EEG source imaging
Tóm tắt
Từ khóa
Tài liệu tham khảo
Achim, 1991, Methodological considerations for the evaluation of spatio-temporal source models, Electroencephalogr Clin Neurophysiol, 79, 227, 10.1016/0013-4694(91)90140-Y
Ahlfors, 1999, Spatiotemporal activity of a cortical network for processing visual motion revealed by MEG and fMRI, J Neurophysiol, 82, 2545, 10.1152/jn.1999.82.5.2545
Anogianakis, 1992, A consensus statement of relative merits of EEG and MEG (Editorial), Electroencephalogr Clin Neurophysiol, 82, 317, 10.1016/0013-4694(92)90001-X
Ary, 1981, Location of sources of evoked scalp potentials: corrections of skull and scalp thickness, IEEE Trans Biomed Eng, 28, 447, 10.1109/TBME.1981.324817
Babiloni, 1996, Spline Laplacian estimate of EEG potentials over a realistic magnetic resonance-constructed scalp surface model, Electroencephalogr Clin Neurophysiol, 98, 363, 10.1016/0013-4694(96)00284-2
Backus, 1970, Uniqueness in the inversion of gross earth data, Phil Trans R Soc, 266, 123, 10.1098/rsta.1970.0005
Baillet, 1997, A Bayesian approach to introducing anatomo-functional priors in the EEG/MEG inverse problem, IEEE Trans Biomed Eng, 44, 374, 10.1109/10.568913
Baillet, 2001, Electromagnetic brain mapping, IEEE Signal Processing Magazine, Nov, 14, 10.1109/79.962275
Barkley, 2003, MEG and EEG in epilepsy (Review), J Clin Neurophysiol, 20, 163, 10.1097/00004691-200305000-00002
Barnes, 2003, Statistical flattening of MEG beamformer images, Hum Brain Mapp, 18, 1, 10.1002/hbm.10072
Baumgartner, 2000, Clinical applications of magnetoencephalography (Editorial), J Clin Neurophysiol, 17, 175, 10.1097/00004691-200003000-00006
Benar, 2001, Non-uniform spatial sampling in EEG source analysis, Proc 23rd Conf IEEE-EMBS
Berg, 1994, A fast method for forward computation of multiple-shell spherical head models, Electroencephalogr Clin Neurophysiol, 90, 58, 10.1016/0013-4694(94)90113-9
Bertrand, 1991, Finite element method in brain electrical activity studies
Blanke, 1999, Visual activity in the human frontal eye field, Neuroreport, 10, 925, 10.1097/00001756-199904060-00006
Blanke, 2000, Temporal and spatial determination of EEG-seizure onset in the frequency domain, Clin Neurophysiol, 111, 763, 10.1016/S1388-2457(00)00251-0
Boon, 2000, Interictal and ictal source localization in neocortical versus medial temporal lobe epilepsy, Adv Neurol, 84, 365
Brandeis, 1992, Scopolamine effects on visual information processing, attention, and event-related potential map latencies, Psychophysiology, 29, 315, 10.1111/j.1469-8986.1992.tb01706.x
Buchner, 1995, Somatotopy of human hand somatosensory cortex revealed by dipole source analysis of early somatosensory evoked potentials and 3D NMR tomography, Electroencephalogr Clin Neurophysiol, 96, 121, 10.1016/0168-5597(94)00228-7
Bullier, 2001, Integrated model of visual processing, Brain Res Rev (Review), 36, 96, 10.1016/S0165-0173(01)00085-6
Cabeza, 2000, Imaging cognition. II. An empirical review of 275 PET and fMRI studies, J Cogn Neurosci (Review), 12, 1, 10.1162/08989290051137585
Cabrera Fernandez, 1995, Some limitations of spatio-temporal source models, Brain Topogr, 7, 87
Cuffin, 1990, Effects of head shape on EGG's and MEG's, IEEE Trans Biomed Eng, 37, 44, 10.1109/10.43614
Cuffin, 1993, Effects of local variations in skull and scalp thickness on EEG's and MEG's, IEEE Trans Biomed Eng, 40, 42, 10.1109/10.204770
Cuffin, 1996, EEG localization accuracy improvements using realistically shaped head models, IEEE Trans Biomed Eng, 43, 299, 10.1109/10.486287
Cuffin, 2001, Effects of modeling errors and EEG measurement montage on source localization accuracy, J Clin Neurophysiol, 18, 37, 10.1097/00004691-200101000-00008
Cuffin, 2001, Experimental tests of EEG source localization accuracy in realistically shaped head models, Clin Neurophysiol, 112, 2288, 10.1016/S1388-2457(01)00669-1
Cui, 1999, Neuroimage of voluntary movement: topography of the Bereitschaftspotential, a 64-channel DC current source density study, Neuroimage, 9, 124, 10.1006/nimg.1998.0388
Cui, 2000, High resolution spatiotemporal analysis of the contingent negative variation in simple or complex motor tasks and a non-motor task, Clin Neurophysiol, 111, 1847, 10.1016/S1388-2457(00)00388-6
Dale, 2000, Dynamic statistical parametric mapping: combining fMRI and MEG for high resolution imaging of cortical activity, Neuron, 26, 55, 10.1016/S0896-6273(00)81138-1
De Munck, 1988, The potential distribution in a layered anisotropic spheroidal volume conductor, J Appl Phys, 64, 461, 10.1063/1.341983
De Munck, 1993, A fast method to compute the potential in the multisphere model, IEEE Trans Biomed Eng, 40, 1166, 10.1109/10.245635
De Munck, 1991, A practical method for determining electrode positions on the head, Electroencephalogr Clin Neurophysiol, 78, 85, 10.1016/0013-4694(91)90023-W
