Evaluation of the tongue for oscillometric measurement of arterial pressure in anesthetized Beagle dogs

Veterinary Anaesthesia and Analgesia - Tập 49 Số 2 - Trang 149-155 - 2022
D. Kim1, Hyunseok Kim1, Donghwi Shin1, Jiyoung Kim1, Inhyung Lee1, Won‐gyun Son1
1Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Seoul National University, Seoul, South Korea

Tóm tắt

Từ khóa


Tài liệu tham khảo

Alpert, 2014, Oscillometric blood pressure: a review for clinicians, J Am Soc Hypertens, 8, 930, 10.1016/j.jash.2014.08.014

2008, Manual, electronic, or automated sphygmomanometers, BJM

Binns, 1995, Doppler ultrasonographic, oscillometric sphygmomanometric, and photoplethysmographic techniques for noninvasive blood pressure measurement in anesthetized cats, J Vet Intern Med, 9, 405, 10.1111/j.1939-1676.1995.tb03301.x

Bland, 2007, Agreement between methods of measurement with multiple observations per individual, J Biopharm Stat, 17, 571, 10.1080/10543400701329422

Bodey, 1994, A comparison of direct and indirect (oscillometric) measurements of arterial blood pressure in anaesthetised dogs, using tail and limb cuffs, Res Vet Sci, 57, 265, 10.1016/0034-5288(94)90116-3

Branson, 1997, Evaluation of an oscillometric blood pressure monitor on anesthetized cats and the effect of cuff placement and fur on accuracy, Vet Surg, 26, 347, 10.1111/j.1532-950X.1997.tb01510.x

Brown, 2007, Guidelines for the identification, evaluation, and management of systemic hypertension in dogs and cats, J Vet Intern Med, 21, 542, 10.1111/j.1939-1676.2007.tb03005.x

Clarke, 2014, 634

Cremer, 2019, Assessment of a commercially available veterinary blood pressure device used on awake and anesthetized dogs, Am J Vet Res, 80, 1067, 10.2460/ajvr.80.12.1067

da Cunha, 2016, Agreement between two oscillometric blood pressure technologies and invasively measured arterial pressure in the dog, Vet Anaesth Analg, 43, 199, 10.1111/vaa.12312

Deflandre, 2008, Clinical evaluation of the Surgivet V60046, a non invasive blood pressure monitor in anaesthetized dogs, Vet Anaesth Analg, 35, 13, 10.1111/j.1467-2995.2007.00346.x

Drynan, 2013, Comparison of invasive versus noninvasive blood pressure measurements before and after hemorrhage in anesthetized greyhounds using the Surgivet V9203, J Vet Emerg Crit Care (San Antonio), 23, 523

Eubanks, 2007, Anatomy and clinical examination of the tongue in the dog, J Vet Dent, 24, 271

Garofalo, 2012, Agreement between direct, oscillometric and Doppler ultrasound blood pressures using three different cuff positions in anesthetized dogs, Vet Anaesth Analg, 39, 324, 10.1111/j.1467-2995.2012.00711.x

Haberman, 2006, Evaluation of oscillometric and Doppler ultrasonic methods of indirect blood pressure estimation in conscious dogs, Can J Vet Res, 70, 211

Hermanson, 2019, 202

McMurphy, 2006, Accuracy of an oscillometric blood pressure monitor during phenylephrine-induced hypertension in dogs, Am J Vet Res, 67, 1541, 10.2460/ajvr.67.9.1541

Pascoe, 2011, Perioperative management of fluid therapy, 405

Ramos, 2016, Comparison of blood pressure measurements of anesthetized dogs obtained noninvasively with a cylindrical blood pressure cuff and an anatomically modified conical blood pressure cuff, Am J Vet Res, 77, 59, 10.2460/ajvr.77.1.59

Sawyer, 2004, Evaluation of a new oscillometric blood pressure monitor in isoflurane-anesthetized dogs, Vet Anaesth Analg, 31, 27, 10.1111/j.1467-2995.2004.00141.x

Sawyer, 1991, Comparison of direct and indirect blood pressure measurement in anesthetized dogs, Lab Anim Sci, 41, 134

Schauvliege, 2016, Patient monitoring and monitoring equipment, 77

Séguin, 2012, Surgical treatment of tongue, lip and cheek tumors, 431

Vachon, 2014, Evaluation of oscillometric and Doppler ultrasonic devices for blood pressure measurements in anesthetized and conscious dogs, Res Vet Sci, 97, 111, 10.1016/j.rvsc.2014.05.003

Wernick, 2010, Evaluation of high-definition and conventional oscillometric blood pressure measurement in anaesthetised dogs using ACVIM guidelines, J Small Anim Pract, 51, 318, 10.1111/j.1748-5827.2010.00938.x