Experimental Study of a Self-Centering Beam–Column Connection with Bottom Flange Friction Device

Journal of Structural Engineering - Tập 135 Số 5 - Trang 479-488 - 2009
Michael Wolski1,2,3, James M. Ricles1,2,3, Richard Sause1,2,3
1Bruce G. Johnston Professor of Structural Engineering, ATLSS Center, Dept. of Civil and Environmental Engineering, Lehigh Univ., Bethlehem, PA 18015.
2Joseph T. Stuart Professor of Structural Engineering and Director, ATLSS Center, Dept. of Civil and Environmental Engineering, Lehigh Univ., Bethlehem, PA 18015.
3Project Engineer, McNamara/Salvia, Inc. Consulting Engineers, 160 Federal St., 5th Fl., Boston MA 02110; formerly, Graduate Research Assistant, Dept. of Civil and Environmental Engineering, Lehigh Univ., Bethlehem, PA 18015.

Tóm tắt

Từ khóa


Tài liệu tham khảo

ASTM. (2000). “Standard test methods for tension testing of metallic materials.” ASTM E-8 West Conshohocken Pa.

10.1002/eqe.579

10.1002/eqe.152

10.1061/(ASCE)0733-9445(2002)128:9(1111)

Federal Emergency Management Agency (FEMA). (2003). “NEHRP recommended provisions for seismic regulations for new buildings and other structures. Part 1—Provisions and Part 2—Commentary.” FEMA 450 Washington D.C.

Galambos, T. V. (1998). Guide to stability design criteria for metal structures, 5th Ed., Wiley, New York.

Garlock M. (2002). “Full-scale testing seismic analysis and design of post-tensioned seismic resistant connections for steel frames.” Ph.D. dissertation Civil and Environmental Engineering Dept. Lehigh Univ. Bethlehem Pa.

10.1016/j.jcsr.2007.10.006

10.1016/j.engstruct.2007.05.026

10.1061/(ASCE)0733-9445(2005)131:3(438)

10.1061/(ASCE)0733-9445(2007)133:3(389)

10.1016/j.jcsr.2008.02.018

10.15554/pcij.07012004.112.133

Petty G. (1999). “Evaluation of a friction component for a post-tensioned steel connection.” MS thesis Civil and Environmental Engineering Dept. Lehigh Univ. Bethlehem Pa.

10.1061/(ASCE)0733-9445(2001)127:2(113)

10.1061/(ASCE)0733-9445(2002)128:7(850)

Roeder C. W. (2000). “State of the art report connection performance.” FEMA bulletin No. 355D Washington D.C.

Rojas P. (2003). “Seismic analysis design and evaluation of post-tensioned friction damped connections for steel moment resisting frames.” Ph.D. dissertation Civil and Environmental Engineering Dept. Lehigh Univ. Bethlehem Pa.

10.1061/(ASCE)0733-9445(2005)131:1(1)

Seo, C. Y. , and Sause, R. (2005). “Ductility demands on self-centering systems under earthquake loading.” ACI Struct. J.ASTJEG0889-3241, 102(2), 275–285.