Evaluation of force-sensing resistors for gait event detection to trigger electrical stimulation to improve walking in the child with cerebral palsy

B.T. Smith1,2, D.J. Coiro1,2, R. Finson1,2, R.R. Betz1,2, J. McCarthy2
1Shriners Hospitals for Children, Philadelphia, USA
2Shriners Hospitals for Children, Philadelphia, PA, USA

Tóm tắt

Force-sensing resistors (FSRs) were used to detect the transitions between five main phases of gait for the control of electrical stimulation (ES) while walking with seven children with spastic diplegia, cerebral palsy. The FSR positions within each child's insoles were customized based on plantar pressure profiles determined using a pressure-sensitive membrane array (Tekscan Inc., Boston, MA). The FSRs were placed in the insoles so that pressure transitions coincided with an ipsilateral or contralateral gait event. The transitions between the following gait phases were determined: loading response, mid- and terminal stance, and pre- and initial swing. Following several months of walking on a regular basis with FSR-triggered intramuscular ES to the hip and knee extensors, hip abductors, and ankle dorsi and plantar flexors, the accuracy and reliability of the FSRs to detect gait phase transitions were evaluated. Accuracy was evaluated with four of the subjects by synchronizing the output of the FSR detection scheme with a VICON (Oxford Metrics, U.K.) motion analysis system, which was used as the gait event reference. While mean differences between each FSR-detected gait event and that of the standard (VICON) ranged from +35 ms (indicating that the FSR detection scheme recognized the event before it actually happened) to -55 ms (indicating that the FSR scheme recognized the event after it occurred), the difference data was widely distributed, which appeared to be due in part to both intrasubject (step-to-step) and intersubject variability. Terminal stance exhibited the largest mean difference and standard deviation, while initial swing exhibited the smallest deviation and preswing the smallest mean difference. To determine step-to-step reliability, all seven children walked on a level walkway for at least 50 steps. Of 642 steps, there were no detection errors in 94.5% of the steps. Of the steps that contained a detection error, 80% were due to the failure of the FSR signal to reach the programmed threshold level during the transition to loading response. Recovery from an error always occurred one to three steps later.

Từ khóa

#Resistors #Event detection #Electrical stimulation #Legged locomotion #Birth disorders #Phase detection #Hip #Force control #Biomembranes #Knee

Tài liệu tham khảo

chizeck, 1985, a foot pressure sensor for use in lower extremity neuroprosthetic development, RESNA 8th Annu Conf, 379 10.1097/00003086-198808000-00009 10.1097/00003086-198808000-00006 10.1109/86.313148 meadows, 1991, multichannel electrical stimulation system for gait assist and cyclical stimulation, RESNA 14th Annu Conf, 391 finson, 1999, intramuscular functional electrical stimulation (fes) to augment walking children with cerebral palsy, Proc RESNA Conf, 143 10.1111/j.1469-8749.1997.tb07414.x 10.1016/S0003-9993(96)90060-X 10.1109/ELECTR.1991.718294 burns, 1995, the effects of intramuscular electrical stimulation on the temporal gait characteristics of a child with spastic diplegia: a case study, Proc RESNA Conf, 369 10.1109/86.867873 10.1016/S0140-6736(88)91379-7 10.1111/j.1469-8749.1994.tb11909.x 10.1016/0387-7604(96)00006-X 10.1097/00001577-199700930-00003 10.1109/91.649904 carmick, 1993, clinical use of neuromuscular electrical stimulation for children with cerebral palsy, part i: lower extremity, Phys Ther, 73, 505, 10.1093/ptj/73.8.505 riso, 1980, an investigation of the carry over or therapeutic effects of fes in the correction of drop foot in the cerebral palsy child, Proc Int Conf Rehabilitation Engineering, 220 gracanin, 1976, six years experiences with fes method applied to children, Eur Medicophys, 12, 61 perry, 1992, Gait Analysis Normal and Pathological Function 10.1007/BF02448931 gage, 1991, cerebral-palsied gait, Gait Analysis in Cerebral Palsy, 101 10.1097/00001577-199700930-00006 10.1016/S0140-6736(86)90837-8 smith, 1996, a portable 24 channel functional electrical stimulation system for upper and lower extremity applications, Proc RESNA Conf, 276 10.1109/7333.928571 10.1109/7333.918277 10.1002/jor.1100120603 10.1111/j.1469-8749.1998.tb15461.x