Effect of insert material on forces on quadriceps, collateral ligament, and patellar tendon after rotating platform mobile-bearing total knee arthroplasty

Asian Journal of Surgery - Tập 43 - Trang 742-749 - 2020
Yong-Gon Koh1, Jin-Ah Lee2, Heoung-Jae Chun2, Changhyun Baek3, Kyoung-Tak Kang2
1Joint Reconstruction Center, Department of Orthopaedic Surgery, Yonsei Sarang Hospital, 10 Hyoryeong-ro, Seocho-gu, Seoul 06698, Republic of Korea
2Department of Mechanical Engineering, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, Republic of Korea
3Department of Mechanical and Control Engineering, The Cyber University of Korea, 106 Bukchon-ro, Jongnogu, Seoul, 03051, Republic of Korea

Tài liệu tham khảo

Robertsson, 2001, Patient satisfaction compared with general health and disease-specific questionnaires in knee arthroplasty patients, J Arthroplast, 16, 476, 10.1054/arth.2001.22395a Padua, 2007, Range of motion correlates with patient perception of TKA outcome, Clin Orthop Relat Res, 460, 174, 10.1097/BLO.0b013e318046ccb7 Argenson, 1992, Polyethylene wear in meniscal knee replacement. A one to nine-year retrieval analysis of the Oxford knee, J Bone Joint Surg Br, 74, 228, 10.1302/0301-620X.74B2.1544958 Buechel, 1989, New Jersey low contact stress knee replacement system. Ten-year evaluation of meniscal bearings, Orthop Clin N Am, 20, 147 Matsuda, 1998, Contact stress analysis in meniscal bearing total knee arthroplasty, J Arthroplast, 13, 699, 10.1016/S0883-5403(98)80016-8 Matsuda, 1999, Knee stability in meniscal bearing total knee arthroplasty, J Arthroplast, 14, 82, 10.1016/S0883-5403(99)90207-3 Watanabe, 2005, Comparison between mobile-bearing and fixed-bearing knees in bilateral total knee replacements, Int Orthop, 29, 179, 10.1007/s00264-005-0646-6 Bhan, 2005, A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years, J Bone Joint Surg Am, 87, 2290 Oh, 2009, Meta-analysis comparing outcomes of fixed-bearing and mobile-bearing prostheses in total knee arthroplasty, J Arthroplast, 24, 873, 10.1016/j.arth.2008.06.002 Rimnac, 2008, How do material properties influence wear and fracture mechanisms?, J Am Acad Orthop Surg, 16, S94, 10.5435/00124635-200800001-00019 Edidin, 1999, Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement. Ultra-high-molecular-weight polyethylene, J Arthroplast, 14, 616, 10.1016/S0883-5403(99)90086-4 Pruitt, 2013, Clinical trade-offs in cross-linked ultrahigh-molecular-weight polyethylene used in total joint arthroplasty, J Biomed Mater Res B Appl Biomater, 101, 476 Atwood, 2011, Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene, J Mech Behav Biomed Mater, 4, 1033, 10.1016/j.jmbbm.2011.03.012 Scholes, 2009, Pitch-based carbon-fibre-reinforced poly (ether-ether-ketone) OPTIMA assessed as a bearing material in a mobile bearing unicondylar knee joint, Proc Inst Mech Eng H, 223, 13, 10.1243/09544119JEIM471 Scholes, 2009, Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials, J Mater Sci Mater Med, 20, 163, 10.1007/s10856-008-3558-3 Howling, 2003, Biological response to wear debris generated in carbon based composites as potential bearing surfaces for artificial hip joints, J Biomed Mater Res B Appl Biomater, 67, 758, 10.1002/jbm.b.10068 Kurtz, 2007, PEEK biomaterials in trauma, orthopedic, and spinal implants, Biomaterials, 28, 4845, 10.1016/j.biomaterials.2007.07.013 East, 2015, Wear of PEEK-OPTIMA(R) and PEEK-OPTIMA(R)-Wear Performance articulating against