Dynamic monitoring of [11C]diprenorphine in rat brain using a prototype positron imaging device

Journal of Neuroscience Methods - Tập 40 - Trang 223-232 - 1991
Suren Rajeswaran1, Susan P. Hume1, Jill E. Cremer1, John Young2, Dale L. Bailey1, John Ashburner1, Sajinder K. Luthra1, Anthony K.P. Jones1, Terry Jones1
1MRC Cyclotron Unit, Hammersmith Hospital, London W12 0HS U.K.
2CTI Group Inc., Knoxville, TN 37922 U.S.A.

Tài liệu tham khảo

Burnham, 1984, A stationary positron emission ring tomograph using BGO detector and analog readout, IEEE Trans. Nucl. Sci., 31, 632, 10.1109/TNS.1984.4333333 Cunningham, 1991, Compartmental analysis of diprenorphine binding to opiate receptors in vivo and its comparision with equilibrium data in vitro, J. Cereb. Blood Flow Metab., 11, 1, 10.1038/jcbfm.1991.1 Digby, 1989, A multi-plane high-resolution PET system for animal studies, J. Cereb. Blood Flow Metab., 9, S236.1 Digby, 1990, Detector shielding and geometric design factors for a high-resolution PET system, IEEE Trans. Nucl. Sci., 37, 664, 10.1109/23.106695 Eriksson, 1990, Positron emission tomography — a new technique for the studies of the central nervous system, J. Microscopy, 157, 305, 10.1111/j.1365-2818.1990.tb02968.x Frost, 1989, Measurement of [11C]carfentanil and [11C]diprenorphine binding to opiate receptors in temporal lobe epilepsy by PET, J. Cereb. Blood Flow Metab., 9, S60 Hamacher, 1986, Efficient stereospecific synthesis of no-carrier-added 2-[18 F]-fluoro-2-deoxy-d-glucose using aminopolyether supported nucleophilic substitution, J. Nucl. Med., 27, 235 Hoffman, 1981, Quantitation in positron emission computed tomography. 4. Effect of accidental coincidences, J. Comput. Assist. Tomogr., 3, 391, 10.1097/00004728-198106000-00015 Inoue, 1991, Difference in in vivo receptor binding between [3H]N-methyl-spiperone and [3H]raclopride in reserpine-treated mouse brain, J. Neural Trans., 85, 1, 10.1007/BF01244652 Jones, 1988, Regional cerebral opioid receptor studies with [11C]diprenorphine in normal volunteers, J. Neurosci. Methods, 23, 121, 10.1016/0165-0270(88)90184-7 Lockwood, 1981, Serial measurements of positron-emitting isotope activity in rat brain, Stroke, 12, 173, 10.1161/01.STR.12.2.173 Luthra, 1991, Improved and automated ‘one-pot’ radiosynthesis of [11C]diprenorphine and [11C]buprenorphine, J. Label. Compd. Radiopharm., 30, 258 Nakai, 1987, Simultaneous in vivo measurement of lumped constants and rate constants in experimental cerebral ischemia using F-18 FDG, Stroke, 18, 158, 10.1161/01.STR.18.1.158 Perry, 1980, Opiate antagonist receptor binding in vivo evidence for a new receptor binding model, Brain Res., 199, 49, 10.1016/0006-8993(80)90229-2 Rajeswaran, 1991, 2D and 3D imaging of small animals and the human radial artery with a high resolution detector for, PET, IEEE Trans. Med. Imaging Redies, 1987, In vivo measurement of [18F]fluorodeoxyglucose rate constants in rat brain by external coincidence counting, Neuroscience, 22, 593, 10.1016/0306-4522(87)90356-3 Robb, 1989, Interactive display and analysis of 3-D medical images, IEEE Trans. Med. Imaging, 8, 217, 10.1109/42.34710 Seeger, 1984, In vivo autoradiography: visualization of stress-induced changes in opiate receptor occupancy in the rat brain, Brain Res., 305, 303, 10.1016/0006-8993(84)90436-0 Takagi, 1984, Measurement of cerebral blood flow in the rat with intravenous injection of [11C]butanol by external coincidence counting: a repeatable and noninvasive method in the brain, J. Cereb. Blood Flow Metab., 4, 275, 10.1038/jcbfm.1984.38 Tomitani, 1985, Development of a high resolution positron CT for animal studies, IEEE Trans. Nucl. Sci., 32, 822, 10.1109/TNS.1985.4336948 Yamashita, 1990, High resolution block detectors for PET, IEEE Trans. Nucl. Sci., 37, 589, 10.1109/23.106682