Evaluación hemodinámica no invasiva con cardiografía de impedancia: aplicaciones en falla cardíaca y en hipertensión arterial
Tài liệu tham khảo
Kubicek, 1970, Impedance cardiography as a noninvasive means to monitor cardiac function, J Assoc Adv Med Instrum, 4, 79
Koobi, 1999, Non-invasive cardiac output determination: state of the art, Curr Opin Anaesthesiol, 12, 9, 10.1097/00001503-199902000-00003
Thom, 2005, Transthoracic electrical bioimpedance: a means of filling the void?, Emerg Med Australas, 17, 249, 10.1111/j.1742-6723.2005.00731.x
Napoli, 2010, The use of impedance cardiography in predicting mortality in emergency department patients with severe sepsis and septic shock, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine, 17, 452, 10.1111/j.1553-2712.2010.00705.x
Sathyaprabha, 2008, Noninvasive cardiac output measurement by transthoracic electrical bioimpedence: influence of age and gender, J Clin Monit Comput, 22, 401, 10.1007/s10877-008-9148-6
Noble, 1999, Monitoring patients with left ventricular failure by electrical impedance tomography, Eur J Heart Fail, 1, 379, 10.1016/S1388-9842(99)00054-9
Muller, 2010, Reliability of the measurement of stroke volume using impedance cardiography during acute cold exposure, Aviat Space Environ Med, 81, 120, 10.3357/ASEM.2604.2010
Yung, 2004, Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determination in pulmonary arterial hypertension, Congestive heart failure, 10, 7, 10.1111/j.1527-5299.2004.03406.x
Packer, 2006, Utility of impedance cardiography for the identification of short-term risk of clinical decompensation in stable patients with chronic heart failure, J Am Coll Cardiol, 47, 2245, 10.1016/j.jacc.2005.12.071
Havelka, 2011, Correlation between impedance cardiography and B-type natriuretic Peptide levels in dyspneic patients, J Emerg Med, 40, 146, 10.1016/j.jemermed.2008.01.019
Kieback, 2010, Impedance cardiography versus invasive measurements of stroke volume index in patients with chronic heart failure, Int J Cardiol, 143, 211, 10.1016/j.ijcard.2008.11.201
Kamath, 2009, Am Heart J, 158, 217, 10.1016/j.ahj.2009.06.002
Wang, 2006, Impedance cardiography: more questions than answers, Curr Heart Fail Rep, 3, 107, 10.1007/s11897-006-0009-7
de Waal, 2008, Assessment of stroke volume index with three different bioimpedance algorithms: lack of agreement compared to thermodilution, Intensive Care Med, 34, 735, 10.1007/s00134-007-0938-y
McFetridge-Durdle, 2008, Ambulatory impedance cardiography in hypertension: a validation study, Eur J Cardiovasc Nurs, 7, 204, 10.1016/j.ejcnurse.2007.10.003
Heinroth, 2007, Impedance cardiography: a useful and reliable tool in optimization of cardiac resynchronization devices, Europace, 9, 744, 10.1093/europace/eum086
Kasznicki, 1993, The importance of impedance cardiography in monitoring cardiac function in patients with hematological malignancies, Acta Haematol Pol, 24, 123
Ochoa, 2009, Principios de la evaluación hemodinámica no invasiva con cardiografía de impedancia, Rev Col Cardiol, 16, 91
Bour, 2008, Impedance cardiography: a rapid and cost-effective screening tool for cardiac disease, Eur J Intern Med, 19, 399, 10.1016/j.ejim.2007.07.007
Faes, 1999, Towards a theoretical understanding of stroke volume estimation with impedance cardiography, Ann N Y Acad Sci, 873, 128, 10.1111/j.1749-6632.1999.tb09459.x
Kuang, 2010, Mechanism of the formation for thoracic impedance change, Ann Biomed Eng, 38, 1007, 10.1007/s10439-009-9886-8
Sokolovsky, 2008, Stroke volume estimation in heart failure patients using bioimpedance: a realistic simulation of the forward problem, Physiol Meas, 29, S139, 10.1088/0967-3334/29/6/S12
Bernstein, 2005, Stroke volume equation for impedance cardiography, Med Biol Eng Comput, 43, 443, 10.1007/BF02344724
Paredes, 2006, Impedance cardiography for cardiac output estimation: reliability of wrist-to-ankle electrode configuration, Circ J, 70, 1164, 10.1253/circj.70.1164
Woo, 1991, Comparison of thermodilution and transthoracic electrical bioimpedance cardiac outputs, Heart Lung, 20, 357
Fuller, 2006, Improving the accuracy of impedance cardiac output in the intensive care unit: comparison with thermodilution cardiac output, Congestive Heart Failure, 12, 271, 10.1111/j.1527-5299.2006.05755.x
