Extraction of Chronically Implanted Cardiovascular Electronic Device Leads

Springer Science and Business Media LLC - Tập 16 - Trang 1-9 - 2014
Jeffrey Brinker1
1Johns Hopkins Hospital, Baltimore, USA

Tóm tắt

Cardiovascular implantable electronic devices (CIED) are a remarkable success story. These systems are widely used to prevent symptomatic bradycardia, treat malignant tachyarrhythmia, and to restore a more physiologic contraction to a failing left ventricle. Implantation of a CIED usually involves a lifelong commitment to this therapy, which, unfortunately, is not free from complication requiring removal and/or replacement of all or part of the system. The major obstacle to removal of a CIED is the fibrous attachments that develop between a lead and co-existent leads, veins, and the heart. This process increases over time such that, by one year, removal by traction alone may be problematic and, if aggressive, result in complication. Physicians, surgeons, and engineers have refined techniques of percutaneous lead extraction and developed tools, which have facilitated the process, increased success, and lowered the incidence of complication. Extraction may be performed for a variety of indications some of which are unanimously agreed upon while others remain controversial. Proponents of a broadened application of extraction have proffered the concept of ‘lead management,’ which includes the removal of all leads that are not clinically relevant to the patient. The benefit of this approach would be to limit the risk of future complication, such as venous occlusion or thromboembolism, and to obviate the increase in difficulty of extraction (due to longer implant duration) that might accompany removal should that be required in the future. Intuitively appealing as this approach might be, there is little evidence supporting it, and the extraordinarily large number of patients currently implanted with recalled ICD leads is indicative of the potential impact this practice may have. This review will discuss extraction, its indications, and outcomes.

