Hilbert fractal inspired dipoles for passive RF shimming in ultra-high field MRI

Tania S. Vergara Gomez1,2, Marc Dubois3,2, Kaizad Rustomji4, Elodie Georget4, Tryfon Antonakakis4, Alexandre Vignaud5, Stanislas Rapacchi1, Olivier M. Girard3, Frank Kober3, Stefan Enoch2, Redha Abdeddaim2
1Aix Marseille Univ, CNRS, CRMBM, Marseille, France
2Aix Marseille Univ, CNRS, Centrale Marseille, Institut Fresnel, Institut Marseille Imaging, Marseille, France
3Aix-Marseille Univ, CNRS, CRMBM, Marseille, France
4Multiwave Imaging, Marseille, France
5CEA, DRF/Joliot/Neurospin, Université Paris-Saclay & CNRS, Gif-sur-Yvette Cedex, France

Tài liệu tham khảo

Yang, 2002, Analysis of wave behavior in lossy dielectric samples at high field, Magn. Reson. Med.: Off. J. Int. Soc. Magn. Reson. Med., 47, 982, 10.1002/mrm.10137 B.L. Beck, K.A. Jenkins, K. Padgett, J.R. Fitzsimmons, S.J. Blackband, Observation of B1 inhomogeneities on large biological samples at 11.1 T, in: Proceedings of the 11th Annual Meeting of ISMRM, 2003, p. 716. L.L. Wald, G.C. Wiggins, A. Potthast, C.J. Wiggins, C. Triantafyllou, Design considerations and coil comparisons for 7 T brain imaging, in: Proceedings of the 13th Annual Meeting of ISMRM, 2005, p. 921. Yang, 2006, Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials, J. Magn. Reson. Imaging: Off. J. Int. Soc. Magn. Reson. Med., 24, 197, 10.1002/jmri.20603 Webb, 2011, Dielectric materials in magnetic resonance, Concepts Magn. Reson. Part A, 38, 148, 10.1002/cmr.a.20219 Neves, 2018, Compressed perovskite aqueous mixtures near their phase transitions show very high permittivities: new prospects for high‐field MRI dielectric shimming, Magn. Reson. Med., 79, 1753, 10.1002/mrm.26771 Vaidya, 2018, Improved detection of fMRI activation in the cerebellum at 7T with dielectric pads extending the imaging region of a commercial head coil, J. Magn. Reson. Imaging, 48, 431, 10.1002/jmri.25936 Dubois, 2018, Kerker effect in ultrahigh-field magnetic resonance imaging, Phys. Rev. X, 8 M. Dubois, L. Leroi, Z. Raolison, R. Abdeddaim, T. Antonakakis, J. de Rosny, G. Tayeb, et al., Enhancement of transmit and receive efficiencies with hybridized meta-atom in 7 T head coil, in: Proceedings of the 27th Annual Meeting of ISMRM, 2019, p. 1491. Schmidt, 2017, Flexible and compact hybrid metasurfaces for enhanced ultra high field in vivo magnetic resonance imaging, Sci. Rep., 7, 1, 10.1038/s41598-017-01932-9 Ibrahim, 2001, Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator, Magn. Reson. Imaging, 19, 1339, 10.1016/S0730-725X(01)00404-0 Vaughan, 2006, 9.4 T human MRI: preliminary results, Magn. Reson. Med.: Off. J. Int. Soc. Magn. Reson. Med., 56, 1274, 10.1002/mrm.21073 Wang, 2008, B1 homogenization in MRI by multilayer coupled coils, IEEE Trans. Med. Imaging, 28, 551, 10.1109/TMI.2008.2006523 K. Lakshmanan, M. Cloos, G.C. Wiggins, R. Brown, Improving B1 excitation in head apex by combining birdcage coil with crossed dipole elements, in: Proceedings of the 21st Annual Meeting of ISMRM, 2013, p. 2754. Hong, 2014, New design concept of monopole antenna array for UHF 7 T MRI, Magn. Reson. Med., 71, 1944, 10.1002/mrm.24844 G. Chen, M. Cloos, D. Sodickson, G. Wiggins, A 7 T 8 channel transmit-receive dipole array for head imaging: dipole element and coil evaluation, in: Proceedings of the 22nd Annual Meeting