Highly integrated workflows for exploring cardiovascular conditions: Exemplars of precision medicine in Alzheimer's disease and aortic dissection

Morphologie - Tập 103 - Trang 148-160 - 2019
J.C. Vardakis1, M. Bonfanti2,3, G. Franzetti2, L. Guo2, T. Lassila1, M. Mitolo4, M. Hoz de Vila1, J.P. Greenwood5,6, G. Maritati7,8, D. Chou9, Z.A. Taylor10, A. Venneri11, S. Homer-Vanniasinkam2,6,12, S. Balabani2, A.F. Frangi1, Y. Ventikos2, V. Diaz-Zuccarini2,3
1Centre for Computational Imaging & Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, UK
2Department of Mechanical Engineering, University College London, Torrington Place, London WC1E 7JE, UK
3Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Department of Medical Physics and Biomedical Engineering, University College London, UK
4Functional MR Unit, Policlinico S. Orsola e Malpighi, Department of Biomedical and NeuroMotor Sciences (DiBiNeM), Bologna, Italy
5Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, UK
6Leeds Teaching Hospitals NHS Trust, Leeds, UK
7Ospedale “A. Perrino”, Brindisi, Italy
8Azienda Ospedaliera San Camillo-Forlanini, Rome, Italy
9Department of Mechanical Engineering, National Central University, Taoyuan County, Taiwan
10Centre for Computational Imaging & Simulation Technologies in Biomedicine (CISTIB), School of Mechanical Engineering, University of Leeds, UK
11Department of Neuroscience, Medical School, University of Sheffield, UK
12University of Warwick Medical School & University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK

Tài liệu tham khảo

Viceconti, 2019, From bed to bench: how in silico medicine can help ageing research, Mech Ageing Dev, 177, 103, 10.1016/j.mad.2018.07.001 Patterson, 2018, World Alzheimer's Report 2018, Alzheimer's Disease International Tublin, 2019, Getting to the Heart of Alzheimer's Disease, Circ Res, 124, 142, 10.1161/CIRCRESAHA.118.313563 Tarasoff-Conway, 2015, Clearance systems in the brain-implications for Alzheimer disease, Nat Rev Neurol, 11, 457, 10.1038/nrneurol.2015.119 Ramanathan, 2015, Impaired vascular-mediated clearance of brain amyloid beta in Alzheimer's disease: the role, regulation and restoration of LRP1, Front. Aging Neurosci, 7, 136, 10.3389/fnagi.2015.00136 Gottesman, 2017, Association between midlife vascular risk factors and estimated brain amyloid deposition, JAMA, 317, 1443, 10.1001/jama.2017.3090 Roher, 2012, Cerebral blood flow in Alzheimer's disease, Vascular health and risk management, 8, 599, 10.2147/VHRM.S34874 Thomas, 2015, Post-mortem assessment of hypoperfusion of cerebral cortex in Alzheimer's disease and vascular dementia, Brain, 138, 1059, 10.1093/brain/awv025 de la Torre, 2004, Is Alzheimer's disease a neurodegenerative or a vascular disorder? Data, dogma, and dialectics, Lancet Neurol, 3, 184, 10.1016/S1474-4422(04)00683-0 Drachman, 2014, The amyloid hypothesis, time to move on: amyloid is the downstream result, not cause, of Alzheimer's disease, Alzheimer's Dement, 10, 372, 10.1016/j.jalz.2013.11.003 Austin, 2011, Effects of hypoperfusion in Alzheimer's disease, J Alzheimer's Dis, 26, 123, 10.3233/JAD-2011-0010 Mazza, 2011, Primary cerebral blood flow deficiency and Alzheimer's disease: shadows and lights, J Alzheimers Dis, 23, 375, 10.3233/JAD-2010-090700 Ruitenberg, 2005, Cerebral hypoperfusion and clinical onset of dementia: the Rotterdam Study, Ann Neurol, 57, 789, 10.1002/ana.20493 Bondi, 2017, Alzheimer's disease: past, present, and future, J Int Neuropsycholo Soc, 23, 818, 10.1017/S135561771700100X