Highly sensitive index of sympathetic activity based on time-frequency spectral analysis of electrodermal activity

Hugo F. Posada-Quintero1, John P. Florian2, Álvaro D. Orjuela-Cañón3, Ki H. Chon1
1University of Connecticut, Storrs, Connecticut
2Navy Experimental Diving Unit, Panama City, Florida; and
3Universidad Antonio Nariño, Bogotá, Colombia

Tóm tắt

Time-domain indices of electrodermal activity (EDA) have been used as a marker of sympathetic tone. However, they often show high variation between subjects and low consistency, which has precluded their general use as a marker of sympathetic tone. To examine whether power spectral density analysis of EDA can provide more consistent results, we recently performed a variety of sympathetic tone-evoking experiments (43). We found significant increase in the spectral power in the frequency range of 0.045 to 0.25 Hz when sympathetic tone-evoking stimuli were induced. The sympathetic tone assessed by the power spectral density of EDA was found to have lower variation and more sensitivity for certain, but not all, stimuli compared with the time-domain analysis of EDA. We surmise that this lack of sensitivity in certain sympathetic tone-inducing conditions with time-invariant spectral analysis of EDA may lie in its inability to characterize time-varying dynamics of the sympathetic tone. To overcome the disadvantages of time-domain and time-invariant power spectral indices of EDA, we developed a highly sensitive index of sympathetic tone, based on time-frequency analysis of EDA signals. Its efficacy was tested using experiments designed to elicit sympathetic dynamics. Twelve subjects underwent four tests known to elicit sympathetic tone arousal: cold pressor, tilt table, stand test, and the Stroop task. We hypothesize that a more sensitive measure of sympathetic control can be developed using time-varying spectral analysis. Variable frequency complex demodulation, a recently developed technique for time-frequency analysis, was used to obtain spectral amplitudes associated with EDA. We found that the time-varying spectral frequency band 0.08–0.24 Hz was most responsive to stimulation. Spectral power for frequencies higher than 0.24 Hz were determined to be not related to the sympathetic dynamics because they comprised less than 5% of the total power. The mean value of time-varying spectral amplitudes in the frequency band 0.08–0.24 Hz were used as the index of sympathetic tone, termed TVSymp. TVSymp was found to be overall the most sensitive to the stimuli, as evidenced by a low coefficient of variation (0.54), and higher consistency (intra-class correlation, 0.96) and sensitivity (Youden's index > 0.75), area under the receiver operating characteristic (ROC) curve (>0.8, accuracy > 0.88) compared with time-domain and time-invariant spectral indices, including heart rate variability.

Từ khóa


Tài liệu tham khảo

10.1152/ajpheart.1985.249.4.H867

10.1111/j.1469-8986.1976.tb03088.x

Boucsein W, 2012, Psychophysiology, 49, 1017, 10.1111/j.1469-8986.2012.01384.x

10.1111/j.1748-1716.1986.tb07848.x

Brod J, 1959, Clin Sci, 18, 269

10.1113/jphysiol.1957.sp005839

10.1109/TBME.2009.2019766

10.1177/1932296814545669

10.1038/hr.2011.162

Crider A, 1971, J Exp Res Personal, 5, 145

10.1152/ajpregu.00246.2009

10.2466/pms.2000.91.2.515

10.1111/j.1748-1716.1972.tb05157.x

10.1172/JCI113138

10.1161/01.HYP.11.1.3

10.1136/bmj.285.6346.916

10.1152/japplphysiol.00466.2013

10.1016/B978-0-444-52902-2.00007-2

Garafova A, 2014, Physiol Res Acad Sci Bohemoslov, 63, S459

10.1063/1.1147748

Gil E, 2010, Conf Proc IEEE Eng Med Biol Soc, 2010, 3579

Goldstein DS, 1995, Stress, Catecholamines, and Cardiovascular Disease, 234

10.1097/00004872-199917060-00001

10.1097/00004872-199816110-00010

10.1148/radiology.143.1.7063747

10.1109/TITS.2005.848368

Hoeldtke RD, 1983, J Lab Clin Med, 101, 772

10.1097/00005792-197501000-00002

10.1098/rspa.1998.0193

10.1007/s10286-008-0506-8

10.1161/01.CIR.44.3.413

Kopin IJ, 1985, Pharmacol Rev, 37, 333

10.1016/j.lfs.2015.06.011

10.1161/01.CIR.84.2.482

Marple SL, 1987, Digital Spectral Analysis: With Applications

Mathias CJ, 2014, Autonomic Failure: a Textbook of Clinical Disorders of the Autonomic Nervous System, 169

10.1046/j.1460-9592.2001.00296.x

10.1037/1082-989X.1.1.30

10.1016/S0001-2998(78)80014-2

10.1016/j.jpsychores.2004.11.004

10.1109/TBME.2002.805478

Moses ZB, 2007, Conf Proc IEEE Eng Med Biol Soc, 2007, 644

10.1007/s10439-016-1606-6

10.1111/j.1440-1681.2005.04218.x

10.1080/00221309.1976.9711614

10.1161/01.CIR.59.4.637

10.1016/0002-9149(91)90264-L

10.1093/ajh/hpt131

10.1016/j.ijcard.2004.09.013

Schwartz PJ, 1996, Neurology, 46, 873, 10.1212/WNL.46.2.420

10.1109/TITB.2009.2036164

10.1152/ajprenal.00114.2009

10.1007/s10286-009-0517-0

10.1037/h0054651

10.1007/s10286-014-0250-1

10.1093/oxfordjournals.eurheartj.a014868

10.1016/0021-9681(61)90094-7

10.1152/physrev.1979.59.4.919

10.1155/2011/935364

10.1088/0967-3334/35/7/1319

10.1007/s10439-005-9035-y

10.1007/BF00283745

10.1152/japplphysiol.01152.2002

10.1002/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO;2-3

10.1016/0165-1781(81)90006-8

10.1152/ajpregu.00362.2007

Zhong Y, 2006, Conf Proc IEEE Eng Med Biol Soc, 1, 6438, 10.1109/IEMBS.2006.260815