Cảm Biến Miễn Dịch Điện Hóa Kết Hợp Với Nghiên Cứu Mạng Nơ-ron Nhân Tạo Để Phát Hiện Vi Khuẩn Gây Bệnh Sử Dụng Điện Cực Carbon Trong Suốt Đã Được Chỉnh Sửa

Springer Science and Business Media LLC - Tập 59 - Trang 975-985 - 2023
S. Panhwar1,2, H. A. Keerio3,4, A. Ali5, N. H. Khokhar6, M. Muqeet7, G. S. Solangi8
1Department of Civil Engineering, National University of Science, and Technology, Quetta, Pakistan
2Gazi University, Faculty of Pharmacy, Department of Analytical Chemistry, Ankara, Turkey
3Department of Environmental Engineering, Quaid E Awam University of Engineering Science and Technology, Nawabshah, Pakistan
4Faculty of Engineering & Quantity Surveying, INTI International University, Nilai, Malaysia
5Department of Civil Engineering Technology, Benazir Bhutto Shaheed University of Technology & Skill. Development, Khairpur, Pakistan
6Department of Science and Technology, Civil Engineering Technology Program, Indus University, Karachi, Pakistan
7Department of Chemical and Energy Engineering, Pak-Austria Fachhochschule: Institute of Applied Sciences and Technology, Mang, Pakistan
8Department of Civil Engineering, Mehran UET, Khairpur Mirs, Campus, Pakistan

Tóm tắt

Chúng tôi báo cáo kết quả của các nghiên cứu liên quan đến việc chế tạo một cảm biến miễn dịch điện hóa để phát hiện Escherichia coli ATCC 25922 sử dụng AuNPs-GCE-avidin-Ab-E. coli dựa trên hợp chất phức tạp. Trong sự hiện diện của vi khuẩn mục tiêu, kháng thể đặc hiệu được phủ lên bề mặt bằng các hạt nano vàng (AuNPs). Hình thái chi tiết của AuNPs được tổng hợp đã được xác nhận bằng các kỹ thuật phân tích. Cảm biến miễn dịch được đề xuất cho thấy hoạt tính điện xúc tác cao và phản ứng tuyến tính tại giá trị tiềm năng cực đại trên một dải nồng độ rộng của E. coli ATCC 25922 từ 10^1 đến 10^5 CFU/mL. Các kết quả được tương quan với phương trình tuyến tính (R2 = 0.991). Các kết quả ghi nhận có phản ứng trong sự hiện diện của E. coli ATCC 25922 với các dòng vi khuẩn khác như Salmonella typhi, Klebsiella aerogenes, và E. coli O57:H7 chỉ ra tính chọn lọc cao của cảm biến miễn dịch điện hóa. Một phương pháp mạng nơ-ron nhân tạo (ANN) kết hợp hoạt động như một mô hình mạnh mẽ để hiểu và phân tích dữ liệu thông minh của kết quả biến đổi kỹ thuật số. Phương pháp hồi quy được xác định của cảm biến chế tạo được chọn để đánh giá kỹ thuật dựa trên ANN mà được khởi xướng trở thành một phương pháp được biết đến nổi bật. Kỹ thuật đã áp dụng xác nhận tính ứng dụng cao cho vi khuẩn mục tiêu trong các mẫu bị nhiễm của phức hợp sandwich. Do đó, kết quả đạt được đã chứng minh rằng tính năng của việc thu thập và phân tích dữ liệu mô phỏng là rất đáng tin cậy và hấp dẫn. Hơn nữa, cảm biến miễn dịch được chế tạo có thể được sử dụng để sàng lọc nước ô nhiễm và ngăn ngừa dịch bệnh truyền nhiễm nguy hiểm đến tính mạng.