Cybulski, 1993, A comparison between the automatized impedance cardiography and pulsed-wave Doppler echocardiography methods for measurements of stroke volume (SV) and systolic time intervals (STI), J Physiol Pharmacol, 44, 251
Cybulski, 1988, Computer method for automatic determination of stroke volume using impedance cardiography signals, Acta Physiol Pol, 39, 494
Cybulski, 2004, Stroke volume and systolic time intervals: beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions, Med Biol Eng Comput, 42, 707, 10.1007/BF02347554
Karakitsos, 2009, Prognostic utility of impedance cardiography measurements in elderly hemodialysis patients with coronary artery disease, Am J Nephrol, 29, 426, 10.1159/000174855
Hunt, 2009, Circulation, 119, e391, 10.1161/CIRCULATIONAHA.109.192065
Thom, 2006, Heart disease and stroke statistics-2006 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee, Circulation, 113, e85, 10.1161/CIRCULATIONAHA.105.171600
Abraham, 2006, New approaches to monitoring heart failure before symptoms appear, Rev Cardiovasc Med, 7, S33
Hubbard, 1986, The use of impedance cardiography in heart failure, Int J Cardiol, 12, 71, 10.1016/0167-5273(86)90100-2
Yu, 2005, Intrathoracic impedance monitoring in patients with heart failure: correlation with fluid status and feasibility of early warning preceding hospitalization, Circulation, 112, 841, 10.1161/CIRCULATIONAHA.104.492207
Vollmann, 2007, Clinical utility of intrathoracic impedance monitoring to alert patients with an implanted device of deteriorating chronic heart failure, Eur Heart J, 28, 1835, 10.1093/eurheartj/ehl506
Maines, 2010, Intrathoracic impedance and pulmonary wedge pressure for the detection of heart failure deterioration, Europace, 12, 680, 10.1093/europace/eup419
Perego, 2008, device diagnostics identify patients with increased risk for heart failure hospitalization, J Interv Card Electrophysiol, 23, 235, 10.1007/s10840-008-9303-5
Calabrese, 2010, Monitoring intrathoracic impedance in heart failure patients: implications for inpatient use, Dimens Crit Care Nurs, 29, 203, 10.1097/DCC.0b013e3181e6c4fd
Lo, 2007, Utility of impedance cardiography for dyspneic patients in the ED, Am J Emerg Med, 25, 437, 10.1016/j.ajem.2006.10.009
Springfield, 2004, Utility of impedance cardiography to determine cardiac vs. noncardiac cause of dyspnea in the emergency department, Congestive Heart Failure, 10, 14, 10.1111/j.1527-5299.2004.03409.x
Barcarse, 2004, Combination of B-type natriuretic peptide levels and non-invasive hemodynamic parameters in diagnosing congestive heart failure in the emergency department, Congestive Heart Failure, 10, 171, 10.1111/j.1527-5299.2004.03308.x
Peacock, 2006, Impact of impedance cardiography on diagnosis and therapy of emergent dyspnea: the ED-IMPACT trial, Academic emergency medicine: official journal of the Society for Academic Emergency Medicine, 13, 365, 10.1111/j.1553-2712.2006.tb00310.x
Stevenson, 1999, Tailored therapy to hemodynamic goals for advanced heart failure, Eur J Heart Fail, 1, 251, 10.1016/S1388-9842(99)00015-X
Germino, 2009, The management and treatment of hypertension, Clin Cornerstone, 9, S27, 10.1016/S1098-3597(09)60016-8
Parrott, 2005, Systolic blood pressure does not reliably identify vasoactive status in chronic heart failure, Am J Hypertens, 18, 82S, 10.1016/j.amjhyper.2004.11.024
Ferrario, 2010, Individualizing hypertension treatment with impedance cardiography: a meta-analysis of published trials, Ther Adv Cardiovasc Dis, 4, 5, 10.1177/1753944709348236
Linss, 1990, Noninvasive techniques for evaluation of heart function and hemodynamics in arterial hypertension, An overview. Acta Cardiol, 45, 133
Taler, 2002, Resistant hypertension: comparing hemodynamic management to specialist care, Hypertension, 39, 982, 10.1161/01.HYP.0000016176.16042.2F
Smith, 2006, Value of noninvasive hemodynamics to achieve blood pressure control in hypertensive subjects, Hypertension, 47, 771, 10.1161/01.HYP.0000209642.11448.e0
Sanidas, 2009, Thoracic fluid content and impedance cardiography: a novel and promising noninvasive method for assessing the hemodynamic effects of diuretics in hypertensive patients, Hellenic J Cardiol, 50, 465
