Early human experience with use of a deflectable fiberoptic endocardial visualization catheter to facilitate coronary sinus cannulation

Heart Rhythm - Tập 3 - Trang 875-878 - 2006
D.J. Anh1, Henry A. Chen1, Christian S. Eversull2, Nicholas J. Mourlas2, R. Hardwin Mead3, L. Bing Liem4, Henry H. Hsia1, Paul J. Wang1, Amin Al-Ahmad1
1Cardiac Arrythmia Service, Stanford University Medical Center, Stanford, California
2Acumen Medical, Inc., Sunnyvale, California
3Sequoia Hospital, Redwood City, California
4New Mexico Heart Institute, Albuquerque, New Mexico

Tài liệu tham khảo

Linde, 2002, Long-term benefits of biventricular pacing in congestive heart failure, J Am Coll Cardiol, 40, 111, 10.1016/S0735-1097(02)01932-0 Cazeau, 1996, Multisite pacing for end-stage heart failure, Pacing Clin Electrophysiol, 19, 1748, 10.1111/j.1540-8159.1996.tb03218.x Cazeau, 2001, Multisite Stimulation in Cardiomyopathies Study. I. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay, N Eng J Med, 344, 873, 10.1056/NEJM200103223441202 Abraham, 2002, Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure, N Eng J Med, 346, 1845, 10.1056/NEJMoa013168 Cleland, 2005, Cardiac Resynchronization–Heart Failure (CARE-HF) Study Investigators. I. The effect of cardiac resynchronization on morbidity and mortality in heart failure, N Eng J Med, 352, 1539, 10.1056/NEJMoa050496 Bristow, 2004, Comparison of medical therapy PaDiHFI. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure, N Eng J Med, 350, 2140, 10.1056/NEJMoa032423 Doshi RN, Daoud EG, Fellows C, Turk K, Duran A, Hamdan MH, Pires LA, Group PS. Left ventricular-based cardiac stimulation post AV nodal ablation evaluation (the PAVE study). J Cardiovasc Electrophysiol 1160;16:1160–1165. Alonso, 2001, Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure, Heart, 86, 405, 10.1136/heart.86.4.405 Bax, 2005, Cardiac resynchronization therapy. Part 2. Issues during and after device implantation and unresolved questions, J Am Coll Cardiol, 46, 2168, 10.1016/j.jacc.2005.09.020 Ho, 2004, A review of the coronary venous system, Heart Rhythm, 1, 107, 10.1016/j.hrthm.2003.12.001 Chiang, 1994, Major coronary sinus abnormalities, Am Heart J, 127, 1279, 10.1016/0002-8703(94)90047-7 Singh, 2005, The coronary venous anatomy, J Am Coll Cardiol, 46, 68, 10.1016/j.jacc.2005.04.017 Lemola, 2005, Topographic analysis of the coronary sinus and major cardiac veins by computed tomography, Heart Rhythm, 2, 694, 10.1016/j.hrthm.2005.04.016 Mao, 2005, Coronary venous imaging with electron beam computed tomographic angiography, Am Heart J, 150, 315, 10.1016/j.ahj.2004.09.050 Bashir, 2003, Combined use of transesophageal ECHO and fluoroscopy for the placement of left ventricular pacing leads via the coronary sinus, Pacing Clin Electrophysiol, 26, 1951, 10.1046/j.1460-9592.2003.00301.x Plotkin, 1998, Percutaneous coronary sinus cannulation guided by transesophageal echocardiography, Ann Thor Surg, 66, 2085, 10.1016/S0003-4975(98)01068-6 Artrip, 2002, Transesophageal echocardiography guided placement of a coronary sinus pacing lead, Ann Thor Surg, 74, 1254, 10.1016/S0003-4975(02)03788-8 Nazarian, 2005, Direct visualization of coronary sinus ostium and branches with a flexible steerable fiberoptic infrared endoscope, Heart Rhythm, 2, 844, 10.1016/j.hrthm.2005.04.020 Themistoclakis, 2006, Endoscopic fiberoptic assessment of balloon occlusion of the pulmonary vein ostium in humans, Heart Rhythm, 3, 44, 10.1016/j.hrthm.2005.10.005