Evaluating and defining the sharpness of intraocular lenses
Tài liệu tham khảo
Schauersberger, 2001, Comparison of the biocompatibility of 2 foldable intraocular lenses with sharp optic edges., J Cataract Refract Surg, 27, 1579, 10.1016/S0886-3350(01)01019-7
Buehl, 2002, Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification., J Cataract Refract Surg, 28, 1105, 10.1016/S0886-3350(02)01371-8
Prosdocimo, 2003, Posterior capsule opacification after phacoemulsification: silicone CeeOn Edge versus acrylate AcrySof intraocular lens., J Cataract Refract Surg, 29, 1551, 10.1016/S0886-3350(02)02051-5
Auffarth, 2003, Quantification of posterior capsule opacification with round and sharp edge intraocular lenses., Ophthalmology, 110, 772, 10.1016/S0161-6420(02)01980-2
Nixon, 2004, In vivo digital imaging of the square-edged barrier effect of a silicone intraocular lens., J Cataract Refract Surg, 30, 2574, 10.1016/j.jcrs.2004.06.049
Kohnen, 1996, Scanning electron microscopic analysis of foldable acrylic and hydrogel intraocular lenses., J Cataract Refract Surg, 22, 1342, 10.1016/S0886-3350(96)80095-2
Mencucci, 2006, Scanning electron microscopic analysis of acrylic intraocular lenses for microincision cataract surgery., J Cataract Refract Surg, 32, 318, 10.1016/j.jcrs.2005.12.131
Tetz, 2005, Evaluating and defining the sharpness of intraocular lenses. Part 1: influence of optic design on the growth of the lens epithelial cells in vitro., J Cataract Refract Surg, 31, 2172, 10.1016/j.jcrs.2005.01.025
Tetz, 1997, Photographic image analysis system of posterior capsule opacification., J Cataract Refract Surg, 23, 1515, 10.1016/S0886-3350(97)80022-3
Brown, 1987, An estimate of the human lens epithelial cell size in vivo., Exp Eye Res, 44, 899, 10.1016/S0014-4835(87)80052-0
Peng, 2000, Surgical prevention of posterior capsule opacification. Part 3. Intraocular lens optic barrier effect as a second line of defense., J Cataract Refract Surg, 26, 198, 10.1016/S0886-3350(99)00352-1
Werner, 2004, Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge., J Cataract Refract Surg, 30, 2403, 10.1016/j.jcrs.2004.02.085
Nishi, 1999, Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule., J Cataract Refract Surg, 25, 521, 10.1016/S0886-3350(99)80049-2
Nishi, 2007, Contact inhibition of migrating lens epithelial cells at the capsular bend created by a sharp-edged intraocular lens after cataract surgery., J Cataract Refract Surg, 33, 1065, 10.1016/j.jcrs.2007.02.022
Bhermi, 2002, Failure of a discontinuous bend to prevent lens epithelial cell migration in vitro., J Cataract Refract Surg, 28, 1256, 10.1016/S0886-3350(02)01209-9
Boyce, 2002, Mathematic modeling of the forces between an intraocular lens and the capsule., J Cataract Refract Surg, 28, 1853, 10.1016/S0886-3350(02)01490-6
Gonvers, 1997, Change in capsulorhexis size after implantation of three types of intraocular lenses., J Cataract Refract Surg, 23, 231, 10.1016/S0886-3350(97)80346-X
Kimura, 1998, Measuring the anterior capsule opening after cataract surgery to assess capsule shrinkage., J Cataract Refract Surg, 24, 1235, 10.1016/S0886-3350(98)80018-7
Joo, 1996, Capsular opening contraction after continuous curvilinear capsulorhexis and intraocular lens implantation., J Cataract Refract Surg, 22, 585, 10.1016/S0886-3350(96)80014-9
Tehrani, 2003, Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation., J Cataract Refract Surg, 29, 2127, 10.1016/S0886-3350(03)00352-3
Hayashi, 2005, Intraocular lens factors that may affect anterior capsule contraction., Ophthalmology, 112, 286, 10.1016/j.ophtha.2004.11.013
Werner, 2000, Anterior capsule opacification; a histopathological study comparing different IOL styles., Ophthalmology, 107, 463, 10.1016/S0161-6420(99)00088-3
Werner, 2001, Anterior capsule opacification: correlation of pathologic findings with clinical sequelae., Ophthalmology, 108, 1675, 10.1016/S0161-6420(01)00674-1
Meacock, 2002, The effect of texturing the intraocular lens edge on postoperative glare symptoms: a randomized, prospective, double-masked study., Arch Ophthalmol, 120, 1294, 10.1001/archopht.120.10.1294