Effect of gap balancing and measured resection techniques on implant migration and contact kinematics of a cementless total knee arthroplasty

The Knee - Tập 31 - Trang 86-96 - 2021
Harley A. Williams1, Jordan S. Broberg1,2, James L. Howard3, Brent A. Lanting3, Matthew G. Teeter1,2,3,4
1Robarts Research Institute, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
2Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
3Department of Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada
4Lawson Health Research Institute, London, Ontario, Canada

Tài liệu tham khảo

Kurtz, 2014, Impact of the economic downturn on total joint replacement demand in the United States: updated projections to 2021, J Bone Joint Surg Am, 96, 624, 10.2106/JBJS.M.00285 Mercuri, 2019, Gap balancing, measured resection, and kinematic alignment: how, when, and why?, JBJS Rev, 7, 10.2106/JBJS.RVW.18.00026 Roussot, 2020, Clinical outcomes of kinematic alignment versus mechanical alignment in total knee arthroplasty: a systematic review, EFORT Open Rev, 5, 486, 10.1302/2058-5241.5.190093 Oussedik, 2020, Alignment in total knee arthroplasty, Bone Joint J, 10.1302/0301-620X.102B3.BJJ-2019-1729 Dennis, 2010, Gap balancing versus measured resection technique for total knee arthroplasty, Clin Orthop Relat Res, 468, 102, 10.1007/s11999-009-1112-3 Daines, 2014, Gap balancing vs. measured resection technique in total knee arthroplasty, Clin Orthop Surg, 6, 1, 10.4055/cios.2014.6.1.1 Stephens, 2014, Clinical alignment variations in total knee arthroplasty with different navigation methods, Knee, 21, 971, 10.1016/j.knee.2014.03.001 Babazadeh, 2014, Gap balancing sacrifices joint-line maintenance to improve gap symmetry: a randomized controlled trial comparing gap balancing and measured resection, J Arthroplasty, 29, 950, 10.1016/j.arth.2013.09.036 Huang, 2017, Meta-analysis of gap balancing versus measured resection techniques in total knee arthroplasty, Bone Joint J, 10.1302/0301-620X.99B2.BJJ-2016-0042.R2 Moon, 2016, Comparison of soft tissue balancing, femoral component rotation, and joint line change between the gap balancing and measured resection techniques in primary total knee arthroplasty: A meta-analysis, Medicine (Baltimore), 95, 10.1097/MD.0000000000005006 Hanada, 2007, Bone landmarks are more reliable than tensioned gaps in TKA component alignment, Clin Orthop Relat Res, 462, 137, 10.1097/BLO.0b013e3180dc92e7 Chao, 2017, Averaging rotational landmarks during total knee arthroplasty reduces component malrotation caused by femoral asymmetry, J Orthop Surg Res, 12, 74, 10.1186/s13018-017-0575-2 Cherian, 2014, Cementless total knee arthroplasty: a review, J Knee Surg, 27, 193, 10.1055/s-0034-1374811 Hofmann, 2002, Cementless total knee arthroplasty in patients 50 years or younger, Clin Orthop Relat Res, 404, 102, 10.1097/00003086-200211000-00018 Miller, 2018, Results of cemented vs cementless primary total knee arthroplasty using the same implant design, J Arthroplasty, 33, 1089, 10.1016/j.arth.2017.11.048 Nam, 2019, Cemented versus cementless total knee arthroplasty of the same modern design: a prospective, randomized trial, J Bone Joint Surg Am, 101, 1185, 10.2106/JBJS.18.01162 Sinicrope, 2019, Increased survivorship of cementless versus cemented TKA in the morbidly obese. A minimum 5-year follow-up, J Arthroplasty, 34, 309, 10.1016/j.arth.2018.10.016 Miller, 2014, Loss of cement-bone interlock in retrieved tibial components from total knee arthroplasties, Clin Orthop Relat Res, 472, 304, 10.1007/s11999-013-3248-4 Laende, 2019, Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties, Bone Joint J, 10.1302/0301-620X.101B7.BJJ-2018-1493.R1 Dennis, 2001, Femoral condylar lift-off in vivo in total knee arthroplasty, J Bone Joint Surg Br, 