Estimation of grip force using the Grip-ball dynamometer

Medical Engineering & Physics - Tập 35 - Trang 1698-1702 - 2013
Aly Chkeir1, Rana Jaber1, David J. Hewson1, Jacques Duchêne1
1Institut Charles Delaunay, UMR CNRS 6279, Université de Technologie de Troyes, 12 rue Marie Curie, CS 42060, Troyes 10004, France

Tài liệu tham khảo

Mathiowetz, 1984, Reliability and validity of grip and pinch strength evaluations, J Hand Surg Am, 9, 222, 10.1016/S0363-5023(84)80146-X Mathiowetz, 1990, Effects of three trials on grip and pinch strength measurements, J Hand Ther, 3, 195, 10.1016/S0894-1130(12)80377-2 Incel, 2002, Grip strength: effect of hand dominance, Singapore Med J, 43, 234 Cooper, 2010, Objectively measured physical capability levels and mortality: systematic review and meta-analysis, Brit Med J, 341, 4467, 10.1136/bmj.c4467 Norman, 2011, Hand grip strength: outcome predictor and marker of nutritional status, Clin Nutr, 30, 135, 10.1016/j.clnu.2010.09.010 Fried, 2001, Frailty in older adults: evidence for a phenotype, J Gerontol A Biol Sci Med Sci, 56, 146, 10.1093/gerona/56.3.M146 Fess, 1992, Grip strength, 41 Mathiowetz, 1985, Grip and pinch strength: normative data for adults, Arch Phys Med Rehabil, 66, 69 Fike, 1982, Measurement of adult hand strength: a comparison of two instruments, Occup Ther J Res, 2, 43, 10.1177/153944928200200105 Richards, 1996, Grip strength measurement: a critical review of tools, methods, and clinical utility, Crit Rev Phys Rehabil Med, 8, 87, 10.1615/CritRevPhysRehabilMed.v8.i1-2.50 Shmerling, 1990, Measurement of joint inflammation in rheumatoid arthritis with indium-111 chloride, Ann Rheum Dis, 49, 88, 10.1136/ard.49.2.88 Lundeberg, 1988, A comparative study of continuous ultrasound, placebo ultrasound and rest in epicondylalgia, Scand J Rehabil Med, 20, 99 Gellman, 1989, Analysis of pinch and grip strength after carpal tunnel release, J Hand Surg Am, 14, 863, 10.1016/S0363-5023(89)80091-7 Desrosiers, 1995, Comparison of the Jamar dynamometer and the Martin vigorimeter for grip strength measurements in a healthy elderly population, Scand J Rehabil Med, 27, 137, 10.2340/165019779527137143 Hogrel JY, Duchêne J. Device for evaluating and/or reinforcing gripping strength. Patent # FR08/05193; 2008. Hewson, 2010, Domo-Grip: functional evaluation and rehabilitation using grip force, Conf Proc IEEE Eng Med Biol Soc, 1308 Jaber, 2012, Design and validation of the Grip-ball for measurement of hand grip strength, Med Eng Phys, 34, 1356, 10.1016/j.medengphy.2012.07.001 Chkeir, 2012, Reliability and validity of the Grip-Ball dynamometer for grip-strength measurement, Conf Proc IEEE Eng Med Biol Soc, 1996 Wimer, 2009, Development of a new dynamometer for measuring grip strength applied on a cylindrical handle, Med Eng Phys, 31, 695, 10.1016/j.medengphy.2009.01.009 Seo, 2008, Investigation of grip force, normal force, contact area, hand size, and handle size for cylindrical handles, Hum Factors, 50, 734, 10.1518/001872008X354192 Harkonen, 1993, Accuracy of the Jamar dynamometer, J Hand Ther, 6, 259, 10.1016/S0894-1130(12)80326-7