Enhancing the Intermediate Vision of Monofocal Intraocular Lenses Using a Higher Order Aspheric Optic

Journal of Refractive Surgery - Tập 36 Số 8 - Trang 520-527 - 2020
Aixa Alarcón, Carmen Cánovas, Bram Koopman, Henk A Weeber, Gerd U. Auffarth, Patricia Piers

Tóm tắt

PURPOSE: To describe and evaluate a new monofocal intraocular lens (IOL) designed to improve intermediate vision using a unique refractive technology. METHODS: The new monofocal lens is based on a higher order aspheric optic and is designed to improve intermediate vision. Simulated visual acuity from far to −2.00 diopters (D) was calculated using optical bench data. The effect of corneal higher order aberrations (HOAs) on simulated visual acuity, pupil size, and decentration was assessed using realistic computer eye models. The susceptibility to photic phenomena was evaluated by measuring preclinically the intensity of the light distribution in the retinal plane. The new lens design was compared to a standard aspheric monofocal IOL that shares the same platform, material, and primary spherical aberration as the new design. RESULTS: Simulated defocus curves showed increased simulated visual acuity in the intermediate range compared to a standard aspheric monofocal IOL with comparable distance vision, independently of the pupil size and corneal HOAs. At −1.50 D, the new IOL design provided a gain of approximately 0.1 logMAR, whereas at distance, the difference was less than 0.05 logMAR. The tolerance to decentration was also similar in both designs. Finally, experimental results indicate that the susceptibility to photic phenomena with the new lens design was similar to that of a standard aspheric monofocal IOL. CONCLUSIONS: Preclinical data showed that the new lens design improves intermediate vision while maintaining comparable distance image quality and keeping the same photic phenomena profile as a standard aspheric monofocal IOL. [ J Refract Surg . 2020;36(8):520–527.]

Từ khóa


Tài liệu tham khảo

10.1016/j.jcrs.2004.08.049

10.1016/j.jcrs.2006.10.068

10.1111/aos.12538

10.3928/1081-597X-20040701-01

10.1016/j.jcrs.2006.10.035

10.1016/j.ajo.2007.12.023

10.1038/eye.2012.168

10.1016/j.jcrs.2008.11.038

10.3928/1081-597X-20021101-04

10.1364/AO.46.006595

10.1364/BOE.7.001877

10.1117/1.3475956

Weeber HA, van der Mooren M, Boersma S, Alarcon A, Piers PA. Spurious image methodology: from optical bench to clinical assessment. Invest Ophthalmol Vis Sci. 2017;58:1140.

10.1016/S0886-3350(13)80615-3

Bureau of Labor Statistics. American time use survey—2019 results. 2020; Bureau of Labor Statistics.

10.1016/j.ophtha.2007.01.024

10.1016/j.jcrs.2017.08.012

10.1113/jphysiol.1993.sp019515

10.1364/JOSAA.19.000620

10.1167/17.2.2

10.3928/1081-597X-20070401-10

10.3928/10815 97X-20080301-03

10.1016/j.jcrs.2014.10.017

10.1097/j.jcrs.0000000000000061

10.1016/j.ajo.2017.03.018

10.1111/opo.12236

10.1016/j.ophtha.2016.09.039