Desmedt, 1990, Beware of the average reference in brain mapping (Review), Electroencephalogr Clin Neurophysiol Suppl, 41, 22
Devor, 2003, Coupling of total hemoglobin concentration, oxygenation, and neural activity in rat somatosensory cortex, Neuron, 39, 353, 10.1016/S0896-6273(03)00403-3
Diekmann, 1998, Localisation of epileptic foci with electric, magnetic and combined electronic models, Electroencephalogr Clin Neurophysiol, 106, 297, 10.1016/S0013-4694(97)00142-9
Dierks, 1993, Brain electrical activity in depression described by equivalent dipoles, J Affect Disord, 28, 95, 10.1016/0165-0327(93)90038-L
Dierks, 1993, Dementia of the Alzheimer type: effects on the spontaneous EEG described by dipole sources, Psychiatry Res, 50, 151, 10.1016/0925-4927(93)90027-F
Dierks, 1995, Electrical brain activity in schizophrenia described by equivalent dipoles of FFT-data, Schizophr Res, 14, 145, 10.1016/0920-9964(94)00032-4
Di Russo, 2002, Cortical sources of the early components of the visual evoked potential, Hum Brain Mapp, 15, 95, 10.1002/hbm.10010
Ducommun, 2002, Segregated processing of auditory motion and auditory location: an ERP mapping study, Neuroimage, 16, 76, 10.1006/nimg.2002.1062
Duffy, 1981, Significance probability mapping: an aid in the topographic analysis of brain electrical activity, Electroencephalogr Clin Neurophysiol, 51, 455, 10.1016/0013-4694(81)90221-2
Dumermuth, 1987, Spectral analysis of EEG background activity, vol. 1, 85
Ebersole, 1997, Defining epileptogenic foci: past, present, future, J Clin Neurophysiol, 14, 470, 10.1097/00004691-199711000-00003
Ebersole, 1999, EEG source modeling. The first word, J Clin Neurophysiol, 16, 201, 10.1097/00004691-199905000-00001
Ebersole, 1999, EEG source modeling. The last word (Review), J Clin Neurophysiol, 16, 297, 10.1097/00004691-199905000-00008
Ebersole, 2000, Sublobar localization of temporal neocortical epileptogenic foci by source modeling, Adv Neurol, 84, 353
Ebersole, 2000, Noninvasive localization of epileptogenic foci by EEG source modeling, Epilepsia, 41, S24, 10.1111/j.1528-1157.2000.tb01531.x
Engel, 2001, Dynamic predictions: Oscillations and synchrony in top-down processing, Nature Rev Neurosci, 2, 704, 10.1038/35094565
Ermer, 2001, Rapidly recomputable EEG forward models for realistic head shapes, Phys Med Biol, 46, 1265, 10.1088/0031-9155/46/4/324
Fabre-Thorpe, 1998, Rapid categorization of natural images by rhesus monkeys, Neuroreport, 9, 303, 10.1097/00001756-199801260-00023
Fallgatter, 2003, Brain electrical dysfunction of the anterior cingulate in schizophrenic patients, Psychiatry Res, 30, 37, 10.1016/S0925-4927(03)00072-6
Fender, 1987, Source localization of brain electrical activity, 355
Fletcher, 1998, Estimation of interpolation errors in scalp topographic mapping, Electroencephalogr Clin Neurophysiol, 1996, 422
Foxe, 2002, Flow of activation from V1 to frontal cortex in humans. A framework for defining ‘early’ visual processing, Exp Brain Res, 142, 139, 10.1007/s00221-001-0906-7
Foxe, 2003, Right hemisphere control of visuospatial attention: line-bisection judgments evaluated with high-density electrical mapping and source analysis, Neuroimage, 19, 710, 10.1016/S1053-8119(03)00057-0
Frei, 2001, Localization of MDMA-induced brain activity in healthy volunteers using low resolution brain electromagnetic tomography (LORETA), Hum Brain Mapp, 14, 152, 10.1002/hbm.1049
Fuchs, 1994, Generalized minimum norm least squares reconstruction algorithms, 8
Fuchs, 1999, Linear and nonlinear current density reconstructions (Review), J Clin Neurophysiol, 16, 267, 10.1097/00004691-199905000-00006
Fuchs, 2001, Boundary element method volume conductor models for EEG source reconstruction, Clin Neurophysiol, 112, 1400, 10.1016/S1388-2457(01)00589-2
Fuchs, 2002, A standardized boundary element method volume conductor model, Clin Neurophysiol, 113, 702, 10.1016/S1388-2457(02)00030-5
Gencer, 1996, Optimal reference electrode selection for electric source imaging, Electroencephalogr Clin Neurophysiol, 99, 163, 10.1016/0013-4694(96)95139-1
George, 1995, Mapping function in the human brain with magnetoencephalography, anatomical magnetic resonance imaging, and functional magnetic resonance imaging (Review), J Clin Neurophysiol, 12, 406, 10.1097/00004691-199509010-00002
Gevins, 1990, Beyond topographic mapping: towards functional–anatomical imaging with 124-channel EEGs and 3-D MRIs (Review), Brain Topogr, 3, 53, 10.1007/BF01128862
Gevins, 1991, Seeing through the skull: advanced EEGs use MRIs to accurately measure cortical activity from the scalp, Brain Topogr, 4, 125, 10.1007/BF01132769
Gonzalez Andino, 1999, Source modeling, 148
Gonzalez Andino, 2001, Non-stationary distributed source approximation: an alternative to improve localization procedures, Hum Brain Mapp, 14, 81, 10.1002/hbm.1043
Gonzalez Andino, 2004, Prediction of response speed by anticipatory high frequency (Gamma band) oscillations in the human brain (in revision), Hum Brain Mapp
