Effects of knee flexion on the femoropopliteal artery: A computational study
Tài liệu tham khảo
Brown, 2009, In vivo quantification of femoralpopliteal compression during isometric thigh contraction: assessment using MR angiography, J Magn Reson Imaging, 29, 1116, 10.1002/jmri.21700
Schlager, 2005, Long-segment SFA stenting—the dark sides: in-stent restenosis, clinical deterioration, and stent fractures, J Endovasc Ther, 12, 676, 10.1583/05-1672.1
Müller-Hülsbeck, 2010, Comparison of second-generation stents for application in the superficial femoral artery: an in vitro evaluation focusing on stent design, J Endovasc Ther, 17, 767, 10.1583/10-3069.1
Jonker, 2008, Dynamic forces in the SFA and popliteal artery during knee flexion, Endovasc Today, 5, 53
Allie, 2004, Nitinol stent fractures in the SFA, Endovasc Today, 3, 22
Ganguly, 2011, In-vivo imaging of femoral artery Nitinol stents for deformation analysis, J Vasc Interv Radiol, 22, 244, 10.1016/j.jvir.2010.10.019
Lederman, 2009, Legs bend: why dynamic angiography is important, Catheter Cardiovasc Interv, 74, 799, 10.1002/ccd.22268
Smouse, 2005, Biomechanical forces in the femoropopliteal arterial segment, Endovasc Today, 4, 60
Cheng, 2010, The effect of aging on deformations of the superficial femoral artery resulting from hip and knee flexion: potential clinical implications, J Vasc Interv Radiol, 21, 195, 10.1016/j.jvir.2009.08.027
Cheng, 2006, In vivo MR angiographic quantification of axial and twisting deformations of the superficial femoral artery resulting from maximum hip and knee flexion, J Vasc Interv Radiol, 17, 979, 10.1097/01.RVI.0000220367.62137.E8
Klein, 2009, Quantitative assessment of the conformational change in the femoropopliteal artery with leg movement, Catheter Cardiovasc Interv, 74, 787, 10.1002/ccd.22124
Rho, 1993, Young's modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements, J Biomech, 26, 111, 10.1016/0021-9290(93)90042-D
Vannah, 1996, Indentor tests and finte elemnt modeling of bulk muscular tissue in vivo, J Rehabil Res Dev, 33, 239
Todd, 1994, Three-dimensional computer model of the human buttocks in vivo, J Rehabil Res Dev, 31, 111
Chow, 1978, Deformations and stresses in soft body tissues of a sitting person, J Biomech Eng, 100, 79, 10.1115/1.3426196
Krouskop, 1987, Computer-aided design of a prosthetic socket for an above-knee amputee, J Rehabil Res Dev, 24, 31
Grujicic, 2009, Seat-cushion and soft-tissue material modeling and a finite element investigation of the seating comfort for passenger-vehicle occupants, Mater Des, 30, 4273, 10.1016/j.matdes.2009.04.028
Bader, 1983, Mechanical characteristics of skin and underlying tissues in vivo, Biomaterials, 4, 305, 10.1016/0142-9612(83)90033-9
Oomens, 2003, Can loaded interface characteristics influence strain distributions in muscle adjacent to bony prominences?, Comput Methods Biomech Biomed Eng, 6, 171, 10.1080/1025584031000121034
Mak, 1992, The biomechanical responses of a skin layer to surface loadings, J Biomech, 25, 809, 10.1016/0021-9290(92)90574-K
Yongping, 1999, Effective elastic properties for lower limb soft tissues from manual indentation experiment, IEEE Trans Rehabil Eng, 7, 257, 10.1109/86.788463
Yongping, 2001, State-of-the-art methods for geometric and biomechanical assessments of residual limbs: a review, J Rehabil Res Dev, 38, 487
Tang, 2010, Finite element analysis of contact pressures between seat cushion and human buttock-thigh tissue, Engineering, 2, 720, 10.4236/eng.2010.29093
Holzapfel, 2005, Determination of layer-specific mechanical properties of human coronary arteries with non atherosclerotic intimal thickening and related constitutive modeling, Am J Physiol-Heart Circ Physiol, 289, H2048, 10.1152/ajpheart.00934.2004
Gastaldi, 2010, Modelling of the provisional side-branch stenting approach for the treatment of atherosclerotic coronary bifurcations: effects of stent positioning, Biomech Model Mechanobiol, 9, 551, 10.1007/s10237-010-0196-8
Fleuren, 2009, Muscle activation patterns of knee flexors and extensors during passive and active movement of the spastic lower limb in chronic stroke patients, J Electromyogr Kinesiol, 19, e301, 10.1016/j.jelekin.2008.04.003
Netter, 2006
Shacham, 2010, Measurements of the static friction coefficient between bone and muscle tissues, J Biomech Eng, 132, 084502, 10.1115/1.4001893
Rebelo, 2009, Study of a Nitinol stent deployed into anatomically accurate artery geometry and subjected to realistic service loading, J Mater Eng Perform, 18, 655, 10.1007/s11665-009-9375-0
Tittelbaugh, 2007, Coupling FEA to CFD to investigate the effects of pulsatile blood flow on the dilatation of artery walls
Choi, 2009, Methods for quantifying three-dimensional deformation of arteries due to pulsatile and nonpulsatile forces: implications for the design of stents and stent grafts, Ann Biomed Eng, 37, 14, 10.1007/s10439-008-9590-0
Rasband, 1997
Malek, 1999, Hemodynamic shear stress and its role in atherosclerosis, J Am Med Assoc, 282, 2035, 10.1001/jama.282.21.2035
Lehoux, 2006, Molecular mechanisms of the vascular responses to haemodynamic forces, J Intern Med, 259, 381, 10.1111/j.1365-2796.2006.01624.x
Levesque, 1985, The elongation and orientation of cultured endothelial cells in response to shear stress, J Biomech Eng, 107, 341, 10.1115/1.3138567
Ziegler, 1998, Influence of oscillatory and unidirectional flow environments on the expression of endothelin and nitric oxide synthase in cultured endothelial cells, Arterioscler Thromb Vasc Biol, 18, 686, 10.1161/01.ATV.18.5.686
Moore, 1994, A device for subjecting vascular endothelial cells to both fluid shear stress and circumferential cyclic stretch, Ann Biomed Eng, 22, 416, 10.1007/BF02368248
Barron, 2007, The effect of physiological cyclic stretch on the cell morphology, cell orientation and protein expression of endothelial cells, J Mater Sci Mater Med, 18, 1973, 10.1007/s10856-007-3125-3
Wang, 1995, Cell orientation response to cyclically deformed substrates: experimental validation of a cell model, J Biomech, 28, 1543, 10.1016/0021-9290(95)00101-8
Neidlinger-Wilke, 2001, Cell alignment is induced by cyclic changes in cell length: studies of cells grown in cyclically stretched substrates, J Orthop Res, 19, 286, 10.1016/S0736-0266(00)00029-2
Wang, 2001, Specificity of endothelial cell reorientation in response to cyclic mechanical stretching, J Biomech, 34, 1563, 10.1016/S0021-9290(01)00150-6
Moretti, 2004, Endothelial cell alignment on cyclically-stretched silicone surfaces, J Mater Sci Mater Med, 15, 1159, 10.1023/B:JMSM.0000046400.18607.72
Dartsch, 1989, Response of cultured endothelial cells to mechanical stimulation, Basic Res Cardiol, 84, 268, 10.1007/BF01907974
Duerig, 2002, A comparison of balloon-and self-expanding stents, Min Invas Ther Allied Technol, 11, 173, 10.1080/136457002760273386