Iadecola, 2004, Neurovascular regulation in the normal brain and in Alzheimer's disease, Nat Rev Neurosci, 5, 347, 10.1038/nrn1387 Louveau, 2017, Understanding the functions and relationships of the glymphatic system and meningeal lymphatics, J Clin Invest, 127, 3210, 10.1172/JCI90603 Da Mesquita, 2018, The meningeal lymphatic system: a new player in neurophysiology, Neuron, 100, 375, 10.1016/j.neuron.2018.09.022 Bakker, 2019, Paravascular spaces: entry to or exit from the brain?, Exp Physiol, 104, 113, 10.1113/EP087424 Iliff, 2012, A paravascular pathway facilitates CSF flow through the brain parenchyma and the clearance of interstitial solutes, including amyloid β, Sci Transl Med, 4, 10.1126/scitranslmed.3003748 Kress, 2014, Impairment of paravascular clearance pathways in the aging brain, Ann Neurol, 76, 845, 10.1002/ana.24271 Xie, 2013, Sleep drives metabolite clearance from the adult brain, Science, 342, 373, 10.1126/science.1241224 Vardakis, 2019, Fluid-structure interaction for highly complex, statistically defined biological media: homogenisation and a 3D multi-compartmental poroelastic model for brain biomechanics, J Fluids Structures, 10.1016/j.jfluidstructs.2019.04.008 Di Marco, 2014, Modifiable lifestyle factors in dementia: a systematic review of longitudinal observational cohort studies, J Alzheimers Dis, 42, 119, 10.3233/JAD-132225 Thrumurthy, 2012, The diagnosis and management of aortic dissection, BMJ, 344 Nienaber, 2015, Management of acute aortic dissection, The Lancet, 385, 800, 10.1016/S0140-6736(14)61005-9 Erbel, 2014, 2014 ESC Guidelines on the diagnosis and treatment of aortic diseases, Eur Heart J, 35, 2873, 10.1093/eurheartj/ehu281 Trimarchi, 2019, Acute aortic dissections with entry tear in the arch: a report from the International Registry of Acute Aortic Dissection, J Thorac Cardiovasc Surg, 157, 66, 10.1016/j.jtcvs.2018.07.101 Kamman, 2017, Predictors of aortic growth in uncomplicated type B aortic dissection from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) database, J Vasc Surg, 65, 964, 10.1016/j.jvs.2016.09.033 Kamman, 2016, Contemporary management strategies for chronic type B aortic dissections: a systematic review, PLoS One, 10.1371/journal.pone.0154930 Xu, 2017, Hemodynamic parameters that may predict false-lumen growth in type-B aortic dissection after endovascular repair: a preliminary study on long-term multiple follow-ups, Med Eng Phys, 7 Xu, 2018, Coupled morphological–hemodynamic computational analysis of type B aortic dissection: a longitudinal study, Ann Biomed Eng, 26, 927, 10.1007/s10439-018-2012-z Romarowski, 2018, Patient-specific CFD modelling in the thoracic aorta with PC-MRI-based boundary conditions: a least-square three-element Windkessel approach, Int J Numer Method Biomed Eng, 34, 10.1002/cnm.3134 Westerhof, 2009, The arterial Windkessel, Med Biol Eng Comput, 47, 131, 10.1007/s11517-008-0359-2 Pirola, 2017, On the choice of outlet boundary conditions for patient-specific analysis of aortic flow using computational fluid dynamics, J Biomech, 60 Alimohammadi, 2015, Aortic dissection simulation models for clinical support: fluid-structure interaction vs. rigid wall models, Biomed Eng Online, 14 Biot, 1941, General theory of three-dimensional consolidation, J Appl Phys, 12, 155, 10.1063/1.1712886 Biot, 1955, Theory of elasticity and consolidation for a porous anisotropic solid, J Appl Phys, 26, 182, 10.1063/1.1721956 Terzaghi, 1925, Principle of soil mechanics, Eng News Record, A Series of Articles Guo, 