Glucose monitoring: state of the art and future possibilities

Medical Engineering & Physics - Tập 18 Số 4 - Trang 273-288 - 1996
Ebtisam Wilkins1, Plamen Atanasov1
1Department of Chemical and Nuclear Engineering, University of New Mexico, Albuquerque, NM 87131 USA

Tóm tắt

Từ khóa


Tài liệu tham khảo

1982, 5, 1

1990, Diabetes control and complications trial (DCCT) update, Diabetes Care, 13, 427, 10.2337/diacare.13.4.427

Page, 1993, Blood glucose monitoring: does technology help?, Diabetic Med, 10, 793, 10.1111/j.1464-5491.1993.tb00168.x

Fischer, 1991, Fundamentals of glucose sensors, Diabetic Med, 8, 309, 10.1111/j.1464-5491.1991.tb01603.x

Pickup, 1985, Biosensors: a clinical perspective, Lancet, 2, 817, 10.1016/S0140-6736(85)90804-9

Clarke, 1987, Biosensors in process control, Phil Trans R Soc London, B316, 169, 10.1098/rstb.1987.0026

Karube, 1987, Biosensors in food industry, Food Biotechnol, 1, 147, 10.1080/08905438709549665

Pickup, 1993, Blood glucose and glycated haemoglobin measurement in hospital: which Method?, Diabetic Med, 10, 402, 10.1111/j.1464-5491.1993.tb00090.x

Kaiser, 1979, Laser absorption spectroscopy with an ATR prism-noninvasive in vitro determination of glucose, Horm Metab Res Supl Ser, 8, 30

Hall, 1992, Near-infrared spectrophotometry: a new dimension in clinical chemistry, Clin Chem, 38, 1623, 10.1093/clinchem/38.9.1623

Gries, 1994, Noninvasive blood glucose sensors based on near-infrared spectroscopy, Artificial Organs, 18, 439, 10.1111/j.1525-1594.1994.tb02230.x

Haaland, 1992, Reagentless near-infrared determination of glucose in whole blood using multivariable calibration, Applied Spectroscopy, 46, 1575, 10.1366/000370292789619232

Ward, 1992, Postprandial blood glucose determunation by quantitative mid-infrared spectroscopy, Applied Spectroscopy, 46, 959, 10.1366/0003702924124493

Robinson, 1992, Noninvasive glucose monitoring in diabetic patients: a preliminary evaluation, Clin Chem, 38, 1618, 10.1093/clinchem/38.9.1618

Hazen, 1994, Temperature-insensitive spectroscopic measurement of glucose in aqueous solutions, Applied Spectroscopy, 48, 477, 10.1366/000370294775268910

Marquardt, 1993, Near-infrared spectroscopic measurement of glucose in a protein matrix, Anal Chem, 65, 3271, 10.1021/ac00070a018

Small, 1993, Strategies for coupling digital filtering with partial least-squares regression: application to the determination of glucose in plasma by fourier transform near-infrared spectroscopy, Anal Chem, 65, 3279, 10.1021/ac00070a019

Marbach, 1993, Noninvasive blood glucose assay by near-infrared diffuse reflectance spectroscopy of the human inner lip, Applied Spectroscopy, 47, 875, 10.1366/0003702934415354

Kajiwara, 1993, Noninvasive measurement of blood glucose concentrations by analysing fourier transform infra-red absorbance spectra through oral mucosa, Med Biol Eng Comput, 31, S17, 10.1007/BF02446645

Van Heuvelen, 1987

Guibault, 1988, Non-invasive in vivo glucose measurements, Artificial Organs, 13, 172

Guilbault, 1994, Biosensors — New Orleans perspective

Karube, 1994

Vadgama, 1991, Chemical sensors and biosensors: nearer the patient, Pure & Appl Chem, 63, 1147, 10.1351/pac199163081147

Vadgama, 1992, Biosensors: recent trends: a review, Analyst, 117, 1657, 10.1039/an9921701657

Vadgama, 1993, Biosensors in clinical biochemistry, Ann Clin Biochem, 30, 337, 10.1177/000456329303000401

Pickup, 1984, Review — Technology and the diabetic patient, Med Biol Eng Comput, 22, 384, 10.1007/BF02447697

Turner, 1985, Diabetes mellitus: biosensors for research and management, Biosensors, 1, 85, 10.1016/0265-928X(85)85006-9

