First Measurements of the Magnetic Axis of Quadrupole Magnets for the NICA Collider
Tóm tắt
Magnetic cryostat system of the Collider is currently being assembled as part of the NICA megascience project. The structural units of the Collider are 70 quadrupole magnets (46 arched, 12 in straight sections and 12 final focus lenses). To correctly alignment these magnets in the beam orbit of the Collider, the position of the magnetic axis has to be determined with an accuracy of ±0.1mm. Vibration wire techniques provides the required measurement accuracy. A new measuring system intended for operations at ambient temperature has been developed and commissioned. The design of the stand and results of measurements of the magnetic axis position are presented.
Tài liệu tham khảo
T. Parfylo et al., “Vibrating wire system for fiducialization NICA Booster superconducting quadrupole magnets,” in Proceedings of the 27th Russian Particle Accelerator Conference (RUPAC’21), Alushta, Russia, 2021 (JACoW Publ., Geneva, 2021), pp 12–16. http://jacow.org/rupac2021/papers/wepsc17.pdfhttps://doi.org/10.18429/JACoW-RuPAC2021-WEPSC17
H. Khodzhibagiyan et al., “Superconducting magnets for the NICA accelerator complex in Dubna,” IEEE Trans. Appl. Supercond. 3, 1795–1798 (2011).
Z. Wolf, “A vibrating wire system for quadrupole fiducialization,” SLAC TN 10 087 (2010).