Bones adjust their structure to withstand the mechanical demands they experience. It is suggested that flow-derived shear stress may be the most significant and primary mediator of mechanical stimulation. In this study, we designed and fabricated a fluid flow cell culture system that can load shear stress onto cells cultured on 3D scaffolds. We evaluated the effect of different culture techniques, namely, (1) continuous perfusion fluid flow, (2) intermittent perfusion fluid flow, and (3) static condition, on the proliferation of osteoblasts seeded on partially deproteinized bones. The flow rate was set at 1 ml/min for all the cells cultured using flow perfusion and the experiment was conducted for 12 days. Scanning electron microscopy analysis indicated an increase in cell proliferation for scaffolds subjected to fluid shear stress. In addition, the long axes of these cells lengthened along the flowing fluid direction. Continuous perfusion significantly enhanced cell proliferation compared to either intermittent perfusion or static condition. All the results demonstrated that fluid shear stress is able to enhance the proliferation of cells and change the form of cells.
Tài liệu tham khảo
Castellon P., Blatz M.B., Block M.S., Finger I.M., Rogers B., Immediate loading of dental implants in the edentulous mandible, J. Am. Dent. Assoc., 2004, 135, 1543–1549
Esposito M., Grusovin M.G., Achille H., Coulthard P., Worthington H.V., Interventions for replacing missing teeth: different times for loading dental implants, Cochrane Database Syst. Rev., 2009, CD003878
Ibañez J.C., Jalbout Z.N., Immediate Loading of Osseotite Implants: Two-Year Results Clinical Science and Techniques, Implant. Dent., 2002, 11, 128–136
Petropoulos V.C., Balshi T.J., Balshi S.F., Extractions, Implant Placement, and Immediate Loading of Mandibular Implants: A Case Report of a Functional Fixed Prosthesis in 5 Hours, Implant. Dent., 2003, 12, 283–290
You L., Temiyasathit S., Lee P., Padmaja C.H.K., Yao W., Kingery W., et al., Osteocytes as mechanosensors in the inhibition of bone resorption due to mechanical loading, Bone, 2008, 42,172–179
Bancroft G.N., Sikavitsas V.I., van den Dolder J., Fluid flow increases mineralized matrix deposition in 3D perfusion culture of marrow stromal osteoblasts in a dose-dependent manner, Proc. Natl. Acad. Sci. USA, 2002, 99, 12600–12605
Cao L., Ding Y., Effects of estrogen and wall-shear stress on rat osteoblats in vitro, J. Pract. Stomatol., 2003, 19, 475–478
Klein N.J., van der Plas A., Semeins C.M., Sensitivity of osteocytes to biomechanical stress in vitro, FASEB J., 1995, 9, 441–445
Knothe Tate M.L., Niederer P., Knothe U., In vivo tracer transport through the lacunocanalicular system of rat bone in an environment devoid of mechanical loading, Bone, 1998, 22, 107–17
Geng T., Luo F.S., Sun H.Y., Desiging a three-dimensional perfusion bioreactor system for bone tissue enginnering, J. Clin. Rehab. Tissue. Eng. Res., 2007, 11, 3476–3479
Jaasma M.J., Plunkett N.A., Design and validation of a dynamic flow perfusion bioreactor for use with compliant tissue engineering scaffolds, J. Biotechnol., 2008, 133, 490–496
Zhao F., Ma T., Perfusion bioreactor system for human mesenchymal stem cell tissue engineering using recirculation bioreactors, Biomaterials, 2005, 26, 7012–7014
Bjerrea L., Büngera C.E., Kassemb M., Myginda T., Flow perfusion culture of human mesenchymal stem cells on silicate-substituted tricalcium phosphate scaffolds, Biomaterials, 2008, 29, 2616–2627
van den Dolder J., Bancroft G.N., Sikavitasas V.I., Flow perfusion culture of marrow stromal osteoblasts in titanium fiber mesh, J. Biomed. Mater. Res. A., 2003, 64, 235–241
Rieder M.J., Carmona R., Krieger JE., Pritchard K.A. Jr., Greene A.S., Suppression of angiotensin-converting enzyme expression and activity by shear stress, Circ. Res., 1997, 80, 312–319
Sikavitsas V.I., Bancroft G.N., Holtorf H.L., Jansen J.A., Mikos A.G., Mineralized matrix deposition by marrow stromal osteoblasts in 3D perfusion culture increases with increasing fluid shear forces, Proc. Natl. Acad. Sci. USA, 2003, 100,14683–14688
Sikavitsas V.I., Bancroft G.N., Lemoine J.J., Liebschner M.A., Dauner M., Mikos A.G., Flow perfusion enhances the calcified matrix deposition of marrow stromal cells in biodegradable nonwoven fiber mesh scaffolds, Ann. Biomed. Eng., 2005, 33, 63–70
Norvell S.M., Alvarez M., Bidwell J.P., Pavalko F.M., Fluid Shear Stress Induces b-Catenin Signaling in Osteoblasts, Calcif. Tissue. Int., 2004, 75, 396–404
Orr D.E., Burg K.J., Design of a modular bioreactor to incorporate both perfusion flow and hydrostatic compression for tissue engineering applications, Ann. Biomed. Eng., 2008, 36, 1228–1241
Wang S.L., Liu N., Yang S.Y., Culture and identification of SD rat osteoblasts by modified enzymatic digestion in vitro, J. Clin. Rehab. Tissue. Eng. Res., 2008, 12, 2983–2987
Varghese S., Wyzga N., Griffiths A.M., Effects of Serum From Children with Newly Diagnosed Crohn Disease on Primary Cultures of Rat Osteoblasts, J. Pediatr. Gastroenterol. Nutr., 2002, 35, 641–648
Goldstein A.S., Juarez T.M., Helmke C.D., Effect of convection on osteoblastic cell growth and function in biodegradable polymer foam scaffolds, Biomaterials, 2001, 22, 1279–1288
Myers K.A., Rattner J.B., Nigel G., Osteoblast-like cells and fluid flow: Cytoskeleton-dependent shear sensitivity, Biochem. Biophys. Res. Commun., 2007, 364, 214–219
Wu D., Ding Y., Effects of fluid shear stress on the proliferation and cell cycle of rat osteoblasts in vitro, J. Clin. Stomatol., 2007, 23, 197–199