highly cross-linked polyethylene, Proc Inst Mech Eng H, 229, 187, 10.1177/0954411915576353 Scholes, 2010, The wear performance of PEEK-OPTIMA based self-mating couples, Wear, 268, 380, 10.1016/j.wear.2009.08.023 Brockett, 2015 Kim, 2015, Graft extrusion related to the position of allograft in lateral meniscal allograft transplantation: biomechanical comparison between parapatellar and transpatellar approaches using finite element analysis, Arthroscopy, 31, 2380, 10.1016/j.arthro.2015.06.030 Kang, 2017, Validation of a computational knee joint model using an alignment method for the knee laxity test and computed tomography, Bio Med Mater Eng, 28, 417, 10.3233/BME-171686 Koh, 2017, Preservation of kinematics with posterior cruciate-, bicruciate- and patient-specific bicruciate-retaining prostheses in total knee arthroplasty by using computational simulation with normal knee model, Bone Jt Res, 6, 557, 10.1302/2046-3758.69.BJR-2016-0250.R1 Pena, 2006, Why lateral meniscectomy is more dangerous than medial meniscectomy. A finite element study, J Orthop Res : Off Publ Orthop Res Soc, 24, 1001, 10.1002/jor.20037 Haut Donahue, 2003, How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint, J Biomech, 36, 19, 10.1016/S0021-9290(02)00305-6 Pena, 2006, Why lateral meniscectomy is more dangerous than medial meniscectomy. A finite element study, J Orthop Res, 24, 1001, 10.1002/jor.20037 Takeda, 1994, Biomechanical function of the human anterior cruciate ligament, Arthroscopy, 10, 140, 10.1016/S0749-8063(05)80081-7 Blankevoort, 1996, Validation of a three-dimensional model of the knee, J Biomech, 29, 955, 10.1016/0021-9290(95)00149-2 Knight, 2007, Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading, J Biomech, 40, 1550, 10.1016/j.jbiomech.2006.07.027 Greco, 2011, Effect of reinforcement morphology on high-speed sliding friction and wear of PEEK polymers, Wear, 271, 2222, 10.1016/j.wear.2011.01.065 Godest, 2002, Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis, J Biomech, 35, 267, 10.1016/S0021-9290(01)00179-8 Innocenti, 2009, Can medio-lateral baseplate position and load sharing induce asymptomatic local bone resorption of the proximal tibia? A finite element study, J Orthop Surg Res, 4, 26, 10.1186/1749-799X-4-26 Innocenti, 2016, Deviations from optimal alignment in TKA: is there a biomechanical difference between femoral or tibial component alignment?, J Arthroplast, 31, 295, 10.1016/j.arth.2015.07.038 Pegg, 2013, Evaluation of factors affecting tibial bone strain after unicompartmental knee replacement, J Orthop Res, 31, 821, 10.1002/jor.22283 Inoue, 2016, The valgus inclination of the tibial component increases the risk of medial tibial condylar fractures in unicompartmental knee arthroplasty, J Arthroplast, 31, 2025, 10.1016/j.arth.2016.02.043 Vaninbroukx, 2009, Cementing the femoral component in total knee arthroplasty: which technique is the best?, The Knee, 16, 265, 10.1016/j.knee.2008.11.015 Vanlommel, 2011, Cementing the tibial component in total knee arthroplasty: which technique is the best?, J Arthroplast, 26, 492, 10.1016/j.arth.2010.01.107 Chang, 2011, Biomechanical evaluation of proximal tibial behavior following unicondylar knee arthroplasty: modified resected surface with corresponding surgical technique, Med Eng Phys, 33, 1175, 10.1016/j.medengphy.2011.05.007 Ishii, 2007, Effect of knee laxity on in vivo kinematics of meniscal-bearing knee prostheses, The Knee, 14, 269, 