Evaluation of intrafraction prostate motion tracking using the Clarity Autoscan system for safety margin validation

Zeitschrift für Medizinische Physik - Tập 30 - Trang 135-141 - 2020
Anne Richter1, Florian Exner1, Stefan Weick1, Ingulf Lawrenz1, Bülent Polat1, Michael Flentje1, Frederick Mantel1
1Department of Radiation Oncology, University of Würzburg, Würzburg, Germany

Tài liệu tham khảo

Hunt, 2018, Adaptive Radiotherapy Enabled by MRI Guidance, ” Clin Oncol (R Coll Radiol), 30, 711, 10.1016/j.clon.2018.08.001 Fontanarosa, 2015, Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management, ” Phys Med Biol, 60, R77, 10.1088/0031-9155/60/3/R77 O'Shea, 2016, Review of ultrasound image guidance in external beam radiotherapy part II: intra-fraction motion management and novel applications, ” Phys Med Biol, 61, R90, 10.1088/0031-9155/61/8/R90 Varadhan, 2009, Assessing prostate, bladder and rectal doses during image guided radiation therapy--need for plan adaptation?, J Appl Clin Med Phys, 10, 2883, 10.1120/jacmp.v10i3.2883 Raaijmakers, 2007, Integrating a MRI scanner with a 6 MV radiotherapy accelerator: impact of the surface orientation on the entrance and exit dose due to the transverse magnetic field, ” Phys Med Biol, 52, 929, 10.1088/0031-9155/52/4/005 Mutic, 2014, The ViewRay system: magnetic resonance-guided and controlled radiotherapy, ” Semin Radiat Oncol, 24, 196, 10.1016/j.semradonc.2014.02.008 Fallone, 2014, The rotating biplanar linac-magnetic resonance imaging system, ” Semin Radiat Oncol, 24, 200, 10.1016/j.semradonc.2014.02.011 Keall, 2015, The first clinical treatment with kilovoltage intrafraction monitoring (KIM): a real-time image guidance method, Med Phys, 42, 354, 10.1118/1.4904023 Kilby, 2010, “The CyberKnife Robotic Radiosurgery System in 2010, ” Technol Cancer Res Treat, 9, 433, 10.1177/153303461000900502 Richter, 2010, Feasibility study for markerless tracking of lung tumors in stereotactic body radiotherapy, Int J Radiat Oncol Biol Phys, 78, 618, 10.1016/j.ijrobp.2009.11.028 Lachaine, 2013, Intrafractional prostate motion management with the Clarity Autoscan system, Med Phys Int, 1, 72 Baker, 2016, Determining intrafractional prostate motion using four dimensional ultrasound system, ” BMC Cancer, 16, 484, 10.1186/s12885-016-2533-5 Biston, 2019, Comparison of electromagnetic transmitter and ultrasound imaging for intrafraction monitoring of prostate radiotherapy, ” Radiotherapy and Oncology, 136, 1, 10.1016/j.radonc.2019.03.020 Grimwood, 2018, In Vivo Validation of Elekta's Clarity Autoscan for Ultrasound-based Intrafraction Motion Estimation of the Prostate During Radiation Therapy, ” Int J Radiat Oncol Biol Phys, 102, 912, 10.1016/j.ijrobp.2018.04.008 Han, 2018, Evaluation of transperineal ultrasound imaging as a potential solution for target tracking during hypofractionated radiotherapy for prostate cancer, ” Radiat Oncol, 13, 151, 10.1186/s13014-018-1097-8 Richardson, 2017, Intrafraction monitoring of prostate motion during radiotherapy using the Clarity((R)) Autoscan Transperineal Ultrasound (TPUS) system, ” Radiography (Lond), 23, 310, 10.1016/j.radi.2017.07.003 Sihono, 2018, Determination of Intrafraction Prostate Motion During External Beam Radiation Therapy With a Transperineal 4-Dimensional Ultrasound Real-Time Tracking System, ” Int J Radiat Oncol Biol Phys, 101, 136, 10.1016/j.ijrobp.2018.01.040 Baker, 2015, Prostate displacement during transabdominal ultrasound image-guided radiotherapy assessed by real-time four-dimensional transperineal monitoring, ” Acta Oncol, 54, 1508, 10.3109/0284186X.2015.1061208 Li, 2017, Prefraction displacement and intrafraction drift of the prostate due to perineal ultrasound probe pressure, ” Strahlenther Onkol, 193, 459, 10.1007/s00066-017-1105-1 Mantel, 2016, Changes in penile bulb dose when using the Clarity transperineal ultrasound probe: A planning study, ” Pract Radiat Oncol, 6, e337, 10.1016/j.prro.2016.04.001 Richter, 2016, Initial results for patient setup verification using transperineal ultrasound and cone beam CT in external beam radiation therapy of prostate cancer, ” Radiat Oncol, 11, 147, 10.1186/s13014-016-0722-7 Adamson, 2010, Prostate intrafraction motion assessed by simultaneous kV fluoroscopy at MV delivery II: adaptive strategies, ” Int J Radiat Oncol Biol Phys, 78, 1323, 10.1016/j.ijrobp.2009.09.079 Kupelian, 2007, Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy,” Int J Radiat Oncol Biol Phys, 67, 1088 Langen, 2008, Observations on real-time prostate gland motion using electromagnetic tracking, ” Int J Radiat Oncol Biol Phys, 71, 1084, 10.1016/j.ijrobp.2007.11.054 Ballhausen, 2015, Intra-fraction motion of the prostate is a random walk, ” Phys Med Biol, 60, 549, 10.1088/0031-9155/60/2/549 Pang, 2018, Analysis of intra-fraction prostate motion and derivation of duration-dependent margins for radiotherapy using real-time 4D ultrasound, ” Physics and Imaging in Radiation Oncology, 5, 102, 10.1016/j.phro.2018.03.008 Benedek, 2017, The Dosimetric Effect of Prostate Motion in Flattening Filter Free VMAT Treatments Using Extreme Hypofractionation, ” International Journal of Radiation Oncology Biology Physics, 99, E637, 10.1016/j.ijrobp.2017.06.2141 Ballhausen, 2018, Shorter treatment times reduce the impact of intra-fractional motion: A real-time 4DUS study comparing VMAT vs. step-and-shoot IMRT for prostate cancer, ” Strahlenther Onkol, 194, 664, 10.1007/s00066-018-1286-2 Ballhausen, 2019, Dosimetric impact of intrafraction motion on boosts on intraprostatic lesions: a simulation based on actual motion data from real time ultrasound tracking, ” Radiat Oncol, 14, 81, 10.1186/s13014-019-1285-1 Yu, 2017, Intrafractional Tracking Accuracy of a Transperineal Ultrasound Image Guidance System for Prostate Radiotherapy, ” Technol Cancer Res Treat, 16, 1067, 10.1177/1533034617728643 Rios, 2017, Population model of bladder motion and deformation based on dominant eigenmodes and mixed-effects models in prostate cancer radiotherapy, ” Med Image Anal, 38, 133, 10.1016/j.media.2017.03.001 Sohn, 2005, Modelling individual geometric variation based on dominant eigenmodes of organ deformation: implementation and evaluation, ” Phys Med Biol, 50, 5893, 10.1088/0031-9155/50/24/009 Sohn, 2012, Dosimetric treatment course simulation based on a statistical model of deformable organ motion, ” Phys Med Biol, 57, 3693, 10.1088/0031-9155/57/12/3693