Pickup, 1993, In vivo glucose monitoring: sense and sensorbility, Diabetes Care, 16, 535, 10.2337/diacare.16.2.535

Clark, 1962, Electrode system for continuous monitoring in cardiovascular surgery, Ann NY Acad Sci, 102, 29, 10.1111/j.1749-6632.1962.tb13623.x

Updike, 1967, The enzyme electrode, Nature, 214, 986, 10.1038/214986a0

Clark, 1977, The characteristics of a new glucose sensor for use in artificial beta cell, Artif Organs, 1, 78, 10.1111/j.1525-1594.1977.tb00982.x

Clark, 1980, Stable continuous signal from blood glucose enzyme anode system, Artif Organs, 3, 272

Clark, 1982, Implanted electroenzymated glucose sensors, Diabetes Care, 5, 174, 10.2337/diacare.5.3.174

Clark, 1988, Long-term implantation of voltammetric oxidase/peroxidase glucose sensors in rat peritoneum, Methods in Enzymology, 137, 68, 10.1016/0076-6879(88)37008-4

Updike, 1979, Continuous glucose monitor based on an immobilized enzyme electrode detector, J Lab Clin Med, 93, 518

Updike, 1982, Implanting the glucose enzyme electrode: problems, progress and alternative solutions, Diabetes Care, 5, 207, 10.2337/diacare.5.3.207

Updike, 1988, Laboratory evaluation of new reusable blood glucose sensor, Diabetes Care, 11, 801, 10.2337/diacare.11.10.801

Zamzow, 1990, Development and evaluation of a wearable blood glucose monitor, Trans Am Soc Artif Internal Organs, 36, M588

Updike, 1994, Enzymatic blood glucose sensor: improved long-term performance in vitro and in vivo, J Am Soc Artif Internal Organs, 40, 157, 10.1097/00002480-199404000-00007

Gilligan, 1994, Evaluation of a subcutaneous glucose sensor out to 3 months in a dog model, Diabetes Care, 17, 882, 10.2337/diacare.17.8.882

Pfeiffer, 1987, On the way to automated (blood) glucose regulation in diabetes: the dark past, the grey present and the rosy future, Diabetologia, 30, 51, 10.1007/BF00274572

Pickup, 1987, Implantable glucose sensors: choosing the appropriate sensing strategy, Biosensors, 3, 335, 10.1016/0265-928X(87)80016-0

Shichiri, 1982, Wearable artificial endocrine pancreas with needle-type glucose sensor, Lancet, 20, 1129, 10.1016/S0140-6736(82)92788-X

Shichiri, 1983, Glycemic control in pancreatectomized dogs with a wearable artificial endocrine pancreas, Diabetologia, 24, 179, 10.1007/BF00250158

Shichiri, 1984, Closed loop glycemic control with a wearable artificial endocrine pancreas, Diabetes, 33, 1200, 10.2337/diabetes.33.12.1200

Shichiri, 1984, The development of wearable-type artificial endocrine pancreas and its usefulness in glycemic control of human diabetes mellitus, Biomed Biochim Acta, 43, 561

Shichiri, 1984, The glucose sensor: present and future, 177

Shichiri, 1985, Needle-type glucose sensor for wearable artificial endocrine pancreas, 197

Kondo, 1981, Trial of new vessel access type glucose sensor for implantable artificial pancreas in vivo, Trans Am Soc Artif Internal Organs, 27, 250

Kondo, 1982, A miniature glucose sensor implantable in the blood stream, Diabetes Care, 5, 218, 10.2337/diacare.5.3.218

Ito, 1986, Development of subcutaneous-type glucose sensor for implantable portable artificial pancreas, 271

Thevenot, 1982, Problems in adapting a glucose oxidase electrochemical sensor into an implantable glucose sensing device, Diabetes Care, 5, 184, 10.2337/diacare.5.3.184

Velho, 1987, The design and development of in vivo glucose sensor for an artificial endocrine pancreas, 390

Abel, 1984, Experience with implantable glucose sensors as a prequisite of an artificial beta cell, Biomed Biochim Acta, 43, 577

Bruckel, 1990, The glucose unitec ulm — a portable monitor for continuous blood glucose measurement, Horm Met Res, 22, 382