Gorodnitsky, 1995, Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm, Electroencephalogr Clin Neurophysiol, 95, 231, 10.1016/0013-4694(95)00107-A
Grave de Peralta, 1994, Single dipole localization: Some numerical aspects and a practical rejection criterion for the fitted parameters, Brain Topogr, 6, 277, 10.1007/BF01211173
Grave de Peralta, 2001, Noninvasive localization of electromagnetic epileptic activity. I. Method descriptions and simulations, Brain Topogr, 14, 131, 10.1023/A:1012944913650
Grave de Peralta, 2004, Electrical neuroimaging based on biophysical constraints, Neuroimage, 21, 527, 10.1016/j.neuroimage.2003.09.051
Grave de Peralta, 2004, Improving the performance of linear inverse solutions by inverting the resolution matrix, IEEE Transaction on Biomed Eng
Grave de Peralta, 2002, Comparison of algorithms for the localization of focal sources: evaluation with simulated data and analysis of experimental data (online journal), Int J Bioelectromagn
Grave de Peralta Menendez, 2000, Discussing the capabilities of Laplacian minimization, Brain Topography, 13, 97, 10.1023/A:1026603017734
Grave de Peralta Menendez, 1998, A critical analysis of linear inverse solutions, IEEE Trans Biomed Eng, 45, 440, 10.1109/10.664200
Grave de Peralta Menendez, 1999, Backus and Gilbert method for vector fields, Hum Brain Mapp, 7, 161, 10.1002/(SICI)1097-0193(1999)7:3<161::AID-HBM2>3.0.CO;2-#
Grave de Peralta Menendez, 1996, Figures of merit to compare linear distributed inverse solutions, Brain Topogr, 9, 117, 10.1007/BF01200711
Grave de Peralta Menendez, 1997, Linear inverse solutions with optimal resolution kernels applied to electromagnetic tomography, Hum Brain Mapp, 5, 454, 10.1002/(SICI)1097-0193(1997)5:6<454::AID-HBM6>3.0.CO;2-2
Grave de Peralta Menendez, 2000, Imaging the electrical activity of the brain: ELECTRA, Hum Brain Mapp, 9, 1, 10.1002/(SICI)1097-0193(2000)9:1<1::AID-HBM1>3.0.CO;2-#
Greenblatt, 1993, Probabilistic reconstruction of multiple sources in the neuroelectromagnetic inverse problem, Inverse Prob, 9, 271, 10.1088/0266-5611/9/2/008
Gross, 2001, Dynamic imaging of coherent sources: studying neural interactions in the human brain, Proc Nat Acad Sci USA, 98, 694, 10.1073/pnas.98.2.694
Hämäläinen, 1995, Discrete and distributed source estimates, vol. 6, 9
Hämäläinen, MS, Ilmoniemi, RJ. Interpreting measured magnetic fields of the brain: estimates of current distributions. Technical report TKK-F-A559, Helsinki University of Technology, Espoo; 1984.
Hämäläinen, 1994, Interpreting magnetic fields of the brain—minimum norm estimates, Med Biol Eng Comput, 32, 35, 10.1007/BF02512476
Hämäläinen, 1989, Realistic conductor geometry model of the human head for interpretation of neuromagnetic data, IEEE Trans Biomed Eng, 36, 165, 10.1109/10.16463
Hämäläinen, 1993, Magneto-encephalography: theory, instrumentation, and applications to noninvasive studies of the working human brain, Rev Mod Phys, 65, 413, 10.1103/RevModPhys.65.413
Harmony, 1995, Frequency source analysis in patients with brain lesions, Brain Topogr, 8, 109, 10.1007/BF01199774
Hassaina, 1994, Scalp potential and current density mapping with an enhanced spherical spline interpolation, Med Prog Technol, 20, 23
Hauk, 2002, Comparison of data transformation procedures to enhance topographical accuracy in time-series analysis of the human EEG, J Neurosci Methods, 30, 111, 10.1016/S0165-0270(01)00484-8
He, 2002, High-resolution spatio-temporal functional neuroimaging of brain activity (Review), Crit Rev Biomed Eng, 30, 283, 10.1615/CritRevBiomedEng.v30.i456.30
He, 2001, High-resolution EEG a new realistic geometry spline Laplacian estimation technique, Clin Neurophysiol, 112, 845, 10.1016/S1388-2457(00)00546-0
He, 2002, An equivalent current source model and Laplacian weighted minimum norm current estimates of brain electrical activity, IEEE Trans Biomed Eng, 49, 277, 10.1109/10.991155
Helmholtz, 1853, Ueber einige Gesetze der Vertheilung elektrischer Ströme in körperlichen Leitern mit Anwendung aud die thierisch-elektrischen Versuche, Ann Physik und Chemie, 9, 211, 10.1002/andp.18531650603
Hoekema, 2003, Measurement of the conductivity of skull, temporarily removed during epilepsy surgery, Brain Topogr, 16, 29, 10.1023/A:1025606415858
Huang, 1999, A sensor-weighted overlapping-sphere head model and exhaustive head model comparison for MEG, Phys Med Biol, 44, 423, 10.1088/0031-9155/44/2/010
Huang, 2000, Discrimination of Alzheimer's disease and mild cognitive impairment by equivalent EEG sources: a cross-sectional and longitudinal study, Clin Neurophysiol, 111, 1961, 10.1016/S1388-2457(00)00454-5
Huppertz, 2001, Cortical current density reconstruction of interictal epileptiform activity in temporal lobe epilepsy, Clin Neurophysiol, 112, 1761, 10.1016/S1388-2457(01)00588-0