of ISMRM, 2010, p. 621. Paška, 2018, A rigid, stand‐off hybrid dipole, and birdcage coil array for 7 T body imaging, Magn. Reson. Med., 80, 822, 10.1002/mrm.27048 Clément, 2019, A human cerebral and cerebellar 8–channel transceive RF dipole coil array at 7 T, Magn. Reson. Med., 81, 1447, 10.1002/mrm.27476 Clément, 2019, A combined 32–channel receive‐loops/8–channel transmit‐dipoles coil array for whole‐brain MR imaging at 7 T, Magn. Reson. Med., 82, 1229, 10.1002/mrm.27808 Hernandez, 2020, Computational evaluation for improving the| B1+ field in deep brain and cerebellum using a combination of a birdcage coil and a dipole antenna array., J. Electromagn. Waves Appl., 1 Ullmann, 2005, Experimental analysis of parallel excitation using dedicated coil setups and simultaneous RF transmission on multiple channels, Magn. Reson. Med.: Off. J. Int. Soc. Magn. Reson. Med., 54, 994, 10.1002/mrm.20646 Setsompop, 2008, Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 T with eight channels, Magn. Reson. Med.: Off. J. Int. Soc. Magn. Reson. Med., 59, 908, 10.1002/mrm.21513 Lattanzi, 2009, Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations, Magn. Reson. Med.: Off. J. Int. Soc. Magn. Reson. Med., 61, 315, 10.1002/mrm.21782 Teeuwisse, 2012, Quantitative assessment of the effects of high‐permittivity pads in 7 T MRI of the brain, Magn. Reson. Med., 67, 1285, 10.1002/mrm.23108 O’Brien, 2014, Dielectric pads and low‐adiabatic pulses: complementary techniques to optimize structural T1w whole‐brain MP2RAGE scans at 7 T, J. Magn. Reson. Imaging, 40, 804, 10.1002/jmri.24435 Teeuwisse, 2012, Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate‐based dielectric, Magn. Reson. Med., 67, 912, 10.1002/mrm.24176 A. Raaijmakers, O. Ipek, D. Klomp, H. Kroeze, B. van de Bank, V. Boer, N. van den Berg, et al., High-field imaging at low SAR: Tx/Rx prostate coil array using radiative elements for efficient antenna-patient power transfer, in: Proceedings of the 18th Annual Meeting of ISMRM, 2010, p. 48. Raaijmakers, 2011, Design of a radiative surface coil array element at 7 T: the single‐side adapted dipole antenna, Magn. Reson. Med., 66, 1488, 10.1002/mrm.22886 Raaijmakers, 2016, Dipole antennas for ultrahigh‐field body imaging: a comparison with loop coils, NMR Biomed., 29, 1122, 10.1002/nbm.3356 G.C. Wiggins, B. Zhang, R. Lattanzi, G. Chen, D.K. Sodickson, The electric dipole array: an attempt to match the ideal current pattern for central SNR at 7 T, in: Proceedings of the 20th Annual Meeting of ISMRM, 2012, p. 541. M. Dubois, L. Leroi, Z. Raolison, R. Abdeddaim, T. Antonakakis, J. de Rosny, G. Tayeb, et al., Passive RF shimming for 7 T head coil with hybridized meta-atom: in vivo investigation, in: Proceedings of the 28th Annual Meeting of ISMRM, 2020, p. 4093. K. Lakshmanan, M. Cloos, G.C. Wiggins, R. Brown, Improving B1 excitation in head apex by combining birdcage coil with crossed dipole elements, in: Proceedings of the 21st Annual Meeting of ISMRM, 2013, p. 2754. Raaijmakers, 2016, The fractionated dipole antenna: a new antenna for body imaging at 7 T, Magn. Reson. Med., 75, 1366, 10.1002/mrm.25596 A. Sadeghi-Tarakameh, A. Torrado-Carvajal, R.L. Lagore, S. Moen, X. Wu, G. Adriany, Y. Eryaman, et al., Toward human head imaging at 10.5 T using an eight-channel transmit/receive array of bumped fractionated