Environmental temperature variations cause degradations in epinephrine concentration and biological activity

The American Journal of Emergency Medicine - Tập 12 - Trang 319-322 - 1994
Terry A. Grant1, Robert G. Carroll2, William H. Church3, Anthony Henry3, N.Heramba Prasad1, Abdel A. Abdel-Rahman4, E.Jackson Allison1
1Department of Emergency Medicine, East Carolina University, Greenville, NC USA
2Department of Physiology, East Carolina University, Greenville, NC, USA
3Department of Chemistry, East Carolina University, Greenville, NC USA
4Department of Pharmacology, East Carolina University, Greenville, NC USA

Tài liệu tham khảo

Palmer, 1985, Altered states: The influence of temperature on prehospital drugs, J Emerg Med Serv, 10, 29 Valenzuela, 1989, Thermal stability of prehospital medications, Ann Emerg Med, 18, 173, 10.1016/S0196-0644(89)80109-X Cummings, 1968, Deterioration of nitroglycerin tablets, J Pharm Sci, 57, 893, 10.1002/jps.2600570545 Fusari, 1973, Nitroglycerin sublingual tablets: Stability of conventional tablets, J Pharm Sci, 62, 122, 10.1002/jps.2600620125 Rottman, 1988, Chemical stability of sublingual nitroglycerin tablets carried on paramedic vehicles, Am J Emerg Med, 6, 681, 10.1016/0735-6757(88)90141-6 Sullivan, 1987, The effect of ionizing radiation on advanced life support medications, Ann Emerg Med, 16, 662, 10.1016/S0196-0644(87)80066-5 American Society of Hospital Pharmacists, 1990, American Hospital Formulary Service Drug Information Williams, 1982, Ion-pair high performance liquid chromatography of terbutaline and catecholamine with aminophylline in intravenous solutions, J Pharm Sci, 71, 956, 10.1002/jps.2600710832 Waraszkiewicz, 1981, Stability-indicating higher performance liquid chromatographic analysis of lidocaine hydrochloride and lidocaine hydrochloride with epinephrine injectable solutions, J Pharm Sci, 70, 1215, 10.1002/jps.2600701109 Fu, 1977, Quantitative high-pressure liquid chromatographic determination of epinephrine in pharmaceutical formulations, J Pharm Sci, 66, 425, 10.1002/jps.2600660329 Kelly, 1985, Stability of epinephrine in dental anesthetic solutions: Implications for autoclave sterillization and elevated temperature storage, Military Med, 150, 112, 10.1093/milmed/150.2.112 Fry, 1980, Concentrations of vasoconstrictors in local anesthetics change during storage in cartridge heaters, J Dent Res, 59, 1163, 10.1177/00220345800590071201 Fry, 1980, Storage at body temperature alters concentration of vasoconstrictors in local anesthetics, J Dent Res, 59, 1069, 10.1177/00220345800590061301 Church WH, Hu SS, Henry AJ: Effect of heating conditions on epinephrine concentration in 1:10,000 injectable cartridges. Am J Emerg Med (in press)