Huppertz, 2001, Localization of interictal delta and epileptiform EEG activity associated with focal epileptogenic brain lesions, Neuroimage, 13, 15, 10.1006/nimg.2000.0680
Ioannides, 2000, Real time processing of affective and cognitive stimuli in the human brain extracted from MEG signals, Brain Topogr, 13, 11, 10.1023/A:1007878001388
Isotani, 2001, Source localization of EEG activity during hypnotically induced anxiety and relaxation, Int J Psychophysiol, 41, 143, 10.1016/S0167-8760(00)00197-5
John, 2002, The neurophysics of consciousness (Review), Brain Res Rev, 39, 1, 10.1016/S0165-0173(02)00142-X
Junghöfer, 1999, The polar average reference effect: a bias in estimating the head surface integral in EEG recording, Clin Neurophysiol, 110, 1149, 10.1016/S1388-2457(99)00044-9
Khateb, 2000, New insights into the Stroop effect: a spatio-temporal analysis of electric brain activity, Neuroreport, 26, 1849, 10.1097/00001756-200006260-00010
Khateb, 2001, The time course of semantic category processing in the cerebral hemispheres: an electrophysiological study, Cogn Brain Res, 10, 251, 10.1016/S0926-6410(00)00042-2
Khateb, 2003, Processing of semantic categorical and associative relations: an ERP mapping study, Int J Psychophysiol, 49, 41, 10.1016/S0167-8760(03)00076-X
Khosla, 1999, Spatial mislocalization of EEG electrodes: effects on accuracy of dipole estimation, Clin Neurophysiol, 110, 261, 10.1016/S0013-4694(98)00121-7
King, 2000, Magnetoencephalography in neocortical epilepsy (Review), Adv Neurol, 84, 415
Kinoshita, 1994, Diazepam and sulpiride effects on frequency domain EEG source locations, Neuropsychobiology, 30, 126, 10.1159/000119147
Kobayashi, 2002, Systematic source estimation of spikes by a combination of independent component analysis and RAP-MUSIC. I. Principles and simulation study, Clin Neurophysiol, 113, 713, 10.1016/S1388-2457(02)00046-9
Kobayashi, 2003, A simulation study of the error in dipole source localization for EEG spikes with a realistic head model, Clin Neurophysiol, 114, 1069, 10.1016/S1388-2457(03)00064-6
Koenig, 2002, Millisecond by millisecond, year by year: normative EEG microstates and developmental stages, NeuroImage, 16, 41, 10.1006/nimg.2002.1070
Koles, 1998, EEG source localization: implementing the spatio-temporal decomposition approach, Electroencephalogr Clin Neurophysiol, 107, 343, 10.1016/S0013-4694(98)00084-4
Korvenoja, 1999, Activation of multiple cortical areas in response to somatosensory stimulation: combined magnetoencephalographic and functional magnetic resonance imaging, Hum Brain Mapp, 8, 13, 10.1002/(SICI)1097-0193(1999)8:1<13::AID-HBM2>3.0.CO;2-B
Kounios, 2001, Cognitive association formation in human memory revealed by spatiotemporal brain imaging, Neuron, 29, 297, 10.1016/S0896-6273(01)00199-4
Krings, 1998, Accuracy of electroencephalographic dipole localization of epileptiform activities associated with focal brain lesions, Ann Neurol, 44, 76, 10.1002/ana.410440114
Krings, 1999, Accuracy of EEG dipole source localization using implanted sources in the human brain, Clin Neurophysiol, 110, 106, 10.1016/S0013-4694(98)00106-0
Laehy, 1996
Lagerlund, 1993, Determination of 10–20 system electrode locations using magnetic resonance image scanning with markers, Electroencephalogr Clin Neurophysiol, 86, 7, 10.1016/0013-4694(93)90062-Z
Lantz, 1996, Simultaneous intracranial and extracranial recording of interictal epileptiform activity in patients with drug resistant partial epilepsy: patterns of conduction and results from dipole reconstructions, Electroencephalogr Clin Neurophysiol, 99, 69, 10.1016/0921-884X(96)95686-6
Lantz, 1997, Extracranial localization of intracranial interictal epileptiform activity using LORETA (low resolution electromagnetic c tomography), Electroencephalogr Clin Neurophysiol, 102, 414, 10.1016/S0921-884X(96)96551-0
Lantz, 1999, Frequency domain EEG source localization of ictal epileptiform activity in patients with partial complex epilepsy of temporal lobe origin, Clin Neurophysiol, 110, 176, 10.1016/S0013-4694(98)00117-5
Lantz, 2001, Noninvasive localization of electromagnetic epileptic activity. II. Demonstration of sublobar accuracy in patients with simultaneous surface and depth recordings, Brain Topogr, 14, 139, 10.1023/A:1012996930489
Lantz, 2001, Space oriented segmentation and 3-dimensional source reconstruction of ictal EEG-patterns, Clin Neurophysiol, 112, 688, 10.1016/S1388-2457(01)00479-5
Lantz, 2003, Epileptic source localization with high density EEG: how many electrodes are needed?, Clin Neurophysiol, 114, 63, 10.1016/S1388-2457(02)00337-1
Lantz, 2003, Propagation of interictal epileptiform activity can lead to erroneous source localizations: a 128 channel EEG mapping study, J Clin Neurophysiol, 20, 311, 10.1097/00004691-200309000-00003
Laskaris, 2003, Single-trial variability in early visual neuromagnetic responses: an explorative study based on the regional activation contributing to the N70m peak, Neuroimage, 20, 765, 10.1016/S1053-8119(03)00367-7