Shichiri, 1986, Telemetry glucose monitoring device with needle glucose sensor: a useful tool for blood glucose monitoring in diabetic individuals, Diabetes Care, 9, 298, 10.2337/diacare.9.3.298

Schoonen, 1990, Development of potentially wearable glucose sensor for patients with diabetes mellitus: design and in vitro evaluation, Biosensors & Bioelectronics, 5, 37, 10.1016/0956-5663(90)80025-9

Aalders, 1991, Development of a wearable glucose sensor: studies in healthy volunteers and in diabetic patients, Int J Artif Organs, 14, 102, 10.1177/039139889101400210

Schmidt, 1992, Calibration of a wearable glucose sensor, Int J Artif Organs, 15, 55, 10.1177/039139889201500110

Keck, 1991, Combination of microdialysis and glucosensor permits continuous (online) s.c. glucose monitoring in a patient operated device: I. in vitro evaluation, Horm Met Res, 23, 617, 10.1055/s-2007-1003769

Keck, 1992, Combination of microdialysis and glucosensor permits continuous (online) s.c. glucose monitoring in a patient operated device: II. evaluation in animals, Horm Met Res, 24, 492, 10.1055/s-2007-1003370

Meyerhoff, 1992, Online continuous monitoring of subcutaneous tissue glucose in men by combining portable glucosensor with microdialysis, Diabetologia, 35, 1087, 10.1007/BF02221686

Pfeiffer EF, Meyerhoff C, Bischof F, Keck FS, Kerner W. Online continuous monitoring of subcutaneous tissue glucose is feasible by combining portable glucosensor with microdialysis. Horm Met Res 993; 25: 121–124.

Keck, 1993, Registration of dissolved glucose in vitro and in vivo by a combined microdialysis/amperometric method, Sensors & Actuators B, 15–16, 435, 10.1016/0925-4005(93)85223-W

Moscone, 1992, Subcutaneous microdialysis probe coupled with glucose biosensor for in vivo continuous monitoring, Talanta, 39, 1039, 10.1016/0039-9140(92)80292-L

Mascini, 1992, In vivo continuous monitoring of glucose by microdialysis and a glucose biosensor, Sensors & Actuators B, 6, 143, 10.1016/0925-4005(92)80046-Z

Moscone, 1992, Microdialysis and glucose biosensor for in vivo monitoring, Ann Biol Clin, 50, 223

Palmisano, 1993, An interference-free biosensor based on glucose oxidase electrochemically immobilized in a non-conducting poly(pyrrole) film for continuous subcutaneous monitoring of glucose through microdialysis sampling, Biosensors & Bioelectronics, 8, 393, 10.1016/0956-5663(93)80023-I

Rebrin, 1992, Subcutaneous glucose monitoring by means of electrochemical sensors: fiction of reality, J Biomed Eng, 14, 33, 10.1016/0141-5425(92)90033-H

Reach, 1989, Artificial or bioartificial systems for the totally automatic treatment of diabetes mellitus: the gap between the dream and the reality, Diab Nutr Metab, 2, 165

Mascini, 1992, Biosensors for medical applications, Sensors & Actuators B, 6, 79, 10.1016/0925-4005(92)80034-U

Reach, 1992, Can continuous glucose monitoring be used for the treatment of diabetes, Anal Chem, 64, 381A, 10.1021/ac00030a001

Shichiri, 1988, Medical application of the glucose sensor and artificial pancreas, 1, 209

Claremont, 1987, In vivo chemical sensors and biosensors in clinical medicine, 357

Pickup, 1991, Glucose sensors and closed-loop insulin delivery, 126

Waxman, 1992, Implantable programable insulin pumps for the treatment of diabetes, Arch Surg, 127, 1032, 10.1001/archsurg.1992.01420090036006

Buchwald, 1992, Implantable pumps: resent progress and anticipated future advances, Trans Amer Soc Artif Internal Organs, 38, 772

Zoltobrocki, 1992, Insulin delivery by implantable pumps, Horm Metab Res Supl Ser, 26, 140

Scavini, 1992, Long term implantation of a new programmable implantable insulin oump, Artif Organs, 16, 518, 10.1111/j.1525-1594.1992.tb00335.x