Từ khóa

#cảm biến miễn dịch điện hóa #mạng nơ-ron nhân tạo #Escherichia coli #hạt nano vàng #điện cực carbon trong suốt

Tài liệu tham khảo

Lee, J., Perera, D., Glickman, T., and Taing, L., Prog. Disaster Sci., 2020, vol. 8, p. 100123. https://doi.org/10.1016/j.pdisas.2020.100123 Cissé, G., Acta Trop., 2019, vol. 194, p. 181188. https://doi.org/10.1016/j.actatropica.2019.03.012 Ramanujam, A., Neyhouse, B., Keogh, R.A., Muthuvel, M., Carroll, R.K., and Botte, G.G., Chem. Eng. J., 2021, vol. 411, p. 128453. https://doi.org/10.1016/j.cej.2021.128453 Panhwar, S., Ilhan, H., Hassan, S.S., Zengin, A., Boyacı, I.H., and Tamer, U., Electroanalysis, 2020, vol. 32, pp. 2244–2252. https://doi.org/10.1002/elan.202060185 Barrantes, K., Chacón, L., Morales, E., Rivera-Montero, L., Pino, M., Jiménez, A.G., et al., Water Health, 2022, vol. 20, pp. 344–355. https://doi.org/10.2166/wh.2022.230 Peprah, C., Oduro-Ofori, E., and Asante-Wusu, I., J. Sustain. Dev., 2015, vol. 8, pp. 310–325. https://doi.org/10.5539/jsd.v8n8p310 Pouramin, P., Nagabhatla, N., and Miletto, M., Front. Water, 2020, vol. 2, pp. 1–25. https://doi.org/10.3389/frwa.2020.00006 Panhwar, S., Aftab, A., Keerio, H.A., Sarmadivaleh, M., and Tamer, U. J., Electrochem. Soc., 2021, vol. 168, p. 037514. https://doi.org/10.1149/1945-7111/abec67 Zhang, S., Li, X., Wu, J., Coin, L., O’brien, J., Hai, F., et al., Water, 2021, vol. 13, p. 3551. https://doi.org/10.3390/w13243551 Altenburger, R., Brack, W., Burgess, R.M., Busch, W., Escher, B.I., Focks, A., et al., Environ. Sci. Eur., 2019, vol. 31, pp. 1–17. https://doi.org/10.1186/s12302-019-0193-1 Canciu, A., Tertis, M., Hosu, O., Cernat, A., Cristea, C., and Graur, F., Sustainability, 2021, vol. 13, p. 7229. https://doi.org/10.3390/su13137229 Choi, Y., Lee, S., Lee, H., Lee, S., Kim, S., Lee, J., et al., Korean J. Food Sci. Anim. Resour., 2018, vol. 38, p. 829. https://doi.org/10.5851/kosfa.2018.e19 Bhatt, R.T., Nagwadiya, M.A., Chandran, S., and Yagnik, B.N., J. Appl. Nat. Sci. 2018, vol. 10, pp. 905–909. https://doi.org/10.31018/jans.v10i3.1796 Electroanalytical Applications of Quantum Dot-Based Biosensors, Uslu, B., Ed., Elsevier, 2021, pp. 379–393. https://doi.org/10.1016/B978-0-12-821670-5.00003-8 Panhwar, S., Hassan, S.S., Mahar, R.B., Carlson, K., and Talpur, M.Y., J. Electrochem. Soc., 2019, vol. 166, p. B227. https://doi.org/10.1149/2.0691904jes Iftikhar, T., Aziz, A., Ashraf, G., Xu, Y., Li, G., Zhang, T., et al., Food Chem., 2022, vol. 395, p. 133642. https://doi.org/10.1016/j.foodchem.2022.133642 Liu, X., Li, W.-J., Li, L., Yang, Y., Mao, L.