Lawson, 1974
Le, 1998, A rapid method for determining standard 10/10 electrode positions for high resolution EEG studies, Electroencephalogr Clin Neurophysiol, 106, 554, 10.1016/S0013-4694(98)00004-2
Lehmann, 1987, Principles of spatial analysis, 309
Lehmann, 1990, Intracerebral dipole source localization for FFT power maps, Electroencephalogr Clin Neurophysiol, 76, 271, 10.1016/0013-4694(90)90022-C
Lehmann, 1980, Reference-free identification of components of checkerboard-evoked multichannel potential fields, Electroencephalogr Clin Neurophysiol, 48, 609, 10.1016/0013-4694(80)90419-8
Lehmann, 1993, Source localization of brain electric field frequency bands during conscious, spontaneous, visual imagery and abstract thought, Cogn Brain Res, 1, 203, 10.1016/0926-6410(93)90003-N
Lehmann, 1998, Brain electric microstates and momentary conscious mind states as building blocks of spontaneous thinking. I. Visual imagery and abstract thoughts, Int J Psychophysiol, 29, 1, 10.1016/S0167-8760(97)00098-6
Lin, 1996, Advances in time-frequency analysis of biomedical signals (Review), Crit Rev Biomed Eng, 24, 1, 10.1615/CritRevBiomedEng.v24.i1.10
Liu, 1998, Spatiotemporal imaging of human brain activity using functional MRI constrained magnetoencephalography data: Monte Carlo simulations, Proc Natl Acad Sci USA, 95, 8945, 10.1073/pnas.95.15.8945
Liu, 1999, Single trial analysis of neurophysiological correlates of the recognition of complex objects and facial expressions of emotion, Brain Topogr, 11, 291, 10.1023/A:1022258620435
Liu, 2002, Monte Carlo simulation studies of EEG and MEG localization accuracy, Hum Brain Mapp, 16, 47, 10.1002/hbm.10024
Logothetis, 2001, Neurophysiological investigation of the basis of the fMRI signal, Nature, 412, 150, 10.1038/35084005
Lubar, 2003, Low-resolution electromagnetic tomography (LORETA) of cerebral activity in chronic depressive disorder, Int J Psychophysiol, 49, 175, 10.1016/S0167-8760(03)00115-6
Lütkenhöner, 1992, Frequency-domain localization of intracerebral dipolar sources, Electroencephalogr Clin Neurophysiol, 82, 112, 10.1016/0013-4694(92)90153-9
Lütkenhöner, 1997, The resolution-field concept, Electroencephalogr Clin Neurophysiol, 102, 326, 10.1016/S0013-4694(96)96590-6
Malmivuo, 1997, Sensitivity distributions of EEG and MEG measurements, IEEE Trans Biomed Eng, 44, 196, 10.1109/10.554766
Martinez, 2001, Electrophysiological analysis of cortical mechanisms of selective attention to high and low spatial frequencies, Clin Neurophysiol, 112, 1980, 10.1016/S1388-2457(01)00660-5
Meijs, 1987, On the magnetic field distribution in a realistically shaped compartment model of the head, Electroencephalogr Clin Neurophysiol, 66, 286, 10.1016/0013-4694(87)90078-2
Mencke, 1989
Menninghaus, 1994, Localization of a dipolar source in a skull phantom: realistic versus spherical model, IEEE Trans Biomed Eng, 41, 986, 10.1109/10.324531
Menon, 1997, Combined event-related fMRI and EEG evidence for temporal-parietal cortex activation during target detection, Neuroreport, 8, 3029, 10.1097/00001756-199709290-00007
Merlet, 1999, Reliability of dipole models of epileptic spikes, Clin Neurophysiol, 110, 1013, 10.1016/S1388-2457(98)00062-5
Merlet, 2001, Dipole modeling of scalp electroencephalogram epileptic discharges: correlation with intracerebral fields, Clin Neurophysiol, 112, 414, 10.1016/S1388-2457(01)00458-8
Merlet, 1996, Source propagation of interictal spikes in temporal lobe epilepsy. Correlations between spike dipole modelling and [18F]fluorodeoxyglucose PET data, Brain, 119, 377, 10.1093/brain/119.2.377
Michel, 1992, Localization of the sources of EEG delta, theta, alpha and beta frequency bands using the FFT dipole approximation, Electroencephalogr Clin Neurophysiol, 82, 38, 10.1016/0013-4694(92)90180-P
Michel, 1993, EEG reactivity in high and low symptomatic schizophrenics, using source modelling in the frequency domain, Brain Topogr, 5, 389, 10.1007/BF01128696
Michel, 1995, Frequency domain source localization shows state-dependent diazepam effects in 47-channel EEG, J Neural Transm Gen Sect, 99, 157, 10.1007/BF01271476
Michel, 1999, Spatiotemporal EEG analysis and distributed source estimation in presurgical epilepsy evaluation (Review), J Clin Neurophysiol, 16, 239, 10.1097/00004691-199905000-00005
Michel, 1999, Spatio-temporal dynamics of human cognition, News Physiol Sci, 14, 206
Michel, 2001, Electric source imaging of human cognitive brain functions (Review), Brain Res Rev, 36, 108, 10.1016/S0165-0173(01)00086-8
Michel, 2004, 128-channel EEG source imaging in epilepsy: clinical yield and localization precision, J Clin Neurophysiol, 21, 71, 10.1097/00004691-200403000-00001
Michel CM, Seeck M, Murray MM. The speed of visual cognition. In: Hallett M, Phillips L, Schomer D, Mark J, editors. Adv Clin Neurophysiol 2004, Vol. 57, in press.