Hall, 1990

Lerner, 1981, Development of an implantable glucose sensor, Artif Organs, 5, 743

Wilkins, 1989, Towards implantable glucose sensors: a review, J Biomed Eng, 11, 353, 10.1016/0141-5425(89)90096-4

Weibel, 1971, The glucose oxidase mechanism, J Biol Chem, 246, 2743, 10.1016/S0021-9258(18)62246-X

Turner, 1987

Bergveld, 1970, Development of an ion-selective solid-state device for neuro-physiologicsl measurements, IEEE Trans Biomed Eng, 17, 70, 10.1109/TBME.1970.4502688

Kell, 1990, Conductimetric and impedimetric devices, 125

Lammbrechts, 1992, Biosensors: Microelectrochemical Devices

Guilbault, 1973, An enzyme electrode for amperometric determination of glucose and lactate, Anal Chim Acta, 64, 439, 10.1016/S0003-2670(01)82476-4

Cass, 1984, Ferrocene mediated enzyme electrode for amperometric determination of glucose, Anal Chem, 56, 667, 10.1021/ac00268a018

Cenas, 1981, Biocatalytic oxidation of glucose on the conductive charge transfer complex, Bioelectrochem Bioenerget, 8, 103, 10.1016/0302-4598(81)85011-8

Gough, 1973, Enzyme electrodes, Science, 180, 380, 10.1126/science.180.4084.380

Gough, 1982, Progress towards a potentially implantable enzyme-based glucose sensor, Diabetes Care, 5, 190, 10.2337/diacare.5.3.190

Koudelka, 1986, Performance characteristics of a planar clark-type oxygen sensor, Sensors & Actuators, 9, 249, 10.1016/0250-6874(86)80025-7

Jobst, 1993, Thin-film clark-type oxygen sensor based on novel polymer membrane system for in vivo and biosensor applications, Biosensors & Bioelectronics, 8, 123, 10.1016/0956-5663(93)85024-I

Xie, 1993, Towards an implantable refillable glucose sensor based on oxygen electrode principles, Sensors & Actuators B, 17, 133

Atanasov, 1993, Glucose biosensor based on oxygen electrode. Part I: silastic coated polycarbonate membranes for biosensor application, Analytical Letters, 28, 1587, 10.1080/00032719308021482

Atanasov, 1993, Glucose biosensor based on oxygen electrode. Part II: long term operational stability of the rechargeable glucose biosensor, Analytical Letters, 26, 2079, 10.1080/00032719308017453

Atanasov, 1994, Development of biosensor for glucose monitoring, Biotechnol Bioeng, 43, 262, 10.1002/bit.260430310

Urban, 1994, Performance of integrated glucose and lactate thin-film microbiosensors for clinical analysers, Sensors & Actuators B, 18–19, 592, 10.1016/0925-4005(93)01095-L

Schalkhammer, 1994, Microfabriciated glucose, lactate, glutamate and glutamine thin-film biosensors, Sensors & Actuators B, 18–19, 587, 10.1016/0925-4005(93)01094-K

Leypoldt, 1984, Model of a two-substrate enzyme electrode for glucose, Anal Chem, 56, 2896, 10.1021/ac00278a063

Gough, 1985, A two-dimensional enzyme electrode for glucose, Anal Chem, 57, 2351, 10.1021/ac00289a042

Tse, 1987, Determination of the intrinsic kinetic constants of immobilized glucose oxidase and catalase, Biotechnol Bioeng, 29, 696, 10.1002/bit.260290606

Tse, 1987, Time dependent inactivation of immobilized glucose oxidase and catalase, Biotechnol Bioeng, 29, 705, 10.1002/bit.260290607

Lucisano, 1988, Transient response of the two-dimensional glucose sensor, Anal Chem, 60, 1272, 10.1021/ac00164a007

Churchouse, 1986, Studies on needle glucose electrodes, Anal Pros, 23, 146

Churchouse, 1986, Needle enzyme electrodes for biological studies, Biosensors, 2, 325, 10.1016/0265-928X(86)85022-2

Vadgama, 1988, The glucose enzyme electrode: is simple peroxide detection at a needle sensor acceptable, Horm Met Res Suppl Ser, 20, 20

Sternberg, 1988, Study and development of multilayer needle-type enzyme based glucose microsensors, Biosensors, 4, 27, 10.1016/0265-928X(89)80032-X

