Flow system for the automatic screening of the effect of phenolic compounds on the luminol–hydrogen peroxide–peroxidase chemiluminescence system

Luminescence - Tập 26 Số 6 - Trang 571-578 - 2011
André R. T. S. Araújo1, Fernando Maya, M. Lúcia M.F.S. Saraiva, José L. F. C. Lima, Wolfgang Frenzel, Vı́ctor Cerdà
1REQUIMTE, Departamento de Química, Faculdade de Farmácia da Universidade do Porto, Rua Aníbal Cunha, 164, 4099-030 Porto, Portugal.

Tóm tắt

ABSTRACT

In this work, an automated flow‐based procedure for the screening of the effect of the different phenolic compounds on the chemiluminescence (CL) luminol–hydrogen peroxide–horseradish peroxidase (HRP) system is presented. This procedure involves the combination of multisyringe flow injection analysis (MFSIA) and sequential injection analysis (SIA) techniques and exploits the ability of the different subgroups of phenols, such as cholorophenols, nitrophenols, methylphenols and polyphenols, to enhance or inhibit the described CL system. The implementation of this reaction in the SIA–MSFIA system enabled favourable and precise conditions to evaluate the effect of phenolic compounds, as it involves an in‐line reaction between the phenolic derivative, hydrogen peroxide and peroxidase and subsequent oxidized HRP intermediates generation prior to the fast reaction with the chemiluminogenic reagent. Several studies were then performed with the aim of establishing the appropriate flow system configuration and reaction conditions. It was shown that phenol and chlorophenols produce an enhanced CL response and nitrophenols, methylphenols and polyphenols are inhibitors within the range of concentrations studied (1–100 mg/L). Based on these studies, the developed method was applied to the determination of total polyphenol and phenol content in wine/grape seeds and water samples, respectively, and the results obtained showed good agreement with those furnished by the corresponding Folin–Ciocalteu and 4‐aminoantipyrine reference methods. The developed approach is further pursued by designing an automated generic tool for performing studies of peroxidase‐catalysed CL reactions of luminol focused on the detection of compounds that will affect the rate of those reactions. Copyright © 2011 John Wiley & Sons, Ltd.

Từ khóa


Tài liệu tham khảo

10.1002/9783527623259

10.1016/S0165-9936(02)00307-2

10.1016/j.aca.2007.08.030

10.1016/j.talanta.2009.09.033

10.1201/9781482270693

10.1007/s00216-006-0439-9

10.1016/0003-2670(96)00077-3

10.1002/(SICI)1099-1271(199803/04)13:2<75::AID-BIO469>3.0.CO;2-7

10.1016/j.foodchem.2007.12.077

10.1002/bio.1137

10.1016/j.talanta.2008.06.025

10.1080/00032710802463014

10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO;2-9

10.1021/ja9605073

Lundin A, 1987, Bioluminescence and chemiluminescence: new perspectives, 555

10.1002/bio.698

10.1016/j.jlumin.2008.05.013

10.1111/j.1751-1097.2004.tb00390.x

10.1007/s00216-005-0223-2

10.1016/S0003-2670(03)00551-8

Popa CV, 2010, Determination of total antioxidant activity of wines using a flow injection method with chemiluminescence detection, Rev Chim Bucharest, 61, 11

10.1007/s00604-004-0254-y

10.1021/jf050106j

10.1021/jf060324s

10.1016/j.aca.2007.04.028

10.1002/(SICI)1521-4109(199810)10:13<908::AID-ELAN908>3.0.CO;2-L

10.1016/j.aca.2005.02.056

10.1016/j.foodchem.2007.04.056

10.1016/j.talanta.2009.11.063

10.1016/j.talanta.2008.10.034

1990, Recueil des méthodes internationales d'analyse des wins et des mouts, 269

EatonAD ClesceriLS GreenbergAE.American Public Health Association American Water Works Association and Water Pollution Control Federation (APHA–AWWA–WPFC). Standard methods for the examination of water and wastewater 20th edn. Washington DC: APHA–AWWA–WPFC 1998.