Miller, 1990, Finite element analysis of bioelectric phenomena (Review), Crit Rev Biomed Eng, 18, 207
Miltner W, Braun C, Johnson Jr R, Simpson GV, Ruchkin DS. A test of brain electrical source analysis (BESA): a simulation study. Electroencephalogr Clin Neurophysiol 1994;91:295–310.
Mitiche, 1988, On smoothness of a vector field-application to optical flow, IEEE Transactions on Pattern Analysis and Machine Intelligence, 10, 943, 10.1109/34.9116
Morand, 2000, Electrophysiological evidence for fast visual processing through the human koniocellular pathway when stimuli move, Cereb Cortex, 10, 817, 10.1093/cercor/10.8.817
Mosher, 1992, Multiple dipole modeling and localization from spatio-temporal MEG data, IEEE Trans Biomed Eng, 39, 541, 10.1109/10.141192
Mosher, 1998, Recursive MUSIC: a framework for EEG and MEG source localization, IEEE Trans Biomed Eng, 45, 1342, 10.1109/10.725331
Murray, 2002, The spatiotemporal dynamics of illusory contour processing: combined high-density electrical mapping, source analysis, and functional magnetic resonance imaging, J Neurosci, 22, 5055, 10.1523/JNEUROSCI.22-12-05055.2002
Murray, 2004, Rapid discrimination of visual and multisensory memories revealed by electrical neuroimaging, Neuroimage, 21, 125, 10.1016/j.neuroimage.2003.09.035
Murray, 2004, Grabbing your ear: rapid auditory-somatosensory multisensory interactions in low-level sensory cortices are not constrained by stimulus alignment, Cerebral Cortex, 10.1093/cercor/bhh197
Nunez, 1981
Ortigue, 2004, Electrical neuroimaging reveals early generator modulation to emotional words, Neuroimage, 21, 1242, 10.1016/j.neuroimage.2003.11.007
Park, 2002, Statistical parametric mapping of LORETA using high density EEG and individual MRI: application to mismatch negativities in schizophrenia, Hum Brain Mapp, 17, 168, 10.1002/hbm.10059
Pascual-Marqui, 1999, Review of methods for solving the EEG inverse problem, International Journal of Bioelectromagnetism, 1, 75
Pascual-Marqui, 2002, Standardized low resolution brain electromagnetic tomography (sLORETA): technical details, Methods Findings Exp Clin Pharmacol, 24D, 5
Pascual-Marqui, 1993, Comparison of topographic maps and the reference electrode: comments on two papers by Desmedt and collaborators, Electroencephalogr Clin Neurophysiol, 88, 534
Pasqual-Marqui, 1994, Low resolution electromagnetic tomography: a new method to localize electrical activity in the brain, Int J Psychophysiol, 18, 49, 10.1016/0167-8760(84)90014-X
Pascual-Marqui, 1995, Segmentation of brain electrical activity into microstates: model estimation and validation, IEEE Trans Biomed Eng, 42, 658, 10.1109/10.391164
Pataraia, 2002, Magnetoencephalography in presurgical epilepsy evaluation (Review), Neurosurg Rev, 25, 141, 10.1007/s10143-001-0197-2
Pegna, 1997, Unraveling the cerebral dynamics of mental imagery, Hum Brain Mapp, 5, 410, 10.1002/(SICI)1097-0193(1997)5:6<410::AID-HBM2>3.0.CO;2-6
Pegna, 2002, Neural processing of illusory and real contours revealed by high-density ERP mapping, Neuroreport, 13, 965, 10.1097/00001756-200205240-00013
Perrin, 1987, Mapping of scalp potentials by surface spline interpolation, Electroencephalogr Clin Neurophysiol, 66, 75, 10.1016/0013-4694(87)90141-6
Perrin, 1989, Spherical splines for scalp potential and current density mapping, Electroencephalogr Clin Neurophysiology, 72, 184, 10.1016/0013-4694(89)90180-6
Perrin, 1990, Precautions in topographic mapping and in evoked potential map reading (Review), J Clin Neurophysiol, 7, 498, 10.1097/00004691-199010000-00005
Phillips, 1997, MEG-based imaging of focal neuronal current sources, IEEE Trans Med Imaging, 16, 338, 10.1109/42.585768
Phillips, 2002, Systematic regularization of linear inverse solutions of the EEG source localization problem, Neuroimage, 17, 287, 10.1006/nimg.2002.1175
Picton, 2000, Guidelines for using human event-related potentials to study cognition: recording standards and publication criteria, Psychophysiology, 37, 127, 10.1111/1469-8986.3720127
Plonsey, 1982, The nature of sources of bioelectric and biomagnetic fields, Biophys J, 39, 309, 10.1016/S0006-3495(82)84521-9
Praamstra, 2003, Attention and movement-related motor cortex activation: a high-density EEG study of spatial stimulus-response compatibility, Cogn Brain Res, 16, 309, 10.1016/S0926-6410(02)00286-0
Riedel, 2003, Dipole source analysis of auditory brain stem responses evoked by lateralized clicks, Z Med Phys, 13, 75, 10.1078/0939-3889-00147
Robinson, 1999, Functional neuroimaging by synthetic aperture magnetometry (SAM), 302
Rodin, 1997, Displaying electroencephalographic dipole sources on magnetic resonance images, J Neuroimaging, 7, 106, 10.1111/jon199772106