Wilson, 1992, Progress towards the development of an implantable sensor for glucose, Clin Chem, 38, 1613, 10.1093/clinchem/38.9.1613

Moatti-Sirat, 1992, Evaluating in vitro and in vivo the interference of ascorbate and acetaminophen on glucose detection by a needle-type glucose sensor, Biosensors & Bioelectronics, 7, 345, 10.1016/0956-5663(92)85030-E

Gernet, 1989, Fabrication and characterization of a planar electrochemical cell and its application as a glucose sensor, Sensors & Actuators, 18, 59, 10.1016/0250-6874(89)87025-8

Koudelka, 1989, Planar amperometric enzyme-based glucose microelectrode, Sensors & Actuators, 18, 157, 10.1016/0250-6874(89)87015-5

Weiss, 1988, An amperometric glucose sensor with combined enzyme layers, Horm Metab Res Supl Ser, 20, 23

Kerner, 1988, A potentially implantable enzyme electrode for amperometric measurement of glucose, Horm Metab Res Supl Ser, 20, 8

Fisher, 1982, A membrane combination for implantable glucose sensors. Measurements in undiluted biological fluids, Trans Am Soc Artif Internal Organs, 27, 245

Moussy, 1994, In vitro and in vivo performance and lifetime of perfluorinated ionomer coated glucose sensors after high-temperature curing, Anal Chem, 66, 3882, 10.1021/ac00094a007

Harrison, 1988, Characterization of perfluorsulfonic acid polymer coated enzyme electrode and a miniaturized integrated potentiostat for glucose analysis in whole blood, Anal Chem, 60, 2002, 10.1021/ac00170a003

Turner, 1990, A biocompatible for continuous in vivo glucose monitoring in whole blood, Sensors & Actuators B, 1, 561, 10.1016/0925-4005(90)80273-3

Moussy, 1993, Performance of subcutaneously implanted needle-type glucose sensor employing a novel trilayer coating, Anal Chem, 65, 2072, 10.1021/ac00063a023

Urban, 1991, Miniaturized thin-film biosensors using covalently immobilized glucose oxidase, Biosensors & Bioelectronics, 6, 555, 10.1016/0956-5663(91)80019-T

Urban, 1992, Miniaturized multi-enzyme biosensors integrated with pH-sensors on flexible polymer carriers for in vivo applications, Biosensors & Bioelectronics, 7, 733, 10.1016/0956-5663(92)85056-G

Genshow, 1988, Enzyme electrode for determining of glucose in whole blood, Clin Chem, 34, 1717, 10.1093/clinchem/34.9.1713

Schneider, 1990, Microminiature enzyme sensor for glucose and lactate, Sensors & Actuators B, 1, 565, 10.1016/0925-4005(90)80274-4

Kanapieniene, 1992, Miniature glucose biosenser with extended linearity, Sensors & Actuators B, 10, 37, 10.1016/0925-4005(92)80008-L

Claremont, 1986, Potentially-implantable, ferrocene mediated glucose sensor, J. Biomed Eng, 8, 272, 10.1016/0141-5425(86)90095-6

Claremont, 1986, Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs, Diabetologia, 29, 817, 10.1007/BF00873223

Pickup, 1988, Progress towards in vivo glucose sensing with a ferrocene-mediated amperometric enzyme electrode, Horm Metab Res Supl Ser, 20, 34

Claremont, 1988, Biosensors for continuous in vivo glucose monitoring, 740

Pickup, 1989, Potentially implantable amperometric glucose sensors with mediated electron transfer: improving the operating stability, Biosensors, 4, 109, 10.1016/0265-928X(89)80026-4

Pickup, 1989, In vivo molecular sensing in diabetes mellitus: an implantable glucose sensor with direct electron transfer, Diabetologia, 32, 213, 10.1007/BF00265097

Sakakida, 1990, Ferrocene-mediated glucose sensors for subcutaneous tissue glucose sensing, Artif Organs, 14, 28

Shihiri, 1991, Artificial endocrine pancreas — problems awaiting solution for long-term clinical applications of a glucose sensor, Frontiers Med Biol Eng, 3, 283

Sakakida, 1992, Development of a ferrocene-mediated needle-type glucose sensors as a measure of true subcutaneous tissue glucose concentrations, Artif Organs Today, 2, 145