2018, Subject-specific multi-poroelastic model for exploring the risk factors associated with the early stages of Alzheimer's disease, Interface Focus, 8, 10.1098/rsfs.2017.0019 Lassila, 2017, Screening for cognitive impairment by model-assisted cerebral blood flow estimation, IEEE Trans Biomed Eng, 65, 1654, 10.1109/TBME.2017.2759511 de Vila, 2018, 1726 Bonfanti, 2019, Patient-specific haemodynamic simulations of complex aortic dissections informed by commonly available clinical datasets, Med Eng Phys, 77, 45, 10.1016/j.medengphy.2019.06.012 Pant, 2014, A methodological paradigm for patient-specific multi-scale CFD simulations: from clinical measurements to parameter estimates for individual analysis, Int J Numer Method Biomed Eng, 30, 1614, 10.1002/cnm.2692 Bonfanti, 2018, A simplified method to account for wall motion in patient-specific blood flow simulations of aortic dissection: Comparison with fluid-structure interaction, Med Eng Phys, 58, 72, 10.1016/j.medengphy.2018.04.014 Bonfanti, 2017, Computational tools for clinical support: a multi-scale compliant model for haemodynamic simulations in an aortic dissection based on multi-modal imaging data, J R Soc Interface, 14, 10.1098/rsif.2017.0632 ANSYS. Inc., 2016, CFX-Solver theory guide, Release, 17 Boespflug, 2018, Targeted assessment of enlargement of the perivascular space in Alzheimer's Disease and vascular dementia subtypes implicates astroglial involvement specific to Alzheimer's disease, J Alzheimer's Dis, 66, 1587, 10.3233/JAD-180367 Chou, 2016, A fully dynamic multi-compartmental poroelastic system: Application to aqueductal stenosis, J Biomechan, 49, 2306, 10.1016/j.jbiomech.2015.11.025 Asgari, 2015, How astrocyte networks may contribute to cerebral metabolite clearance, Sci Rep, 5 Eidsvaag, 2018, Cerebral microvascular abnormalities in patients with idiopathic intracranial hypertension, Brain Res, 1686, 72, 10.1016/j.brainres.2018.02.017 Iadecola, 2013, The pathobiology of vascular dementia, Neuron, 80, 844, 10.1016/j.neuron.2013.10.008 Vardakis, 2016, Investigating cerebral oedema using poroelasticity, Medical Engineering and Physics, 38, 48, 10.1016/j.medengphy.2015.09.006 Vardakis, 2013, Exploring the efficacy of endoscopic ventriculostomy for hydrocephalus treatment via a multicompartmental poroelastic model of CSF transport: a computational perspective, PLoS ONE, 8, 10.1371/journal.pone.0084577 Thompson, 2019, An implicit discontinuous Galerkin method for modeling acute edema and resuscitation in the small intestine, Math Med Biol, 10.1093/imammb/dqz001 Soudah, 2015, Validation of numerical flow simulations against in vitro phantom measurements in different type B aortic dissection scenarios, Comput Methods Biomech Biomed Engin, 18, 805, 10.1080/10255842.2013.847095 Menichini, 2018, A computational model for false lumen thrombosis in type B aortic dissection following thoracic endovascular repair, J Biomech, 66, 36, 10.1016/j.jbiomech.2017.10.029 Osswald, 2017, Elevated wall shear stress in aortic type B dissection may relate to retrograde aortic type a dissection: a computational fluid dynamics pilot study, Eur J Vasc Endovasc Surg, 54, 324, 10.1016/j.ejvs.2017.06.012 Tsai, 2008, Tear size and location impacts false lumen pressure in an ex vivo model of chronic type B aortic dissection, J Vasc Surg, 47, 844, 10.1016/j.jvs.2007.11.059 Chen, 2013, A longitudinal study of Type-B aortic dissection and endovascular repair scenarios: computational analyses, Med Eng Phys, 35, 1321, 10.1016/j.medengphy.2013.02.006