Rohrbaugh, 1983, Sensory and motor aspects of the contingent negative variation, 269
Rosenow, 2001, Presurgical evaluation of epilepsy (Review), Brain, 124, 1683, 10.1093/brain/124.9.1683
Roth, 1993, How well does a three-sphere model predict positions of dipoles in a realistically shaped head?, Electroencephalogr Clin Neurophysiol, 87, 175, 10.1016/0013-4694(93)90017-P
Scherg, 1986, Evoked dipole source potentials of the human auditory cortex, Electroencephalogr Clin Neurophysiol, 65, 344, 10.1016/0168-5597(86)90014-6
Scherg, 1999, Multiple source analysis of interictal spikes: goals, requirements, and clinical value (Review), J Clin Neurophysiol, 16, 214, 10.1097/00004691-199905000-00003
Scherg, 2002, Advanced tools for digital EEG review: virtual source montages, whole-head mapping, correlation, and phase analysis, J Clin Neurophysiol, 19, 91, 10.1097/00004691-200203000-00001
Schmidt, 1999, Bayesian inference applied to the electromagnetic inverse problem, Hum Brain Mapp, 7, 195, 10.1002/(SICI)1097-0193(1999)7:3<195::AID-HBM4>3.0.CO;2-F
Schnider, 2003, Spontaneous confabulation and the adaptation of thought to ongoing reality (Review), Nat Rev Neurosci, 4, 662, 10.1038/nrn1179
Schroeder, 1998, A spatiotemporal profile of visual system activation revealed by current source density analysis in the awake macaque, Cereb Cortex, 8, 575, 10.1093/cercor/8.7.575
Seeck, 1997, Evidence for rapid face recognition from human scalp and intracranial electrodes, Neuroreport, 8, 2749, 10.1097/00001756-199708180-00021
Seeck M, Lazeyras F, Michel CM, Blanke O, Gericke G, Ives J, Delavelle J, Golay X, Haenggeli CA, de Tribolet N, Landis T. Non-invasive epileptic focus localization using EEG-triggered functional MRI and electromagnetic tomography. Electroencephalogr Clin Neurophysiol, 1998;106: 508–12.
Sekihara, 1999, Time-frequency MEG-MUSIC algorithm, IEEE Trans Med Imaging, 18, 92, 10.1109/42.750262
Sekihara, 2001
Seri, 1998, Frontal lobe epilepsy associated with tuberous sclerosis: electroencephalographic-magnetic resonance image fusioning, J Child Neurol, 13, 33, 10.1177/088307389801300106
Simpson, 1995, Dynamic neuroimaging of brain function (Review), J Clin Neurophysiol, 12, 432, 10.1097/00004691-199509010-00003
Skrandies, 1989, Data reduction of multichannel fields: global field power and principal component analysis, Brain Topogr, 2, 73, 10.1007/BF01128845
Skrandies, 2003, Topographical analysis of electric brain activity: methodological aspects, 401
Soong, 1993, Systematic comparisons of interpolation techniques in evoked potential map reading, J Clin Neurophysiol, 87, 185, 10.1016/0013-4694(93)90018-Q
Soufflet, 1991, A statistical evaluation of the main interpolation methods applied to 3-dimensional EEG mapping, Electroencephalogr Clin Neurophysiol, 79, 393, 10.1016/0013-4694(91)90204-H
Spencer, 2001, Spatiotemporal analysis of the late ERP responses to deviant stimuli, Psychophysiology, 38, 343, 10.1111/1469-8986.3820343
Spinelli, 2000, Electromagnetic inverse solutions in anatomically constrained spherical head models, Brain Topogr, 13, 115, 10.1023/A:1026607118642
Spitzer, 1989, A method for determining optimal interelectrode spacing for cerebral topographic mapping, Electroencephalogr Clin Neurophysiol, 72, 355, 10.1016/0013-4694(89)90072-2
Srinivasan, 1996, Spatial sampling and filtering of EEG with spline laplacians to estimate cortical potentials, Brain Topogr, 8, 355, 10.1007/BF01186911
Srinivasan, 1998, Estimating the spatial Nyquist of the human EEG, Behav Res Meth Inst Comp, 30, 8, 10.3758/BF03209412
Stok, 1987, The influence of model parameters on EEG/MEG single dipole source estimation, IEEE Trans Biomed Eng, 34, 421, 10.1109/TBME.1987.326090
Suarez, 2000, Relating induced changes in EEG signals to orientation of visual stimuli using the ESI-256 machine, Biomed Sci Instrum, 36, 33
Taniguchi, 2000, Movement-related desynchronization of the cerebral cortex studied with spatially filtered magnetoencephalography, Neuroimage, 12, 298, 10.1006/nimg.2000.0611
Tesche, 1993, A comparison of the localization of spontaneous neuromagnetic activity in the frequency and time domains, Electroencephalogr Clin Neurophysiol, 87, 408, 10.1016/0013-4694(93)90155-O
Thees, 2003, Dipole source localization and fMRI of simultaneously recorded data applied to somatosensory categorization, Neuroimage, 18, 707, 10.1016/S1053-8119(02)00054-X
Thévenet, 1991, The finite element method for the realistic head model of electrical brain activities: Preliminary results, Clin Phys Physiol Meas, 12, 89, 10.1088/0143-0815/12/A/017
