Frequency-controlled wireless shape memory polymer microactuator for drug delivery application

Springer Science and Business Media LLC - Tập 19 - Trang 1-10 - 2017
M. A. Zainal1, A. Ahmad1, M. S. Mohamed Ali1
1Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Skudai, Malaysia

Tóm tắt

This paper reports the wireless Shape-Memory-Polymer actuator operated by external radio frequency magnetic fields and its application in a drug delivery device. The actuator is driven by a frequency-sensitive wireless resonant heater which is bonded directly to the Shape-Memory-Polymer and is activated only when the field frequency is tuned to the resonant frequency of heater. The heater is fabricated using a double-sided Cu-clad Polyimide with much simpler fabrication steps compared to previously reported methods. The actuation range of 140 μm as the tip opening distance is achieved at device temperature 44 °C in 30 s using 0.05 W RF power. A repeatability test shows that the actuator’s average maximum displacement is 110 μm and standard deviation of 12 μm. An experiment is conducted to demonstrate drug release with 5 μL of an acidic solution loaded in the reservoir and the device is immersed in DI water. The actuator is successfully operated in water through wireless activation. The acidic solution is released and diffused in water with an average release rate of 0.172 μL/min.

Tài liệu tham khảo

S.K. Ahn, P. Deshmukh, R.M. Kasi, Macromolecules 43, 7330 (2010) P. Basset, A. Kaiser, P. Bigotte, D. Collard, and L. Buchaillot, in Micro Electro Mechanical Systems, 2002. The Fifteenth IEEE International Conference (2002), pp. 606–609 S. Chen, J. Hu, H. Zhuo, Y. Zhu, Mater. Lett. 62, 4088 (2008) F.P. Du, E.Z. Ye, W. Yang, T.H. Shen, C.Y. Tang, X.L. Xie, X.P. Zhou, W.C. Law, Composites Part B Engineering 68, 170 (2015) R. Farra, N.F. Sheppard Jr., L. McCabe, R.M. Neer, J.M. Anderson, J.T. Santini Jr., M.J. Cima, R. Langer, Sc. Transl. Med. 4 (2012) X.Q. Feng, G.Z. Zhang, Q.M. Bai, H.Y. Jiang, B. Xu, H.J. Li, Macromolecular Materials Engineering 301, 125 (2016) A. Fick, Annalender Physik 170, 59 (1855) J. Fong, Z. Xiao, K. Takahata, Lab Chip – Miniaturisation Chemistry Biology 15, 1050 (2015) S.Y. Gu, S.P. Jin, X.F. Gao, J. Mu, Smart Mater. Struct. 25 (2016) L.H. Han, S. Chen, Sensors Actuators, A: Physical 121, 35 (2005) J. Li, W.R. Rodgers, T. Xie, Polymer 52, 5320 (2011) R. Lo, P.Y. Li, S. Saati, R.N. Agrawal, M.S. Humayun, E. Meng, Biomed. Microdevices 11, 959 (2009) H. Lu, Y. Yao, L. Lin, Pigment Resin Technology 43, 26 (2014) D.J. Maitland, M.F. Metzger, D. Schumann, A. Lee, T.S. Wilson, Lasers Surgery Medicine 30, 1 (2002) H. Meng and G. Li, Polymer(United Kingdom) 54, 2199 (2013). M.S. Mohamed Ali, K. Takahata, Sensors Actuators A: Physical 163, 363 (2010) M.S. Mohamed Ali, K. Takahata, J. Micromech. Microeng. 21 (2011) J.H. Prescott, S. Lipka, S. Baldwin, N.F. Sheppard Jr., J.M. Maloney, J. Coppeta, B. Yomtov, M.A. Staples, J.T. Santini Jr., Nat. Biotechnol. 24, 437 (2006) T.J. Smith, P.J. Coyne, W.R. Smith, J.D. Roberts, V. Smith, American Journal Hematology 78, 153 (2005) S. Smith, T.B. Tang, J.G. Terry, J.T.M. Stevenson, B.W. Flynn, H.M. Reekie, A.F. Murray, A.M. Gundlach, D. Renshaw, B. Dhillon, A. Ohtori, Y. Inoue, A.J. Walton, IET Nanobiotechnology 1, 80 (2007) H. Tamagawa, Mater. Lett. 64, 749 (2010) H. Tamagawa, K. Kikuchi, G. Nagai, Sensors Actuators, A: Physical 163, 356 (2010) T.B. Tang, S. Smith, B.W. Flynn, J.T.M. Stevenson, A.M. Gundlach, H.M. Reekie, A.F. Murray, D. Renshaw, B. Dhillon, A. Ohtori, Y. Inoue, J.G. Terry, A.J. Walton, IET Nanobiotechnology 2, 72 (2008) K. Vollmers, D.R. Frutiger, B.E. Kratochvil, B.J. Nelson, Appl. Phys. Lett. 92 (2008) Y. Wang, R. Zhao, S. Wang, Z. Liu, R. Tang, Biomaterials 75, 71 (2016) T. Weigel, R. Mohr, A. Lendlein, Smart Materials Structures 18, 025011 (2009) S.S. Zaidi, F. Lamarque, J. Favergeon, O. Carton, C. Prelle, M. Lejeune, A. Zeinert, Journal Intelligent Material Systems Structures 21, 175 (2010)