dipoles, in: Proceedings of the 27th Annual Meeting of ISMRM, 2019, p. 430. W. Lee, M. Cloos, D.K. Sodickson, G.C. Wiggins, Parallel transceiver array design using the modified folded dipole for 7 T body applications, in: Proceedings of the 21st Annual Meeting ISMRM, 2013, p. 292. Krzysztofik, 2013, Fractal geometry in electromagnetics applications-from antenna to metamaterials, Microw. Rev., 19 Anguera, 2020, Fractal antennas: an historical perspective, Fractal Fract., 4, 3, 10.3390/fractalfract4010003 Motovilova, 2018, Hilbert curve-based metasurface to enhance sensitivity of radio frequency coils for 7-T MRI, IEEE Trans. Microw. Theory Tech., 67, 615, 10.1109/TMTT.2018.2882486 Nicolson, 1970, Measurement of the intrinsic properties of materials by time-domain techniques, IEEE Trans. Instrum. Meas., 19, 377, 10.1109/TIM.1970.4313932 Weir, 1974, Automatic measurement of complex dielectric constant and permeability at microwave frequencies, Proc. IEEE, 62, 33, 10.1109/PROC.1974.9382 Smith, 2005, Electromagnetic parameter re-trieval from inhomogeneous metamaterials, Phys. Rev. E, 71, 10.1103/PhysRevE.71.036617 Abdeddaim, 2011, Realizing a negative index metamaterial by con-trolling hybridization of trapped modes, Phys. Rev. B, 83, 10.1103/PhysRevB.83.033101 A. Amadon, F. Mauconduit, A. Vignaud, N. Boulant, Slice profile corrections in the XFL (magnetization-prepared turbo-FLASH) B1-mapping sequence, in: Proceedings of the 23th Annual Meeting ISMRM, 2015, p. 2377. Anguera, 2003, The fractal Hilbert monopole: a two‐dimensional wire, Microw. Opt. Technol. Lett., 36, 102, 10.1002/mop.10687 2006 V. Radonić, G. Misković, V. Cmojević-Bengin, Fractal dipole antennas based on Hilbert curves with different line-to-spacing ratio, in: Proceedings of the 13th International Conference on Advanced Technologies, Systems and Services in Telecommunications (TELSIKS), IEEE, 2017, pp. 95–8. S. Ha, W.W. Roeck, O. Nalcioglu, U.S. Patent No. 9,784,806, U.S. Patent and Trademark Office, Washington, DC, 2017. O.M. Dona-Lemus, N.B. Konyer, M.D. Noseworthy, Micro-strip surface coils using fractal geometry for 129Xe lung imaging applications, in: Proceedings of the 26th Annual Meeting ISMRM, 2018, p. 2377. Frass-Kriegl, 2019, Multi-loop radio frequency coil elements for magnetic resonance imaging: theory, simulation and experimental investigation, FrP, 7, 237 Haines, 2010, New high dielectric constant materials for tailoring the B1+ distribution at high magnetic fields, J. Magn. Reson., 203, 323, 10.1016/j.jmr.2010.01.003 Snaar, 2011, Improvements in high‐field localized MRS of the medial temporal lobe in humans using new deformable high‐dielectric materials, NMR Biomed., 24, 873, 10.1002/nbm.1638 O’Reilly, 2016, Practical improvements in the design of high permittivity pads for dielectric shimming in neuroimaging at 7 T, J. Magn. Reson., 270, 108, 10.1016/j.jmr.2016.07.003 Pendry, 1999, Magnetism from conductors and enhanced nonlinear phenomena, IEEE Trans. Microw. Theory Tech., 47, 2075, 10.1109/22.798002 Buckner, 2000, Functional MRI evidence for a role of frontal and inferior temporal cortex in amodal components of priming, Brain, 123, 620, 10.1093/brain/123.3.620 Stoodley, 2012, Functional topography of the cerebellum for motor and cognitive tasks: an fMRI study, Neuroimage, 59, 1560, 10.1016/j.neuroimage.2011.08.065