Thut, 1999, Evidence for interhemispheric motor-level transfer in a simple reaction time task: an EEG study, Exp Brain Res, 128, 256, 10.1007/s002210050846
Thut, 2000, Internally driven vs. externally cued movement selection: a study on the timing of brain activity, Cogn Brain Res, 9, 261, 10.1016/S0926-6410(00)00004-5
Thut, 2000, Visually induced activity in human frontal motor areas during simple visuomotor performance, Neuroreport, 11, 2843, 10.1097/00001756-200009110-00004
Tomberg, 1990, Inadequacy of the average reference for the topographic mapping of focal enhancements of brain potentials, Electroencephalogr Clin Neurophysiol, 77, 259, 10.1016/0168-5597(90)90064-K
Towle, 1993, The spatial location of EEG electrodes: locating the best-fitting sphere relative to cortical anatomy, Electroencephalogr Clin Neurophysiol, 86, 1, 10.1016/0013-4694(93)90061-Y
Trujillo-Barreto, 2004, Bayesian model averaging in EEG/MEG imaging, NeuroImage, 10.1016/j.neuroimage.2003.11.008
Tsuno, 2002, Spatial organization of EEG activity from alertness to sleep stage 2 in old and younger subjects, J Sleep Res, 11, 43, 10.1046/j.1365-2869.2002.00288.x
Tucker, 1993, Spatial sampling of head electrical fields: the geodesic sensor net, Electroencephalogr Clin Neurophysiol, 87, 154, 10.1016/0013-4694(93)90121-B
Uutela, 1998, Global optimization in the localization of neuromagnetic sources, IEEE Trans Biomed Eng, 45, 716, 10.1109/10.678606
Van Hoey, 2000, EEG dipole source localization using artificial neural networks, Phys Med Biol, 45, 997, 10.1088/0031-9155/45/4/314
Van Rumste, 2002, Comparison of performance of spherical and realistic head models in dipole localization from noisy EEG, Med Eng Phys, 24, 403, 10.1016/S1350-4533(02)00036-X
Vanrumste, 2002, Comparison of performance of spherical and realistic head models in dipole localization from noisy EEG, Med Eng Phys, 24, 403, 10.1016/S1350-4533(02)00036-X
Van Veen, 1997, Localization of brain electric activity via linearly constrained minimum variance spatial filtering, IEEE Trans Biomed Eng, 44, 867, 10.1109/10.623056
Vitacco, 2002, Correspondence of event-related potential tomography and functional magnetic resonance imaging during language processing, Hum Brain Mapp, 17, 4, 10.1002/hbm.10038
Vrba, 2001, Signal processing in magnetoencephalography (Review), Methods, 25, 249, 10.1006/meth.2001.1238
Waberski, 2000, Source reconstruction of mesial-temporal epileptiform activity: comparison of inverse techniques, Epilepsia, 41, 1574, 10.1111/j.1499-1654.2000.001574.x
Waberski, 2002, Spatiotemporal imaging of electrical activity related to attention to somatosensory stimulation, Neuroimage, 17, 1347, 10.1006/nimg.2002.1222
Wang, 2001, The influence of electrode location errors on EEG dipole source localization with a realistic head model, Clin Neurophysiol, 112, 1777, 10.1016/S1388-2457(01)00594-6
Wang, 1996, An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head, IEEE Trans Biomed Eng, 43, 627, 10.1109/10.495282
Whittingstall, 2003, Effects of dipole position, orientation and noise on the accuracy of EEG source localization, Biomed Eng Online, 2, 14, 10.1186/1475-925X-2-14
Wikswo, 1993, The future of EEG and MEG: a review article, Electroencephalogr Clin Neurophysiol, 87, 1, 10.1016/0013-4694(93)90169-V
Williamson, 1991, Advantages and limitations of magnetic source imaging (Review), Brain Topogr, 4, 169, 10.1007/BF01132773
Yan, 1991, Finite-element model of human head: scalp potentials due to dipole sources, Med Biol Eng Comput, 29, 475, 10.1007/BF02442317
Yoo, 1997, 3D localization of surface 10–20 EEG electrodes on high resolution anatomical MR images, Electroencephalogr Clin Neurophysiol, 102, 335, 10.1016/S0013-4694(96)95088-9
Yvert, 1995, Improved forward EEG calculations using local mesh refinement of realistic head geometries, Electroencephalogr Clin Neurophysiol, 95, 381, 10.1016/0013-4694(95)00120-N
Yvert, 1996, Improved dipole localization using local mesh refinement of realistic head geometries: an EEG simulation study, Electroencephalogr Clin Neurophysiol, 99, 79, 10.1016/0921-884X(96)95691-X
Zanow, 1995, Individually shaped volume conductor models of the head in source localisation, Med Biol Eng Comput, 33, 582, 10.1007/BF02522518
Zhang, 1995, A fast method to compute surface potentials generated by dipoles within multilayer anisotropic spheres, Phys Med Biol, 40, 335, 10.1088/0031-9155/40/3/001
Zhang, 1993, Insidious errors in dipole localization parameters at a single time-point due to model misspecification of number of shells, Electroencephalogr Clin Neurophysiol, 88, 1, 10.1016/0168-5597(93)90022-H