Effects of pretreatments and hydrothermal aging on biaxial flexural strength of lithium di-silicate and Mg-PSZ ceramics

Journal of Dentistry - Tập 55 - Trang 25-32 - 2016
Maria André1, Wen Kou1, Göran Sjögren1, Anders Sundh2
1Dental Materials Science, Faculty of Medicine, Umeå University, SE-901 87 Umeå, Sweden
2Research and Development, Cad.esthetics AB, SE-931 21 Skellefteå, Sweden

Tài liệu tham khảo

Denry, 1996, Recent advances in ceramics for dentistry, Crit. Rev. Oral Biol. Med., 7, 134, 10.1177/10454411960070020201 Rizkalla, 2004, Mechanical properties of commercial high strength ceramic core materials, Dent. Mater., 20, 207, 10.1016/S0109-5641(03)00093-9 Li, 2014, Ceramic dental biomaterials and CAD/CAM technology: state of the art, J. Prosthodot. Res., 58, 208, 10.1016/j.jpor.2014.07.003 Bindl, 2006, Thin-wall ceramic CAD/CAM crown copings: strength and fracture pattern, J. Oral Rehabil., 33, 520, 10.1111/j.1365-2842.2005.01588.x Sundh, 2006, Fracture resistance of all-ceramic zirconia bridges with differing phase stabilizers and quality of sintering, Dent. Mater., 22, 778, 10.1016/j.dental.2005.11.006 Sundh, 2008, A study of the bending resistance of implant-supported reinforced alumina and machined zirconia abutments and copies, Dent. Mater., 24, 611, 10.1016/j.dental.2007.05.021 Åkesson, 2009, Fracture resistance of all-ceramic crowns placed on a preparation with a slice-formed finishing line, J. Oral Rehabil., 36, 516, 10.1111/j.1365-2842.2009.01962.x Pieger, 2014, Clinical outcomes of lithium disilicate single crowns and partial fixed dental prostheses: a systematic review, J. Prosthet. Dent., 112, 22, 10.1016/j.prosdent.2014.01.005 Ozer, 2014, A retrospective survey on long-term survival of posterior zirconia and porcelain-fused-to-metal crowns in private practice, Quintessence Int., 45, 31 Pozzi, 2015, Monolithic lithium disilicate full-contour crowns bonded on CAD/CAM zirconia complete-arch implant bridges with 3 to 5 years of follow-up, J. Oral Implantol., 41, 450, 10.1563/AAID-JOI-D-13-00133 Håff, 2015, A retrospective evaluation of zirconia-fixed partial dentures in general practices: an up to 13-year study, Dent. Mater., 31, 162, 10.1016/j.dental.2014.11.009 Conrad, 2007, Current ceramic materials and systems with clinical recommendations: a systematic review, J. Prosthet. Dent., 98, 389, 10.1016/S0022-3913(07)60124-3 Aboushelib, 2014, Microtensile bond strength of lithium disilicate ceramics to resin adhesives, J. Adhes. Dent., 16, 547 Denry, 2010, Ceramics for dental applications: a review, Materials, 3, 351, 10.3390/ma3010351 Solá-Ruiz, 2013, Survival rates of a lithium disilicate-based core ceramic for three-unit esthetic fixed partial dentures: a 10-year prospective study, Int. J. Prosthodont., 26, 175, 10.11607/ijp.3045 Piconi, 1999, Zirconia as a ceramic biomaterial a review, Biomaterials, 20, 1, 10.1016/S0142-9612(98)00010-6 Lughi, 2010, Low temperature degradation-aging-of zirconia: a critical review of the relevant aspects in dentistry, Dent. Mater., 26, 807, 10.1016/j.dental.2010.04.006 Basu, 2005, Toughening of yttria-stabilised tetragonal zirconia ceramics, Int. Mater. Rev., 50, 239, 10.1179/174328005X41113 Roy, 2007, Not all zirconia femoral heads degrade in vivo, Clin. Orthop. Relat. Res., 465, 220, 10.1097/BLO.0b013e318158b4d3 Hannink, 1994, Relationship between fracture toughness and phase assemblage in Mg-PSZ, J. Am. Ceram. Soc., 77, 571, 10.1111/j.1151-2916.1994.tb07031.x J.D., Cawley, W.E., Lee, Oxide ceramics, in: R.W., Cahn, P., Haasen, E.J., Kramer (Eds.), Materials Science and Technology, Vol. 11: Structure and Properties of Ceramics (M. Swaim, Ed.), New York: VCH (1994). p 49. Denry, 2008, State of the art of zirconia for dental applications, Dent. Mater., 24, 299, 10.1016/j.dental.2007.05.007 Masaki, 1986, Mechanical properties of Y-TZP after aging at low temperatures, Int. J. High Technol. Ceram., 2, 85, 10.1016/0267-3762(86)90011-1 Roy, 2007, Phase transformation, roughness, and microhardness of artificially aged yttria-and magnesia-stabilized zirconia femoral heads, J. Biomed. Mater. Res. A, 15, 1096, 10.1002/jbm.a.31438 Grant, 2001, Effect of HIPping: stress and surface finish on the environmental degradation of Y-TZP ceramics, J. Mater. Sci. Mater. Med., 12, 557, 10.1023/A:1011284016483 Att, 2007, Fracture resistance of different zirconium dioxide three-unit