Experimental investigation of thermal properties and moisture buffering performance of composite interior finishing materials under different airflow conditions

Building and Environment - Tập 160 - Trang 106175 - 2019
Chengnan Shi1, Huibo Zhang1, Yingli Xuan2
1Department of Architecture, School of Design, Shanghai Jiao Tong University, Shanghai 200240, China
2Tokyo Polytechnic University, Kanagawa, 2430297, Japan

Tài liệu tham khảo

Zhang, 2012, Assessing the moisture buffering performance of hygroscopic material by using experimental method, Build. Environ., 48, 27, 10.1016/j.buildenv.2011.08.012 Fang, 2009, Microstructure and sorption properties of porous mineral materials [J], Mater. Rev., 475 Song, 2018, Review on building energy performance improvement using phase change materials, Energy Build., 158, 776, 10.1016/j.enbuild.2017.10.066 Nghana, 2016, Phase change material's (PCM) impacts on the energy performance and thermal comfort of buildings in a mild climate, Build. Environ., 99, 221, 10.1016/j.buildenv.2016.01.023 Zhou, 2012, Review on thermal energy storage with phase change materials (PCMs) in building applications, Appl. Energy, 92, 593, 10.1016/j.apenergy.2011.08.025 Zhang, 2017, Practical moisture buffering effect of three hygroscopic materials in real-world conditions, Energy Build., 139, 214, 10.1016/j.enbuild.2017.01.021 Ge, 2014, Influence of moisture load profiles on moisture buffering potential and moisture residuals of three groups of hygroscopic materials, Build. Environ., 81, 162, 10.1016/j.buildenv.2014.06.021 Zhang, 2017, Moisture buffering phenomenon and its impact on building energy consumption, Appl. Therm. Eng., 124, 337, 10.1016/j.applthermaleng.2017.05.173 Zhang, 2017, Moisture buffer effect and its impact on indoor environment, Procedia Eng., 205, 1123, 10.1016/j.proeng.2017.10.417 Medina, 2008, On the heat transfer rate reduction of structural insulated panels (SIPs) outfitted with phase change materials (PCMs), Energy, 33, 667, 10.1016/j.energy.2007.11.003 Soares, 2016, Experimental evaluation of the heat transfer through small PCM-based thermal energy storage units for building applications, Energy Build., 116, 18, 10.1016/j.enbuild.2016.01.003 Wen, 2017, Preparation and properties of fatty acid eutectics/expanded perlite and expanded vermiculite shape-stabilized materials for thermal energy storage in buildings, Energy Build., 139, 197, 10.1016/j.enbuild.2017.01.025 Fraine, 2019, Effect of microencapsulation phase change material and diatomite composite filling on hygrothermal performance of sintered hollow bricks, Build. Environ., 154, 145, 10.1016/j.buildenv.2019.02.036 Kang, 2018, Hygrothermal behavior evaluation of walls improving heat and moisture performance on gypsum boards by adding porous materials, Energy Build., 165, 431, 10.1016/j.enbuild.2017.12.052 Park, 2019, Analysis of walls of functional gypsum board added with porous material and phase change material to improve hygrothermal performance, Energy Build., 183, 803, 10.1016/j.enbuild.2018.11.023 Liuzzi, 2013, Hygrothermal behaviour and relative humidity buffering of unfired and hydrated lime-stabilised clay composites in a Mediterranean climate, Build. Environ., 61, 82, 10.1016/j.buildenv.2012.12.006 Rode, 2003 McGregor, 2014, The moisture buffering capacity of unfired clay masonry, Build. Environ., 82, 599, 10.1016/j.buildenv.2014.09.027 Abadie, 2009, Moisture performance of building materials: from material characterization to building simulation using the Moisture Buffer Value concept, Build. Environ., 44, 388, 10.1016/j.buildenv.2008.03.015 Zhu, 2018, Physical and mechanical properties of gypsum-based composites reinforced with PVA and PP fibers, Constr. Build. Mater., 163, 695, 10.1016/j.conbuildmat.2017.12.168 Huang, 2019, Thermal properties and applications of microencapsulated PCM for thermal energy storage: a review, Appl. Therm. Eng., 147, 841, 10.1016/j.applthermaleng.2018.11.007 Collet, 2014, Experimental highlight of hygrothermal phenomena in hemp concrete wall, Build. Environ., 82, 459, 10.1016/j.buildenv.2014.09.018 Shi, 2018, Analysis of moisture buffering effect of straw-based board in civil defence shelters by field measurements and numerical simulations, Build. Environ., 143, 366, 10.1016/j.buildenv.2018.07.018 Maskell, 2018, Determination of optimal plaster thickness for moisture buffering of indoor air, Build. Environ., 130, 143, 10.1016/j.buildenv.2017.11.045 Li, 2012, An investigation of moisture buffering performance of wood paneling at room level and its buffering effect on a test room, Build. Environ., 47, 205, 10.1016/j.buildenv.2011.07.021 Wang, 2014, Effect of the night ventilation rate on the indoor environment and air-conditioning load while considering wall inner surface moisture transfer, Energy Build., 80, 366, 10.1016/j.enbuild.2014.05.051 Liu, 2017, A porous building approach for modelling flow and heat transfer around and inside an isolated building on night ventilation and thermal mass, Energy, 141, 1914, 10.1016/j.energy.2017.11.137 Holman, 2002, vol. 285, 287 Jakob, 1949, vol. 1, 609 Wang, 2014, Study on preparation and heat transfer enhancement of carbon fiber/paraffin/expanded graphite phase change composites, Mater. Rev., 28, 70 Peng, 2006, Investigation on factors affecting the effect of superplasticizers on building gypsum, China Cement Concr. Prod., 8 Langmuir, 1918, The adsorption of gases on plane surface of glass, mica and platinum, J. Am. Chem. Soc., 40, 1361, 10.1021/ja02242a004 International Standard, ISO 12571-2013, Hygrothermal Performance of Building Materials and Products——Determination of hygroscopic sorption properties. BS EN ISO 12572-2016, 2016 Churchill, 1997, A correlating equation for forced convection from gases and liquids to a circular cylinder in a cross flow, ASME J. Heat Transf., 99, 300