Fracture resistance and failure modes of polymer infiltrated ceramic endocrown restorations with variations in margin design and occlusal thickness

Journal of Prosthodontic Research - Tập 62 - Trang 293-297 - 2018
Doaa Taha1,2, Sebastian Spintzyk1, Christine Schille1, Ahmed Sabet2, Marwa Wahsh2, Tarek Salah2, Jürgen Geis-Gerstorfer1
1Section Medical Materials Science & Technology, University Hospital Tübingen, Tübingen, Germany
2Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt

Tài liệu tham khảo

Fennis, 2002, A survey of cusp fractures in a population of general dental practices, Int J Prosthodont, 15, 559 Sagsen, 2006, Effect of bonded restorations on the fracture resistance of root filled teeth, Int Endod J, 39, 900, 10.1111/j.1365-2591.2006.01176.x Jantarat, 2001, An investigation of cuspal deformation and delayed recovery after occlusal loading, J Dent, 29, 363, 10.1016/S0300-5712(01)00018-5 Schwartz, 2004, Post placement and restoration of endodontically treated teeth: a literature review, J Endod, 30, 289, 10.1097/00004770-200405000-00001 Dietschi, 2008, Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, part II (Evaluation of fatigue behavior, interfaces, and in vivo studies), Quintessence Int, 39, 117 Ortega, 2004, Evaluation of fracture resistance of endodontically treated maxillary premolars, restored with ceromer or heat-pressed ceramic inlays and fixed with dual-resin cements, J Oral Rehabil, 31, 393, 10.1046/j.1365-2842.2003.01239.x Bitter, 2007, Post-endodontic restorations with adhesively luted fiber-reinforced composite post systems: a review, Am J Dent, 20, 353 Genovese, 2005, Finite element analysis of a new customized composite post system for endodontically treated teeth, J Biomech, 38, 2375, 10.1016/j.jbiomech.2004.10.009 Bindl, 1999, Clinical evaluation of adhesively placed Cerec endo-crowns after 2 years—preliminary results, J Adhes Dent, 1, 255 Lin, 2011, Evaluation of failure risks in ceramic restorations for endodontically treated premolar with MOD preparation, Dent Mater, 27, 431, 10.1016/j.dental.2010.10.026 Lander, 2008, Endocrowns: a clinical report, Quintessence Int, 39, 99 Magne, 2009, Simulated fatigue resistance of composite resin versus porcelain CAD/CAM overlay restorations on endodontically treated molars, Quintessence Int, 40, 125 Zarone, 2006, Evaluation of the biomechanical behavior of maxillary central incisors restored by means of endocrowns compared to a natural tooth: a 3D static linear finite elements analysis, Dent Mater, 22, 1035, 10.1016/j.dental.2005.11.034 Lin, 2010, Finite element and Weibull analyses to estimate failure risks in the ceramic endocrown and classical crown for endodontically treated maxillary premolar, Eur J Oral Sci, 118, 87, 10.1111/j.1600-0722.2009.00704.x Pippin, 1995, Clinical evaluation of restored maxillary incisors: veneers vs. PFM crowns, J Am Dent Assoc, 126, 1523, 10.14219/jada.archive.1995.0081 Magne, 2009, Thickness of CAD–CAM composite resin overlays influences fatigue resistance of endodontically treated premolars, Dent Mater, 25, 1264, 10.1016/j.dental.2009.05.007 Magne, 2009, Influence of overlay restorative materials and load cusps on the fatigue resistance of endodontically treated molars, Quintessence Int, 40, 729 Tsai, 1998, Influence of glass-ceramic thickness on Hertzian and bulk fracture mechanisms, Int J Prosthodont, 11, 27 Dirxen, 2013, Clinical performance of a new biomimetic double network material, Open Dent J, 7, 118, 10.2174/1874210620130904003 He, 2011, A novel polymer infiltrated ceramic dental material, Dent Mater, 27, 527, 10.1016/j.dental.2011.02.002 Soares, 2008, Influence of restorative technique on the biomechanical behavior of endodontically treated maxillary premolars. Part I: fracture resistance and fracture mode, J Prosthet Dent, 99, 30, 10.1016/S0022-3913(08)60006-2 Potiket, 2004, In vitro fracture strength of teeth restored with different all-ceramic crown systems, J Prosthet Dent, 92, 491, 10.1016/j.prosdent.2004.09.001 Burke, 1996, Fracture resistance of teeth restored with dentin-bonded crowns: the effect of increased tooth preparation, Quintessence Int, 27, 115 AL-Makramani, 2008, Evaluation of load at fracture of Procera AllCeram copings using different luting cements, J Prosthodont, 17, 120, 10.1111/j.1532-849X.2007.00270.x Goodacre, 2001, Tooth preparations for complete crowns: an art form based on scientific principles, J Prosthet Dent, 85, 363, 10.1067/mpr.2001.114685 Skouridou, 2013, Fracture strength of minimally prepared all-ceramic CEREC crowns after simulating 5 years of service, Dent Mater, 29, e70, 10.1016/j.dental.2013.03.019 Fages, 2013, The endocrown: a different type of all-ceramic reconstruction for molars, J Can Dent Assoc, 79, d140 Magne, 1999, Effect of luting composite shrinkage and thermal loads on the stress distribution in porcelain laminate veneers, J Prosthet Dent, 81, 335, 10.1016/S0022-3913(99)70278-7 Prakki, 2007, Effect of resin luting film thickness on fracture resistance of a ceramic cemented to dentin, J Prosthodont, 16, 172, 10.1111/j.1532-849X.2006.00168.x Waltimo, 1993, A novel bite force recorder and maximal isometric bite force values for healthy young adults, Scand J Dent Res, 101, 171 Waltimo, 1995, Maximal bite force and its association with signs and symptoms of craniomandibular disorders in young Finnish non-patients, Acta Odontol Scand, 53, 254, 10.3109/00016359509005982 Leung, 2015, Comparison of mechanical properties of three machinable ceramics with an experimental fluorophlogopite glass ceramic, J Prosthet Dent, 114, 440, 10.1016/j.prosdent.2015.02.024 Helvey, 2014, The expansion of millable materials: new additions to the market increase patient care-options, Inside Dent Technol, 5, 58