Duodenoscope-related infections: Overview and epidemiology
Tài liệu tham khảo
Everhart, 2008, The burden of digestive disease in the United States
Petersen, 2017, Multisociety guideline on reprocessing flexible GI endoscopes: 2016 update, Gastrointest Endosc, 85, 282, 10.1016/j.gie.2016.10.002
Nelson, 2003, Infectious disease complications of GI endoscopy: part II, exogenous infections, Gastrointest Endosc, 57, 695, 10.1067/mge.2003.202
Spach, 1993, Transmission of infection by gastrointestinal endoscopy and bronchoscopy, Ann Intern Med, 118, 117, 10.7326/0003-4819-118-2-199301150-00008
Kovaleva, 2013, Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy, Clin Microbiol Rev, 26, 231, 10.1128/CMR.00085-12
Muscarella, 2001, Recommendations for preventing hepatitis C virus infection: analysis of a Brooklyn endoscopy clinic's outbreak, Infect Control Hosp Epidemiol, 22, 669, 10.1086/503391
2008, Acute hepatitis C virus infections attributed to unsafe injection practices at an endoscopy clinic Nevada, 2007, MMWR, 513
Schaefer, 2010, Infection control assessment of ambulatory surgical centers, JAMA, 303, 2273, 10.1001/jama.2010.744
Manufacturer and User-Facility Device Experience (MAUDE) database [Internet]. [cited January 20, 2019]. Available from: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfmaude/search.cfm
Dirlam Langlay, 2013, Reported gastrointestinal endoscope reprocessing lapses: the tip of the iceberg, Am J Infect Control, 41, 1188, 10.1016/j.ajic.2013.04.022
Rutala, 2016, Disinfection and sterilization in health care facilities: an overview and current issues, Infect Dis Clin North Am, 30, 609, 10.1016/j.idc.2016.04.002
Aumeran, 2010, Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography, Endoscopy, 42, 895, 10.1055/s-0030-1255647
Epstein, 2014, New Delhi metallo-beta-lactamase-producing carbapenem-resistant Escherichia coli associated with exposure to duodenoscopes, JAMA, 312, 1447, 10.1001/jama.2014.12720
Wendorf, 2015, Endoscopic retrograde cholangiopancreatography-associated AmpC Escherichia coli outbreak, Infect Control Hosp Epidemiol, 36, 634, 10.1017/ice.2015.66
Kola, 2015, An outbreak of carbapenem-resistant OXA-48—producing Klebsiella pneumonia associated to duodenoscopy, Antimicrob Resist Infect Control, 4, 8, 10.1186/s13756-015-0049-4
Verfaillie, 2015, Withdrawal of a novel-design duodenoscope ends outbreak of a VIM-2-producing Pseudomonas aeruginosa, Endoscopy, 47, 493, 10.1055/s-0034-1391886
Loeve, 2012
GmbH O. Field safety corrective action—EVIS EXERA II DUODENOVIDEOSCOPE TJF-Q180V. 2014.
GmbH O. Important safety advice—safe reprocessing of TJF-Q180V. 2013.
Media Statement Regarding CRE and Duodenoscope [press release]. March 4, 2015.
Cavaliere, 2015
UCLA statement on notification of patients regarding endoscopic procedures [press release]. February 18, 2015.
Ross, 2015, A quarantine process for the resolution of duodenoscope-associated transmission of multidrug-resistant Escherichia coli, Gastrointest Endosc, 82, 477, 10.1016/j.gie.2015.04.036
Muscarella, 2014, Risk of transmission of carbapenem-resistant Enterobacteriaceae and related “superbugs” during gastrointestinal endoscopy, World J Gastrointest Endosc, 6, 457, 10.4253/wjge.v6.i10.457
Rauwers, 2018, High prevalence rate of digestive tract bacteria in duodenoscopes: a nationwide study, Gut, 67, 1637, 10.1136/gutjnl-2017-315082
Naryzhny, 2016, Impact of ethylene oxide gas sterilization of duodenoscopes after a carbapenem-resistant Enterobacteriaceae outbreak, Gastrointest Endosc, 84, 259, 10.1016/j.gie.2016.01.055
Kim, 2016, Risk factors associated with the transmission of carbapenem-resistant Enterobacteriaceae via contaminated duodenoscopes, Gastrointest Endosc, 83, 1121, 10.1016/j.gie.2016.03.790
2015, Interim protocol for healthcare facilities regarding surveillance for bacterial contamination of duodenoscopes after reprocessing
Administration FaD. Materials of the Gastroenterology-Urology Devices Panel. June 15, 2015.