83, 33, 10.1302/0301-620X.83B1.0830033 Teeter, 2018, Contact kinematics correlates to tibial component migration following single radius posterior stabilized knee replacement, J Arthroplasty, 33, 740, 10.1016/j.arth.2017.09.064 Pijls, 2018, RSA migration of total knee replacements, Acta Orthop, 89, 320, 10.1080/17453674.2018.1443635 Dunbar, 2017, Stable migration of peri-apatite-coated uncemented tibial components in a multicentre study, Bone Joint J, 10.1302/0301-620X.99B12.BJJ-2016-1118.R2 Cook, 2018, Surgeons' and methodologists' perceptions of utilising an expertise-based randomised controlled trial design: a qualitative study, Trials, 19, 478, 10.1186/s13063-018-2832-z Øhrn, 2018, A 2-year RSA study of the Vanguard CR total knee system: A randomized controlled trial comparing patient-specific positioning guides with conventional technique, Acta Orthop, 89, 418, 10.1080/17453674.2018.1470866 Morcos, 2019, Effect of medial soft tissue releases during posterior-stabilized total knee arthroplasty on contact kinematics and patient-reported outcomes, J Arthroplasty, 34, 1110, 10.1016/j.arth.2019.02.026 Teeter, 2017, Contact kinematic differences between gap balanced vs measured resection techniques for single radius posterior-stabilized total knee arthroplasty, J Arthroplasty, 32, 1834, 10.1016/j.arth.2016.12.054 Teeter, 2019, Radiostereometric analysis permits in vivo measurement of very small levels of wear in TKA, Clin Orthop Relat Res, 477, 80, 10.1097/CORR.0000000000000399 Van de Kleut ML, Nair C, Milner JS, Holdsworth DW, Athwal GS, Teeter MG. Invivo reverse total shoulder arthroplasty contact mechanics. J Shoulder Elbow Surg 2020. Prins, 2014, Detecting condylar contact loss using single-plane fluoroscopy: a comparison with in vivo force data and in vitro bi-plane data, J Biomech, 47, 1682, 10.1016/j.jbiomech.2014.02.031 Sharma, 2017, In vivo three-dimensional patellar mechanics: normal knees compared with domed and anatomic patellar components, J Bone Joint Surg Am, 99, 10.2106/JBJS.15.01095 Sporer, 2019, Evaluation of a 3D-printed total knee arthroplasty using radiostereometric analysis: assessment of highly porous biological fixation of the tibial baseplate and metal-backed patellar component, Bone Joint J, 10.1302/0301-620X.101B7.BJJ-2018-1466.R1 Ryd, 1995, Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses, J Bone Joint Surg Br, 77, 377, 10.1302/0301-620X.77B3.7744919 Laende, 2019, Equivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee arthroplasties, Acta Orthop, 90, 172, 10.1080/17453674.2018.1562633 Teeter, 2018, The effects of resection technique on implant migration in single radius posterior-stabilized total knee replacement, J Knee Surg Gao, 2009, Cemented versus uncemented fixation of the femoral component of the NexGen CR total knee replacement in patients younger than 60 years: a prospective randomised controlled RSA study, Knee, 16, 200, 10.1016/j.knee.2008.11.009 Broberg, 2019, Comparison of contact kinematics in posterior-stabilized and cruciate-retaining total knee arthroplasty at long-term follow-up, J Arthroplasty Angerame, 2019, Total knee arthroplasty kinematics, J Arthroplasty, 34, 2502, 10.1016/j.arth.2019.05.037 Dennis, 2003, Multicenter determination of in vivo kinematics after total knee arthroplasty, Clin Orthop Relat Res, 416, 37, 10.1097/01.blo.0000092986.12414.b5 Saevarsson, 2013, Are static and dynamic kinematics comparable after total knee arthroplasty?, J Biomech, 46, 1169, 10.1016/j.jbiomech.2013.01.002 Mu, 2011, Comparison of static and dynamic knee kinematics during squatting, Clin Biomech (Bristol, Avon), 26, 106, 10.1016/j.clinbiomech.2010.08.006 Devereaux, 2005, Need for expertise based randomised controlled trials, BMJ, 330, 88, 10.1136/bmj.330.7482.88