Tài liệu tham khảo

Mond HG, Procemer A. The 11th world survey of cardiac pacer and implantable cardioverter-defibrillator: calender year 2009-A World Society of Arrhythmia’s project. Pacing Clin Electrophysiol. 2011;34:1013–27. Greenspon AJ, Patel JD, Lau E, Ochoa JA, Frisch DR, Ho RT, et al. 16-Year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States: 1993–2008. J Am Coll Cardiol. 2011;58:1001–6. Robboy SJ, Harthorne JW, Leinbach RC, Sanders CA, Austin WG. Autopsy findings with permanent pervenous pacemakers. Circulation. 1969;39:495–501. Maytin M, Epstein LM, John RM. Lead implant duration does not always predict ease of extraction: extraction sheath may be required at < 1 Year. Pacing Clin Electrophysiol. 2011;34:1615–20. Byrd CL, Schwartz SJ, Hedin NB, et al. Intravascular lead extraction using locking stylets and sheaths. Pacing Clin Electrophysiol. 1990;13(12Pt2):171–5. Byrd CL, Wilkoff BL, Love CJ, et al. Intravascular extraction of problematic or infected permanent pacemaker leads: 1994–1996. U.S. extraction database, MED Institute. Pacing Clin Electrophysiol. 1999;22:1348–57. Wilkoff BL, Byrd CL, Love CJ, et al. Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial. J Am Coll Cardiol. 1999;33:1671–6. Hussein AA, Wilkoff BL, Martin DO, et al. Initial experience with the Evolution mechanical dilator sheath for lead extraction: safety and efficacy. Heart Rhythm. 2010;7:870–3. Scott PA, Chow W, Ellis E, et al. Extraction of pacemaker and implantable cardioverter defibrillator leads: a single-centre study of electrosurgical and laser extraction. Europace. 2009;11:1501–4. Bordachar P, Defaye P, Peyrouse E, et al. Extraction of old pacemaker or cardioverter-defibrillator leads by laser sheath versus femoral approach. Circ Arrhythm Electrophysiol. 2010;3:319–23. Le Dolley Y, Thuny F, Mancini J, et al. Diagnosis of cardiac device-related infective endocarditis after device removal. J Am Coll Cardiol Img. 2010;3:673–81. Hauser RG, Katsiyiannis WT, Gornick CC, et al. Death and cardiovascular injuries due to device-assisted implantable cardioverter-defibrillator and pacemaker lead extraction. Europace. 2010;12:395–401. Wilkoff BL, Love CJ, Byrd CL, et al. Transvenous lead extraction: heart rhythm society expert consensus on facilities, training, indications, and patient management. Heart Rhythm. 2009;6:1085–104. An essential source of de facto guidelines for most things associated with lead extraction and heavily relied upon for this review. Henrikson CA, Zhang K, Brinker JA. A survey of the practice of lead extraction in the United States. Pacing Clin Electrophysiol. 2010;33:721–6. Sohal M, Williams SE, Arujuna A, et al. The current practice and perception of cardiac implantable electronic device transvenous lead extraction in the UK. Europace. 2013;15:865–70. Wazni O, Epstein LM, Carrillo RG, et al. Lead extraction in the contemporary setting: the LExICon Study: an observational retrospective study of consecutive laser lead extractions. J Am Coll Cardiol. 2010;55:579–86. A multi-center registry of consecutive patients undergoing laser assisted lead extraction provides a good snapshot of current practice including indications and outcomes. Henrikson CA, Zhang K, Brinker JA. High mid-term mortality following successful lead extraction for infection. Pacing Clin Electrophysiol. 2011;34:32–6. Maytin M, Jones SO, Epstein LM. Long-term mortality after transvenous lead extraction. Circ Arrhythm Electrophysiol. 2012;5:252–7. Golzio PG, Fanelli AL, Vinci M, et al. Lead vegetations in patients with local and systemic cardiac device infections: prevalence, risk factors, and therapeutic effects. Europace. 2013;15:89–100. Sarrazin JF, Philippon F, Tessier M, et al. Usefulness of fluorine-18 positron emission tomography/computed tomography for identification of cardiovascular implantable electronic device infections. J Am Coll Cardiol. 2012;59:1616–25. Marijon E, De Guillebon M, Bordachar P, et al. Safety of deferring the reimplantation of pacing systems after their removal for infectious complications in selected patients: a 1-year follow-up study. J Cardiovasc Electrophysiol. 2010;21:540–4. Baddour LM, Epstein AE, Erickson CC, et al. Update on cardiovascular implantable electronic device infections and their management. A scientific statement from the American Heart Association. Circulation. 2010;121:458–77. Important resource for the management of patients with CIED infection from diagnosis to device replacement. Lopez JA. Conservative management of infected pacemaker and implantable defibrillator sites with a closed antimicrobial irrigation system. Europace. 2013;15:541–5. Furman S, Curtis AB, Conti JB. Recognition and correction of subcuticular malposition of pacemaker pulse generators. Pacing Clin Electrophysiol. 2001;24:1224–7. Ishii K, Kodani E, Miyamoto S, et al. Pacemaker contact dermatitis: the effect use of a polytetrafluorethylene sheet. Pacing Clin Electrophysiol. 2006;29:1299–302. Syburra T, Schurr U, Rahn M, Graves K, Genoni M. Gold-coated pacemaker implantation after allergic reactions to pacemaker compounds. Europace. 2010;12:749–50. Korkeila P, Mustonen P, Koistinen J, et al. Clinical and laboratory risk factors of thrombotic complications after pacemaker implantation: a prospective study. Europace. 2010;12:817–24. Baranowski B, Wazni O, Chung R, et al. Percutaneous extraction of stented device leads. Heart Rhythm. 2012;9:723–7. Kramer DB, Kennedy KF, Noseworthy PA, et al. Characteristics and outcomes of patients receiving new and replacement implantable cardioverter-defibrillators: results from the NCDR. Circ Cardiovasc Qual Outcomes. 2013;06:488–97. An interesting preliminary look at a large number of patients undergoing ICD procedures including the prevalence and management of pre-existent leads which have failed or have been recalled. Suga C, Hayes DL, Hyberger LK, Lloyd MA. Is there an adverse outcome from abandoned pacing leads? J Interv Card Electrophysiol. 2000;4:493–9. Bode F, Himmel F, Reppel M, et al. Should all dysfunctional high-voltage leads be extracted? Results of a single-center long-term registry. Europace. 2012;14:1764–70. Glikson M, Suleiman M, Luria DM, et al. Do abandoned leads pose risk to implantable cardioverter-defibrillator patients? Heart Rhythm. 2009;6:65–8. Amelot M, Foucault A, Scanu P, et al. Comparison of outcomes in patients with abandoned versus extracted implantable cardioverter-defibrillator leads. Arch Cardiovasc Dis. 2011;11:572–7.