2015, Supplemental measures to enhance duodenoscope reprocessing: FDA Safety Communication
2015, Reprocessing medical devices in health care settings: validation methods and labeling guidance for industry and food and drug administration staff
Urgent safety notification important updated labeling information: new reprocessing instructions for the Olympus TJF-Q180V duodenoscope. (2015).
Higa, 2018, Optimizing duodenoscope reprocessing: rigorous assessment of a culture and quarantine protocol, Gastrointest Endosc, 88, 223, 10.1016/j.gie.2018.02.015
Corporation O. Urgent medical device removal and corrective action: elevator mechanism replacement, updated operation manual, and new reprocessing instructions for the Olympus TJF-Q180V Duodenoscope. 2016.
Administration UFaD. Fujifilm issues voluntary recall of all ED-530XT duodenoscopes with FDA cleared updated design and labeling for the ED-530XT August 3, 2017.
Administration UFaD. Pentax issues voluntary recall of all Ed-3490TK and ED-3270K duodenoscopes. 2018.
2016
GESA. Infection control in endoscopy consensus statements on carbapenemase-producing enterobacteriaceae. 2017.
SHEA A. APIC and SHEA statement on infections associated with duodenoscope procedures. 2015.
Beilenhoff, 2007, ESGE/ESGENA guideline for process validation and routine testing for reprocessing endoscopes in washer-disinfectors, according to the European Standard prEN ISO 15883 parts 1, 4 and 5, Endoscopy, 39, 85, 10.1055/s-2006-945191
Beilenhoff, 2007, ESGE-ESGENA guideline for quality assurance in reprocessing: microbiological surveillance testing in endoscopy, Endoscopy, 39, 175, 10.1055/s-2006-945181
Murdani, 2017, WEO position statement on hygiene in digestive endoscopy: Focus on endoscopy units in Asia and the Middle East, Dig Endosc, 29, 3, 10.1111/den.12745
Devereaux, 2019, Australian infection control in endoscopy consensus statements on carbapenemase-producing Enterobacteriaceae, J Gastroenterol Hepatol, 34, 650, 10.1111/jgh.14511
Committee BSoGE. Guidelines for decontamination of equipment for gastrointestinal endoscopy. 2014.
(AGA) AGA. How to stop duodenoscope infections. Online; March 23rd, 2015.
AGA Supports New Government Scope Safety Protocols [press release]. Online, February 27, 2018.
(ASGE) ASfGE. ASGE Duodenoscope Infection Control Summit Executive Summary. Online; March 30, 2019.
Thaker, 2018, Duodenoscope reprocessing practice patterns in U.S. endoscopy centers: a survey study, Gastrointest Endosc, 88, 316, 10.1016/j.gie.2018.04.2340
Molloy-Simard, 2018, Elevating the standard of endoscope processing: terminal sterilization of duodenoscopes using a hydrogen peroxide-ozone sterilizer, Am J Infect Control
(EPA) United States Environmental Protection Agency. Sterigenics Willowbrook Facility - Updates. 2019. https://www.epa.gov/il/sterigenics-willowbrook-facility-updates. Accessed April 30, 2019.
Snyder, 2017, Randomized comparison of 3 high-level disinfection and sterilization procedures for duodenoscopes, Gastroenterology, 153, 1018, 10.1053/j.gastro.2017.06.052
Bartles, 2018, A randomized trial of single versus double high-level disinfection of duodenoscopes and linear echoendoscopes using standard automated reprocessing, Gastrointest Endosc, 88, 306, 10.1016/j.gie.2018.02.016
Administration UFaD. The FDA provides interim results of duodenoscope reprocessing studies conducted in real-world settings: FDA safety communication. 2018.
Administration USFaD. Statement from Jeff Shuren, MD, JD, Director of the Center for Devices and Radiological Health, on updated safety communication about rates of duodenoscope contamination from preliminary postmarket data. 2018.