Matthews, 1988, An amperometric needle-type glucose sensor tested in rats and man, Diabetic Med, 5, 248, 10.1111/j.1464-5491.1988.tb00978.x

Albery, 1985, Amperometric enzyme electrodes. Part 2: conducting organic salt as electrode materials for the oxidation of glucose oxidase, J Electroanal Chem, 194, 223, 10.1016/0022-0728(85)85006-3

Albery, 1986, An amperometric enzyme electrode for measuring changes in brain glucose, J Physiol, 382, 93P

Boutelle, 1987, An amperometric enzyme electrode for continuous monitoring of brain glucose in freely moving rat, Neurosci Lett, 72, 283, 10.1016/0304-3940(86)90527-6

Gough, 1986, Short term in vivo operation of a glucose sensor, Trans Amer Soc Artif Internal Organs, 32, 148

Conway, 1987, Long term in vitro operation of enzyme electrode based glucose sensor, Sensors & Actuators, 1, 305, 10.1016/0250-6874(87)80070-7

Johnson, 1992, In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue, Biosensors & Bioelectronics, 7, 709, 10.1016/0956-5663(92)85053-D

Xie, 1991, Rechargeable glucose electrodes for long-term implantation, J Biomed Eng, 13, 375, 10.1016/0141-5425(91)90017-2

Xie, 1991, Performances of potentially implantable rechargeable glucose sensor in vitro at body temperature, Biomed Instrum & Technol, 25, 393

Vadgama, 1989, The needle glucose electrode: in vitro performance and optimization for implantation, Biomed Biochim Acta, 48, 935

Shichiri, 1987, Needle-type glucose sensor and its clinical applications, 409

Shichiri, 1988, In vivo characteristics of needle-type glucose sensor — measurement of subcutaneous glucose concentration in human volunteers, Horm Metab Res Supl Ser, 20, 17

Shichiri, 1988, Needle-type glucose sensor, Methods in Enzymology, 137, 326, 10.1016/0076-6879(88)37031-X

Ikeda, 1990, Needle-type glucose sensor based titanium oxide type on oxygen electrode, Artif Organs, 14, 24

Ikeda, 1991, Artificial pancreas: development of a new needle-type glucose sensor based on oxygen electrode with a new concept, Artif Organs Today, 1, 303

Chen, 1992, A biocompatible needle-type glucose sensor based on platinum electroplated carbon electrode, Appl Biochem Biotech, 36, 211, 10.1007/BF02921780

Chen, 1992, Amperometric needle-type glucose sensor based on a modified platinum electrode with diminished response to interfering materials, Anal Chim Acta, 265, 5, 10.1016/0003-2670(92)85148-Y

Chen, 1993, Biocompatible needle-type glucose sensor with potential for use in vivo, Electroanalysis, 5, 269, 10.1002/elan.1140050402

Chen, 1993, Biocompatible membranes with special functions for biosensors applications, Membrane, 18, 207, 10.5360/membrane.18.207

Velho, 1989, Working potential stability of a needle-type subcutaneous glucose sensor: influence of needle material upon in vitro and in vivo sensor performances, Diabetes, 38, 164, 10.2337/diabetes.38.2.164

Bindra, 1991, Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring, Anal Chem, 63, 1692, 10.1021/ac00017a008

Abdel-Hamid, 1994, Development of a needle-type glucose biosensor, Anal Letters, 27, 1453, 10.1080/00032719408006382

Hashiguchi, 1994, Development of a miniaturized glucose monitoring system by combining a needle-type glucose sensor with microdialysis sampling method, Diabetes Care, 5, 387, 10.2337/diacare.17.5.387

Show, 1991, In vitro testing of a simply constructed highly stable glucose sensor suitable for implantation in diabetic patient, Biosensors & Bioelectronics, 6, 401, 10.1016/0956-5663(91)87004-U

Shichiri, 1990, Membrane design for extending the long-life of implantable glucose sensor, Diabetes Nutrition & Metabolism, 2, 303

Bruckel, 1989, In vivo measurement of subcutaneous glucose concentrations with an enzymatic glucose sensor and wick method, Klin Wochenschr, 67, 491, 10.1007/BF01721675

Moatti-Sirat, 1992, Towards continuous glucose monitoring: in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue, Diabetologia, 35, 224, 10.1007/BF00400921

Poitout, 1993, A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit, Diabetologia, 36, 658, 10.1007/BF00404077

