Electrophysiological measurements with electrode types of different perimodiolar properties and the same cochlear implant electronics – a retrospective comparison study
Tài liệu tham khảo
O'Connell BP, Hunter JB, Gifford RH, Rivas A, Haynes DS, Noble JH, et al. Electrode location and Audiologic performance after Cochlear implantation: a comparative study between nucleus CI422 and CI512 electrode arrays. Otol Neurotol. 2016;37:1032–5.
Tykocinski M, Cohen LT, Pyman BC, Roland T Jr, Treaba C, Palamara J, et al. Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays. Am J Otol. 2000;21:205–11.
Roland JT Jr. A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique. Laryngoscope. 2005;115:1325–39.
Wackym PA, Firszt JB, Gaggl W, Runge-Samuelson CL, Reeder RM. Raulie JC Electrophysiologic effects of placing cochlear implant electrodes in a perimodiolar position in young children. Laryngoscope. 2004;114:71–6.
Roland PS, Wright CG. Surgical aspects of Cochlear implantation: mechanisms of insertional trauma. Adv Adv Otorhinolaryngol. 2006;64:11–30.
Von Ilberg C, Kiefer J, Tillein J, Pfenningdorff T, Hartmann R, Stürzebecher E, et al. Electric-acoustic stimulation of the auditory system. New technology for severe hearing loss. ORL J Otorhinolaryngol Relat Spec. 1999;61:334–40.
Gantz BJ, Turner C, Gfeller KE, Lowder MW. Preservation of hearing in cochlear implant surgery: advantages of combined electrical and acoustical speech processing. Laryngoscope. 2005;115:796–802.
Skarzynski H, Matusiak M, Lorens A, Furmanek M, Pilka A, Skarzynski PH. Preservation of cochlear structures and hearing when using the nucleus slim straight (CI422) electrode in children. J Laryngol Otol. 2016;130:332–9.
Eshraghi AA. Prevention of cochlear implant electrode damage. Curr Opin Otolaryngol Head Neck Surg. 2006;14:323–8.
Adunka OF, Pillsbury HC, Kiefer J. Combining perimodiolar electrode placement and atraumatic insertion properties in cochlear implantation fact or fantasy? Acta Otolaryngol. 2006;126:475–82.
Fraysse B, Macias AR, Sterkers O, Burdo S, Ramsden R, Deguine O, et al. Residual hearing conservation and electroacoustic stimulation with the nucleus 24 contour advance cochlear implant. Otol Neurotol. 2006;27:624–33.
Huarte RM, Roland JT Jr. Toward hearing preservation in cochlear implant surgery. Curr Opin Otolaryngol Head Neck Surg. 2014;22:349–52.
Van Abel KM, Dunn CC, Sladen DP, Oleson JJ, Beatty CW, Neff BA, et al. Hearing preservation among patients undergoing cochlear implantation. Otol Neurotol. 2015;36:416–21.
Bento RF, Danieli F, Magalhaes AT, Gnansia D, Hoen M. Residual hearing preservation with the EVO® Cochlear implant electrode array: preliminary results. Int Arch Otorhinolaryngol. 2016;20:353–8.
Holden LK, Finley CC, Firszt JB, Holden TA, Brenner C, Potts LG, et al. Factors affecting open-set word recognition in adults with cochlear implants. Ear Hear. 2013;34:342–60.
Aschendorff A, Briggs R, Brademann G, Helbig S, Hornung J, Lenarz T, et al. Clinical investigation of the nucleus slim Modiolar electrode. Audiol Neurootol. 2017;22:169–79.
Cuda D, Murri A. Cochlear implantation with the nucleus slim modiolar electrode (CI532): a preliminary experience. Eur Arch Otorhinolaryngol. 2017;274:4141–8.
Ramos-Macias AR, De Miguel A, Falcon-González JC. Mechanisms of electrode fold-over in cochlear implant surgery when using a flexible and slim perimodiolar electrode array. Acta Otolaryngol. 2017;137:1129–35.
McJunkin JL, Durakovic N, Herzog J, Buchman CA. Early outcomes with a slim, Modiolar Cochlear implant electrode Array. Otol Neurotol. 2018;39:28–33.
Hey M, Wesarg T, Mewes A, Helbig S, Hornung J, Lenarz T, et al. Objective, audiological and quality of life measures with the CI532 slim modiolar electrode. Cochlear Implants Int. 2018;20:80–90.
Perényi Á, Jóri J, Csanády M, Rovó L. Dimensions of the human temporal bone that are relevant to cochlear implantation surgery in infants and toddlers –A clinical-radiological study. [Az emberi halántékcsont csecsemő- és kisgyermekkori cochleáris implantáció szempontjából releváns dimenziói – Klinikoradiológiai vizsgálat] Accepted for publication in Orv Hetil, 2019.
Nagy R, Jarabin JA, Dimák B, Perényi Á, Tóth F, Szűts V, et al. Possibilities for residual hearing preservation with nucleus CI532 slim Modiolar electrode array. Case report. Orv Hetil. 2018;159:1680–8.
Kiss JG, Toth F, Nagy A, Jarabin J, Szamoskozi A, Torkos A, et al. Neural response telemetry in cochlear implant users. Int Tinnitus J. 2003;9:59–60.
Cafarelli Dees D, Dillier N, Lai WK, Von Wallenberg E, van Dijk B, et al. Normative findings of electrically evoked compound action potential measurements using the neural response telemetry of the nucleus CI24M cochlear implant system. Audiol Neurootol. 2005;10:105–16. https://doi.org/10.1159/000083366.
Baysal E, Karatas E, Deniz M, Baglam T, Durucu C, Karatas ZA, et al. Intra- and postoperative electrically evoked stapedius reflex thresholds in children with cochlear implants. Int J Pediatr Otorhinolaryngol. 2012;76:649–52.
Rajati M, Ghassemi MM, Bakhshaee M, Tale MR, Tayarani H. Effect of stylet removal on neural response telemetry and stapedial reflex thresholds during cochlear implantation. Auris Nasus Larynx. 2014;41:255–8.
Müller A, Hocke T, Mir-Salim P. Intraoperative findings on ECAP-measurement: normal or special case? Int J Audiol. 2015;54:257–64.
Boyer E, Karkas A, Attye A, Lefournier V, Escude B, Schmerber S. Scalar localization by cone-beam computed tomography of cochlear implant carriers: a comparative study between straight and periomodiolar precurved electrode arrays. Otol Neurotol. 2015;36:422–9.
Mittmann P, Todt I, Ernst A, Rademacher G, Mutze S, Göricke S, et al. Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study. Eur Arch Otorhinolaryngol. 2016;273:4251–6.