Effect of Implant Angulation upon Retention of Overdenture Attachments

Journal of Prosthodontics - Tập 14 Số 1 - Trang 3-11 - 2005
Michael P. Gulizio1, John R. Agar2, J. Robert Kelly3, Thomas D. Taylor4
1Resident, Prosthodontics Graduate Program, University of Connecticut Health Center, Farmington, Connecticut.
2Associate Professor and Director, Prosthodontics Graduate Program, University of Connecticut Health Center, Farmington, Connecticut.
3Associate Professor, Graduate Prosthodontics Program, University of Connecticut Health Center, Farmington, Connecticut.
4Professor and Head, Department of Prosthodontics and Operative Dentistry, University of Connecticut Health Center, Farmington, Connecticut.

Tóm tắt

Introduction : Overdentures supported and retained by endosteal implants depend upon mechanical components to provide retention. Ball attachments are frequently described because of simplicity and low cost, but retentive capacity of these components may be altered by a lack of implant parallelism.

Purpose : The aim of this in vitro study was to investigate the retention of gold and titanium overdenture attachments when placed on ball abutments positioned off‐axis.

Methods and Materials : Four ball abutments were hand‐tightened onto ITI dental implants and placed in an aluminum fixture that allowed positioning of the implants at 0°, 10°, 20°, and 30° from a vertical reference axis. Gold and titanium matrices were then coupled to the ball abutments at various angles and then subjected to pull tests at a rate of 2 mm/second; the peak loads of release (maximum dislodging forces) were recorded and subjected to statistical analyses. A balanced and randomized factorial experimental design testing procedure was implemented.

Results : Statistically significant differences in retention of gold matrices were noted when ball abutments were positioned at 20° and 30°, but not at 0° and 10°. Statistically significant differences were noted among the titanium matrices employed for the testing procedure, as well as for the 4 ball abutments tested. Angle was not a factor affecting retention for titanium matrices.

Conclusions : (1) The gold matrices employed for the testing procedures exhibited consistent values in retention compared to titanium matrices, which exhibited large variability in retention. (2) Angle had an effect upon the retention of gold matrices, but not for titanium matrices.

Từ khóa


Tài liệu tham khảo

Mericske‐Stern R, 1998, Three‐dimensional force measurements with mandibular overdentures connected to implants by ball‐shaped retentive anchors. A clinical study, Int J Oral Maxillofac Implants, 13, 36

10.1007/s007840050016

Johns RB, 1992, A multicenter study of overdentures supported by Branemark implants, Int J Oral Maxillofac Implants, 7, 513

10.14219/jada.archive.1996.0032

10.1016/S0022-3913(97)70120-3

Albrektsson T, 1986, The long‐term efficacy of currently used dental implants: a review and proposed criteria of success, Int J Oral Maxillofac Implants, 1, 11

10.1016/S0022-3913(05)80331-2

Engquist B, 1988, A retrospective multicenter evaluation of osseointegrated implants supporting overdentures, Int J Oral Maxillofac Implants, 3, 129

Straumann ITI, 1997, Techno Info

10.1016/0022-3913(72)90188-6

10.1067/mpr.2001.118365

Mericske‐Stern R, 1993, Forces on implants supporting overdentures: a preliminary study of morphologic and cephalometric considerations, Int J Oral Maxillofac Implants, 8, 254

Nobelpharma, 1995, Overdenture Treatment Branemark System: Clinical Procedures, 6

Preiskel HW, 1996, Overdentures Made Easy: A Guide to Implant and Root Supported Prostheses, 212

10.1016/S0300-5712(97)87700-7

Landa LS, 2001, A prospective 2‐year clinical evaluation of overdentures attached to nonsplinted implants utilizing ERA attachments, Pract Proc Aesthet Dent, 13, 151

10.1034/j.1600-0501.2000.011S1108.x

Mericske‐Stern RD, 1997, Boucher's Prosthodontic Treatment for Edentulous Patients, 527

Parel SM, 1986, Implants and overdentures: the osseointegrated approach with conventional and compromised applications, Int J Oral Maxillofac Implants, 1, 93

10.1016/0022-3913(90)90153-4

Cooper LF, 1999, Treatment of edentulism using Astra Tech implants and ball abutments to retain mandibular overdentures, Int J Oral Maxillofac Implants, 14, 646

10.1177/00220345940730051301

10.1016/0278-2391(95)90627-4

Jemt T, 1996, A 5‐year prospective multicenter follow‐up report on overdentures supported by osseointegrated implants, Int J Oral Maxillofac Implants, 11, 291

10.1034/j.1600-0501.1998.090304.x

Wismeyer D, 1995, Overdentures supported by ITI implants: a 6.5‐year evaluation of patient satisfaction and prosthetic aftercare, Int J Oral Maxillofac Implants, 10, 744

10.1111/j.1741-2358.2002.00003.x

Donatsky O, 1993, Osseointegrated dental implants with ball attachments supporting overdentures in patients with mandibular alveolar ridge atrophy, Int J Oral Maxillofac Implants, 8, 162

10.1016/0022-3913(94)90188-0

Gotfredsen K, 2000, Implant‐supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5‐year study, Int J Prosthodont, 13, 125

Yusuf H, 1996, Observations on 25 patients treated with ball‐retained overdentures using the Astra Tech implant system, Eur J Prosthodont Restor Dent, 4, 181

Takanashi Y, 2002, Does a prosthodontist spend more time providing mandibular two‐implant overdentures than conventional dentures?, Int J Prosthodont, 15, 397

Douglas CW, 1990, Review of the literature (from Prosthodontics 21 Symposium), J Prosthet Dent Update, 24, 106