Ensaio estático de flexão após retirada de haste do fêmur proximal (PFN) – Análise in vitro

Revista Brasileira de Ortopedia - Tập 52 - Trang 52-56 - 2017
Leonardo Morais Paiva1, Sílvio Leite de Macedo Neto1, Diogo Ranier de Macedo Souto1, George Neri Barros Ferreira1, Hélio Ismael da Costa1, Anderson Freitas1
1Hospital Ortopédico e Medicina Especializada (Home), Serviço de Quadril, Brasília, DF, Brasil

Tài liệu tham khảo

Gullberg, 1997, World‐wide projections for hip fracture, Osteoporos Int, 7, 407, 10.1007/PL00004148 Yang, 2016, The analysis of biomechanical properties of proximal femur after implant removal, Appl Bionics Biomech, 2016, 4987831, 10.1155/2016/4987831 Kukla, 2001, Femoral neck fracture after removal of the standard gamma interlocking nail: a cadaveric study to determine factors influencing the biomechanical properties of the proximal femur, J Biomech, 34, 1519, 10.1016/S0021-9290(01)00157-9 Mahaisavariya, 2006, Finite element study of the proximal femur with retained trochanteric gamma nail and after removal of nail, Injury, 37, 778, 10.1016/j.injury.2006.01.019 Kröger, 2002, Bone mineral density after the removal of intramedullary nails: a cross‐sectional and longitudinal study, J Orthop Sci, 7, 325, 10.1007/s007760200055 Eberle, 2011, Should extramedullary fixations for hip fractures be removed after bone union?, Clin Biomech, 26, 410, 10.1016/j.clinbiomech.2010.12.002 Strauss, 2007, Calcium phosphate cement augmentation of the femoral neck defect created after dynamic hip screw removal, J Orthop Trauma, 21, 295, 10.1097/BOT.0b013e3180616ba5 Heini, 2004, Femoroplasty‐augmentation of mechanical properties in the osteoporotic proximal femur: a biomechanical investigation of PMMA reinforcement in cadaver bones, Clin Biomech, 19, 506, 10.1016/j.clinbiomech.2004.01.014 Cristofolini, 1996, Mechanical validation of whole bone composite femur models, J Biomech, 29, 525, 10.1016/0021-9290(95)00084-4 Fliri, 2013, Limited V‐shaped cement augmentation of the proximal femur to prevent secondary hip fractures, J Biomater Appl, 28, 136, 10.1177/0885328212443274 Basafa, 2015, Subject‐specific planning of femoroplasty: an experimental verification study, J Biomech, 48, 59, 10.1016/j.jbiomech.2014.11.002 Beckmann, 2007, Femoroplasty--augmentation of the proximal femur with a composite boné cement--feasibility, biomechanical properties and osteosynthesis potential, Med Eng Phys, 29, 755, 10.1016/j.medengphy.2006.08.006