Zhang, 1993, In vivo and in vitro evaluation of oxygen effects on a glucose oxidase based implantable glucose sensor, Anal Chim Acta, 281, 513, 10.1016/0003-2670(93)85009-9

Hu, 1993, A needle-type enzyme-based lactate sensor for in vivo monitoring, Anal Chim Acta, 281, 503, 10.1016/0003-2670(93)85008-8

Sternberg, 1994, Comments on subcutaneous glucose monitoring, Diabetologia, 37, 540, 10.1007/BF03035164

Muller, 1986, Continuously monitored subcutaneous glucose concentration by using implanted enzyme electrodes (German), Biomed Biochim Acta, 45, 769

Gough, 1988, Issues related to in vitro operation of potentially implantable enzyme electrode glucose sensors, Horm Metab Res Supl Ser, 20, 30

McKean, 1988, A telemetry instrumentation system for chronically implanted glucose and oxygen sensors, IEEE Trans Biomed Eng, 35, 526, 10.1109/10.4581

Ertefai, 1989, Physiologic preparation for studying the response of subcutaneously implanted glucose and oxygen sensors, J Biomed Eng, 11, 362, 10.1016/0141-5425(89)90097-6

Armor, 1990, Application of chronic intravascular blood glucose sensor in dogs, Diabetes, 39, 1519, 10.2337/diabetes.39.12.1519

Koudelka, 1989, In vivo response of microfabricated glucose sensors to glycemia changes in normal rats, Biomed Biochim Acta, 48, 953

Koudelka, 1991, In vivo behaviour of hypodermically implanted microfabricated glucose sensors, Biosensors & Bioelectronics, 6, 31, 10.1016/0956-5663(91)85005-H

Strike, 1993, Electrodeposition of glucose oxidase for the fabrication of miniature sensors, Sensors & Actuators B, 13–14, 61, 10.1016/0925-4005(93)85323-3

Koudelka-Hep, 1993, Miniature electrochemical glucose biosensors, Anal Chim Acta, 281, 461, 10.1016/0003-2670(93)85003-3

Fabietti, 1991, Wearable system for acquisition, processing and storage of the signal from amperometric glucose sensors, Int J Artif Organs, 14, 175, 10.1177/039139889101400310

Bobbioni-Harsch, 1993, Lifespan of subcutaneous glucose sensors and the performances during glycemia changes in rats, J Biomed Eng, 15, 547, 10.1016/0141-5425(93)90058-7

Koudelka, 1992, A microfabricated glucose sensor: fabrication, characterization in vitro and in vivo performance and related problems, Advances in Biosensors, 2, 131

Fischer, 1987, Assessment of subcutaneous glucose concentration: validation of the wick technique as a reference for implanted electrochemical sensor in normal and diabetic dogs, Diabetologia, 30, 940, 10.1007/BF00295878

Abel, 1988, The GOD-H2O2-electrode as an approach to implantable glucose sensors, Horm Metab Res Supl Ser, 20, 26

Brunstein, 1989, Preparation and validation of implantable electrodes for measurement of oxygen and glucose, Biomed Biochim Acta, 48, 911

von Woedtke, 1989, In situ calibration of implanted electrochemical glucose sensors, Biomed Biochim Acta, 48, 943

Fisher, 1989, Oxygen tension at the subcutaneous implantation site of glucose sensors, Biomed Biochim Acta, 48, 965

Rebrin, 1989, Automated feed-back control of subcutaneous glucose concentration in diabetic dogs, Diabetologia, 32, 573, 10.1007/BF00285330

Wilkins, 1993, A rechargeable glucose sensor—long term activity and performance, Biomed Instrum & Technol, 27, 325

Wilkins, 1995, Integrated implantable device for long-term glucose monitoring, Biosensors & Bioelectronics, 10, 485, 10.1016/0956-5663(95)96894-5

Schmidt, 1993, Glucose concentration in subcutaneous extracellular space, Diabetes Care, 16, 695, 10.2337/diacare.16.5.695

Velho, 1988, In vivo calibration of a subcutaneous glucose sensor for determination of subcutaneous glucose kinetics, Diab Nutr Metab, 1, 227

Velho, 1989, Strategies for calibrating a subcutaneous glucose sensor, Biomed Biochim Acta, 48, 957