.48 mSv in the maxilla and mandible, respectively. Tested methods for dose reduction showed a significant decrease of radiation dose from 40 to 65%. Based on these results, the mortality risk was estimated according to calculation models recommended by the Committee on the Biological Effects of Ionizing Radiations and by the International Commission on Radiological Protection. Both models resulted in similar values. The mortality risk ranges from 46.2×10‐6 for 20‐year‐old men to 11.2×10−6 for 65‐year‐old women. Using 2 methods of dose reduction, the mortality risk decreased by ∼ 50 to 60% to 19.1×10−6 for 20‐year‐old men and 5.5×10−6 for 65‐year‐old women. It can be concluded that a CT scan of the maxillofacial complex causes a considerable radiation dose when compared with conventional radiographic examinations. Therefore, a careful indication for this imaging technique and dose reduction methods should be considered in daily practice.

Từ khóa


Tài liệu tham khảo

10.14219/jada.archive.1990.0231

Ten Bruggenkate CM, 1993, Haemorrhage of the floor of the mouth resulting from lingual perforation during implant placement: A clinical report, Int J Oral Maxillofac Implants, 8, 329

Tetsch P, 1987, Schädigungen des N. alv. inf. durch Implantation im Unterkieferseitenzahnbereich, Z Zahnärztl Implantol, 3, 53

10.1016/S0278-2391(96)90113-5

Boyne PJ, 1980, Grafting of the maxillary sinus floor with autogenous marrow and bone, J Oral Surg, 38, 613

Schwarz M., 1987, Computed tomography. Part 1. Preoperative assessment of the mandible for endosseous implant surgery, Int J Oral Maxillofac Implants, 2, 137

Schwarz M., 1987, Computed tomography: Part II. Preoperative assessment of the maxilla for endosseous implant surgery, Int J Oral Maxillofac Implants, 2, 143

Wishan M., 1988, Computed tomography as an adjunct in dental implant surgery, Int J Periodontics Restorative Dent, 8, 30

Delbalso A, 1994, Role of diagnostic imaging in evaluation of the dental implant patient, Radio-graphics, 14, 699

James R., 1991, Computer tomography applications in implant dentistry, J Oral Implantol, 17, 10

10.1259/dmfr.24.3.8617386

De Lussanet De La Sabloniłre RM, 1985, CT‐scanning in palatoschizis, Acta Morphol Neerl Scand, 23, 289

10.1259/dmfr.24.1.8593910

Imhof K., 1992, Dental‐CT: Ein neues Programm zur Planung und Ueberprfung von Kieferimplantaten, Electromedica, 60, 26

Dula K., 1994, Computertomographie/Orale Implantologie. Dental‐CT®: Ein Programm zur computertomographischen Darstellung der Kiefer. Grundlagen und Aufnahmetechnik, Schweiz Monatsschr Zahnmed, 104, 451

Icrp Publication 60, 1990, 1990 Recommendations of the International Commission on Radiological protection

International Atomic Energy Agency., 1987, An international code of practice‐technical report series no. 277

10.1088/0031-9155/33/10/006

Knight R., 1994, Proceedings. International Atomic Energy Agency, International Symposium on Measurement Assurance in Dosimetry 1993, 361

Ma C., 1994, Proceedings. International Atomic Energy Agency International Symposium on Measurement Assurance in Dosimetry 1993, 371

Nahum A, 1994, Proceedings. International Atomic Energy Agency International Symposium on Measurement Assurance in Dosimetry 1993, 451

Committee On The Biologic Effects Of Ionizing Radiations., 1991, Health effects of exposure to low levels of ionizing radiation

10.1001/jama.219.7.864

10.1259/dmfr.1978.0001

10.1016/0030-4220(88)90077-1

PorettiG MiniR. GaravagliaG IonescoF. OttP FeuzJ.The determination of bone marrow dose resulting from diagnostic X‐ray examinations. In:DrexlerG EriskatH SchibillaH:Radiation protection. Commission of the European Communities. EUR 7438 EN 1981.

Icrp Publication 23., 1975, Report of the Task Group on Reference man

Boswick JA., 1987, The art and science of burn care

10.1148/radiology.195.2.7724783

Icrp Publication 26., 1977, Recommendations of the International Commission on Radiological protection

10.1002/1097-0142(197502)35:2<555::AID-CNCR2820350240>3.0.CO;2-G

10.1016/S0140-6736(74)92592-6

10.1016/0030-4220(92)90334-M

10.1259/dmfr.22.1.8508935

Clark D, 1990, Radiation absorbed from dental implant radiography, a comparison of linear tomography, ct‐scan, and panoramic and intra‐oral techniques, J Oral Implantol, 16, 156

Dula K., 1996, Computertomographie/Orale Implantologie. Dental‐CT® Programm zur computertomographischen Darstellung der Kiefer. Indikationen zur präimplantologischen Abklärung, Schweiz Monatsschr Zahnmed, 106, 13