-G., et al., Sens. Actuators B Chem., 2014, vol. 191, pp. 408–414. https://doi.org/10.1016/j.snb.2013.10.033 Petryayeva, E. and Krull, U.J., Anal. Chim. Acta, 2011, vol 706, pp. 8–24. https://doi.org/10.1016/j.aca.2011.08.020 Butler, K.T., Davies, D.W., Cartwright, H., Isayev, O., and Walsh, A., Nature, 2018, vol. 559, pp. 547–555. https://doi.org/10.1038/s41586-018-0337-2 Archana, P., Divyabharathi, P., and Joshya, Y.C., J. Phys. Conf. Ser. 2021, vol. 1979, p. 012016. https://doi.org/10.1088/1742-6596/1979/1/012016 Schackart, K.E. and Yoon, J.Y., Sensors. 2021, vol. 21, p. 5519. https://doi.org/10.3390/s21165519 Haleem, A., Javaid, M., Singh, R.P., Suman, R., and Rab, S., Sens. J., 2021, vol. 2, p. 100100. https://doi.org/10.1016/j.sintl.2021.100100 The Detection of Biomarkers. Elsevier, Eds. S. Ozkan, N. Bakirhan, F. Mollarasouli, 2022, pp. 255–276. https://doi.org/10.1016/B978-0-12-822859-3.00005-5 Hassan, S.S., Panhwar, S., Nafady, A., Al-Enizi, A.M., Sherazi, S.T.H., Kalhoro, M.S., et al., J. Electrochem. Soc., 2017, vol. 164, p. B427. https://doi.org/10.1149/2.0811709jes Panhwar, S., Keerio, H.A., Ali, A., Aftab, A., Chang, M.A., Khokhar, N.H., et al., Adv. Mater. Process Technol., 2022, vol. 8, pp. 4106–4121. https://doi.org/10.1080/2374068X.2022.2036588 Aljabali, A.A., Akkam, Y., Al Zoubi, M.S., Al-Batayneh, K.M., Al-Trad, B., Abo Alrob, O., et al., Nanomaterials, 2018, vol. 8, p. 174. https://doi.org/10.3390/nano8030174 Mourdikoudis, S., Pallares, R.M., and Thanh, N.T., Nanoscale, 2018, vol. 10, pp. 12871–12934. https://doi.org/10.1039/C8NR02278J Ngo, V.K.T., Nguyen, H.P.U., Huynh, T.P., Tran, N.N.P., Lam, Q.V., and Huynh, T.D., Nanosci. Nanotechnol., 2015, vol. 6, p. 035015. https://doi.org/10.1088/2043-6262/6/3/035015 Masdor, N.A., Altintas, Z., and Tothill, I.E., Chemosensors, 2017, vol. 5, p. 16. https://doi.org/10.3390/chemosensors5020016 Fallah, H., Asadishad, T., Parsanasab, G.M., Harun, S.W., Mohammed, W.S., and Yasin, M., Water. Eng. J., 2021, vol. 25, pp. 1–8. https://doi.org/10.4186/ej.2021.25.12.1 Li, F., Zhao, Q., Wang, C., Lu, X., Li, X. F., and Le, X.C., Anal. Chem., 2010, vol. 82, pp. 3399–3403. https://doi.org/10.1021/ac100325f Panhwar, S., Aftab, A., Muqeet, M., Keerio, H.A., Solangi, G.S., Suludere, Z., et al., J. Electron. Mater., 2021, vol. 50, pp. 7119–7125. https://doi.org/10.1007/s11664-021-09247-2 Gutés A., Céspedes F., Alegret S., and Del Valle M., Biosens Bioelectron., 2005, vol. 20, pp. 1668–1673. https://doi.org/10.1016/j.bios.2004.07.026 Abu-Ali, H., Nabok, A., and Smith, T.J., Anal. Bioanal. Chem., 2019, vol. 411, pp. 7659–7668. https://doi.org/10.1007/s00216-019-01853-8 Sheng, Y., Qian, W., Huang, J., Wu, B., Yang, J., Xue, T., et al., Microchim. Acta, 2019, vol. 186, pp. 1–12. https://doi.org/10.1007/s00604-019-3652-x