Equivalence between invasive and oscillometric blood pressures at different anatomic locations in healthy normotensive anaesthetised horses

Equine Veterinary Journal - Tập 48 Số 3 - Trang 357-361 - 2016
Caitlin Tearney1, Alonso Guedes2, Robert J. Brosnan2
1Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California Davis, Davis, USA.
2Department of Surgical and Radiological Sciences, University of California, Davis, Davis, USA

Tóm tắt

SummaryReasons for performing studyAccurate blood pressure measurement is essential for effective clinical assessment and appropriate interventions in anaesthetised horses. Information on the accuracy of oscillometry for blood pressure measurement on the appendages of mature horses is limited.ObjectivesTo assess equivalence between invasive and oscillometric blood pressures at different anatomic locations in horses.Study designProspective experimental study using 6 healthy mature horses.MethodsBlood pressure was measured invasively in the right transverse facial artery and noninvasively by oscillometry in nondependent limbs and tail of laterally recumbent sevoflurane‐ or desflurane‐anaesthetised horses. Cuff widths of 5–12 cm were tested on the tail, metatarsus, metacarpus and distal radius/ulna. Equivalence between mean arterial pressure (MAP) oscillometric and MAP invasive was assessed using a linear mixed effects model with a significance level of P≤0.05.ResultsTwenty paired measurements were obtained for each cuff size in each of the locations, totalling 340 measurements. There was only one location (tail) and one cuff width (6 cm; cuff width‐to‐tail circumference ratio of 0.25) that resulted in equivalence between MAP measured with the oscillometric and the invasive methods (P = 0.8). All other locations (metacarpus, radius/ulna, metatarsus) and cuff widths were not equivalent (P≤0.01).ConclusionsA cuff width‐to‐tail circumference ratio of 0.25 is recommended for accurate oscillometric blood pressure measurement in mature, laterally recumbent anaesthetised normotensive horses. Studies with variable haemodynamics are warranted. Oscillometric measurements at other extremities and/or with other cuff sizes cannot be recommended for clinical use.

Từ khóa


Tài liệu tham khảo

Grandy J.L., 1987, Arterial hypotension and the development of postanesthetic myopathy in halothane‐anesthetized horses, Am. J. Vet. Res., 48, 192

10.1111/j.1467-2995.2005.00189.x

10.1111/j.2042-3306.1989.tb05663.x

Rioja E., 2012, Perioperative risk factors for mortality and length of hospitalization in mares with dystocia undergoing general anesthesia: a retrospective study, Can. Vet. J., 53, 502

10.1111/j.1532-950X.1990.tb01216.x

10.1016/B978-1-4160-2326-5.00008-0

Parry B.W., 1982, Correct occlusive bladder width for indirect blood pressure measurement in horses, Am. J. Vet. Res., 43, 50

10.1111/j.2042-3306.1979.tb01340.x

Muir W.W., 1983, Automatic noninvasive sphygmomanometry in horses, J. Am. Vet. Med. Assoc., 182, 1230

Geddes L.A., 1977, Indirect mean blood pressure in the anesthetized pony, Am. J. Vet. Res., 38, 2055

10.1111/j.1939-1676.2005.tb02729.x

10.1111/vaa.12101

10.1111/vaa.12035

10.1111/vaa.12203

10.1111/vaa.12143

10.1046/j.1435-6935.2002.00027.x

10.1161/01.CIR.36.6.980

10.1097/00003246-199810000-00014

10.1111/vaa.12213

10.2460/ajvr.2005.66.606

10.2460/ajvr.2005.66.669

10.1161/01.HYP.21.4.504

10.1111/j.2042-3306.1986.tb03695.x

Aarnes T.K., 2012, Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized camelids, Can. Vet. J., 53, 881

10.1097/00000542-198103000-00010