all-ceramic fixed partial dentures, Acta Odontol. Scand., 65, 14, 10.1080/00016350600856232 Nawafleh, 2016, Lithium disilicate restorations fatigue testing parameters: a systematic review, J. Prosthodont., 25, 116, 10.1111/jopr.12376 International Standard, Dentistry, ceramic materials. In: ISO Standard 6872 (2008). Addison, 2007, Resin strengthening of dental ceramics—the impact of surface texture and silane, J. Dent., 35, 416, 10.1016/j.jdent.2006.11.012 Addison, 2008, Application of analytical stress solutions to bi-axially loadeddental ceramic-dental cement bilayers, Dent. Mater., 24, 1336, 10.1016/j.dental.2008.02.013 Posritong, 2013, The impact of hydrofluoric acid etching followed by unfilled resin on the biaxial strength of a glass-ceramic, Dent. Mater., 29, 281, 10.1016/j.dental.2013.08.210 Advanced technical ceramics-Monolithic ceramics-General and textural properties—Part 4: Determination of surface roughness, 2004. In: SS-EN 623-4 Standard: (2004). Fairhurst, 1992, The effect of glaze on porcelain strength, Dent. Mater., 8, 203, 10.1016/0109-5641(92)90084-P Albakry, 2004, Effect of sandblasting grinding, polishing and glazing on the flexural strength of two pressable all-ceramic dental materials, J. Dent., 32, 91, 10.1016/j.jdent.2003.08.006 Hooshmand, 2008, Effect of surface acid etching on the biaxial flexural strength of two hot-pressed glass ceramics, J. Prosthodont., 17, 415, 10.1111/j.1532-849X.2008.00319.x Lohbauer, 2008, Influence of surface roughness on mechanical strength of resin composite versus glass ceramic materials, Dent. Mater., 24, 250, 10.1016/j.dental.2007.05.006 Zogheib, 2011, Effect of hydrofluoric acid etching duration on the roughness and flexural strength of a lithium disilicate-based glass ceramic, Braz. Dent. J., 22, 45, 10.1590/S0103-64402011000100008 Flury, 2012, Influence of surface roughness on mechanical properties of two computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic materials, Oper. Dent., 37, 617, 10.2341/11-391-L Xiaoping, 2014, Effect of etching time and resin bond on the flexural strength of IPS e.max press glass ceramic, Dent. Mater., 30, 330, 10.1016/j.dental.2014.08.373 Menees, 2014, Influence of particle abrasion or hydrofluoric acid etching on lithium disilicate flexural strength, J. Prosthet. Dent., 112, 1164, 10.1016/j.prosdent.2014.04.021 Fraga, 2015, Hard machining: glaze firing and hydrofluoric acid etching: do these procedures affect the flexural strength of a leucite glass-ceramic?, Dent. Mater., 31, 131, 10.1016/j.dental.2015.04.005 Liu, 2001, Identification of various phases in HRTEM images of MgO-PSZ, J. Electron Microsc., 50, 443, 10.1093/jmicro/50.6.443 Cales, 2000, Zirconia as a sliding material: histologic laboratory, and clinical data, Clin. Orthop. Relat. Res., 379, 94, 10.1097/00003086-200010000-00013 Kosmaç, 1999, The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic, Dent. Mater., 15, 426, 10.1016/S0109-5641(99)00070-6 Zhang, 2004, Effect of sandblasting on the long-term performance of dental ceramics, J. Biomed. Mater. Res. B Appl. Biomater., 15, 381, 10.1002/jbm.b.30097 Zhang, 2006, Damage accumulation and fatigue life of particle-abraded ceramics, Int. J. Prosthodont., 19, 442 Guess, 2010, Damage and reliability of Y-TZP after cementation surface treatment, J. Dent. Res., 89, 592, 10.1177/0022034510363253 Chevalier, 1999, Low temperature aging of Y-TZP ceramics, J. Am. Ceram. Soc., 82, 2150, 10.1111/j.1151-2916.1999.tb02055.x Buso, 2011, Biaxial flexural strength of CAD/CAM ceramics, Minerva Stomatol., 60, 311 Lin, 2012, The effect of core material veneering porcelain, and fabrication technique on the biaxial flexural strength and Weibull analysis of selected dental ceramics, J. Prosthodont., 21, 353, 10.1111/j.1532-849X.2012.00845.x Pollington, 2012, Manufacture: characterisation and properties of novel fluorcanasite glass-ceramics, J. Dent., 40, 1006, 10.1016/j.jdent.2012.08.010 Kang, 2013, Flexural strength and microstructure of two lithium disilicate glass ceramics for CAD/CAM restoration in the dental clinic, Restor. Dent. Endod., 38, 134, 10.5395/rde.2013.38.3.134 Haag, 2011, Firing temperature accuracy of four dental furnaces, Swed. Dent. J., 35, 25 Kvam, 2013, Solubility and strength of zirconia-based dental materials after artificial aging, J. Prosthet. Dent., 110, 281, 10.1016/S0022-3913(13)60377-7