10.1016/j.knee.2007.04.002 Kang, 2016, Measuring the effect of femoral malrotation on knee joint biomechanics for total knee arthroplasty using computational simulation, Bone Jt Res, 5, 552, 10.1302/2046-3758.511.BJR-2016-0107.R1 Kutzner, 2010, Loading of the knee joint during activities of daily living measured in vivo in five subjects, J Biomech, 43, 2164, 10.1016/j.jbiomech.2010.03.046 Halloran, 2010, Verification of predicted knee replacement kinematics during simulated gait in the Kansas knee simulator, J Biomech Eng, 132, 081010, 10.1115/1.4001678 Kang, 2017, The effects of posterior cruciate ligament deficiency on posterolateral corner structures under gait- and squat-loading conditions: a computational knee model, Bone Jt Res, 6, 31, 10.1302/2046-3758.61.BJR-2016-0184.R1 Hasegawa, 2006, Dislocation of posterior-stabilized mobile-bearing knee prosthesis. A case report, The Knee, 13, 478, 10.1016/j.knee.2006.07.002 Gioe, 2007, Knee arthroplasty in the young patient: survival in a community registry, Clin Orthop Relat Res, 464, 83, 10.1097/BLO.0b013e31812f79a9 Berry, 2002, Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components, J Bone Joint Surg Am, 84, 171, 10.2106/00004623-200202000-00002 Gioe, 2004, Why are total knee replacements revised?: analysis of early revision in a community knee implant registry, Clin Orthop Relat Res, 100, 10.1097/01.blo.0000147136.98303.9d Barbour, 1997, The influence of stress conditions on the wear of UHMWPE for total joint replacements, J Mater Sci Mater Med, 8, 603, 10.1023/A:1018515318630 Galvin, 2009, Effect of conformity and contact stress on wear in fixed-bearing total knee prostheses, J Biomech, 42, 1898, 10.1016/j.jbiomech.2009.05.010 Willie, 2008, Surface damage analysis of retrieved highly crosslinked polyethylene tibial components after short-term implantation, J Biomed Mater Res B Appl Biomater, 85, 114, 10.1002/jbm.b.30923 Brockett, 2012, Wear of ceramic-on-carbon fiber-reinforced poly-ether ether ketone hip replacements, J Biomed Mater Res B Appl Biomater, 100, 1459, 10.1002/jbm.b.32664 Flanagan, 2010, In vitro friction and lubrication of large bearing hip prostheses, Proc Inst Mech Eng H, 224, 853, 10.1243/09544119JEIM733 Grupp, 2010, Biotribology of alternative bearing materials for unicompartmental knee arthroplasty, Acta Biomater, 6, 3601, 10.1016/j.actbio.2010.04.003 Brockett, 2017, PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: an experimental wear study, Wear, 374–375, 86, 10.1016/j.wear.2016.12.010 Thompson, 2011, Biomechanical effects of total knee arthroplasty component malrotation: a computational simulation, J Orthop Res, 29, 969, 10.1002/jor.21344 Hurley, 1998, Improvements in quadriceps sensorimotor function and disability of patients with knee osteoarthritis following a clinically practicable exercise regime, Br J Rheumatol, 37, 1181, 10.1093/rheumatology/37.11.1181 Mizner, 2005, Early quadriceps strength loss after total knee arthroplasty. The contributions of muscle atrophy and failure of voluntary muscle activation, J Bone Joint Surg Am, 87, 1047, 10.2106/JBJS.D.01992 Fukagawa, 2010, Posterior displacement of the tibia increases in deep flexion of the knee, Clin Orthop Relat Res, 468, 1107, 10.1007/s11999-009-1118-x Kang, 2018, Influence of increased posterior tibial slope in total knee arthroplasty on knee joint biomechanics: a computational simulation study, J Arthroplast, 33, 572, 10.1016/j.arth.2017.09.025