Drop behavior in a pilot plant asymmetric rotating disc extraction column for three various liquid–liquid systems
Tài liệu tham khảo
Abdeltawab, 2002, Separation of La and Ce with PC-88A by counter-current mixer-settler extraction column, Sep. Purif. Technol., 26, 265, 10.1016/S1383-5866(01)00180-0
Al-Rahawi, 2007, New predictive correlations for the drop size in a rotating disc contactor liquid–liquid extraction column, Chem. Eng. Technol., 30, 184, 10.1002/ceat.200600278
Dutta, 2009
Gameiro, 2010, Copper extraction from ammoniacal medium in a pulsed sieve-plate column with LIX 84-I, J. Hazard. Mater., 183, 165, 10.1016/j.jhazmat.2010.07.006
Godfrey, 1994
Hemmati, 2015, A study of drop size distribution and mean drop size in a perforated rotating disc contactor (PRD), Chem. Eng. Res. Des., 96, 54, 10.1016/j.cherd.2015.02.005
Kadam, 2009, Hydrodynamic and mass transfer characteristics of asymmetric rotating disc extractors, Chem. Eng. Res. Des., 87, 756, 10.1016/j.cherd.2008.10.001
Kislik, 2012
Kumar, 1996, Unified correlations for the prediction of drop size in liquid–liquid extraction columns, Ind. Eng. Chem. Res., 35, 2682, 10.1021/ie950674w
Kumar, 1986, Capacity and hydrodynamics of an agitated extraction column, Ind. Eng. Chem. Process Des. Dev., 25, 728, 10.1021/i200034a022
Mills, 1984, The selection of liquid–liquid extraction contactors for nuclear fuel reprocessing, Eraction'84, Symposium on Liquid?Liquid Extraction Science, 245, 10.1016/B978-0-08-031439-6.50023-4
Míšek, 1985, Standard test systems for liquid extraction studies, EFCE Publ. Ser.
Misek, 1970, Asymmetric rotating extractor, Br. Chem. Eng., 15, 202
Montgomery, 1994
Moreira, 2007, Hydrodynamic behavior of a rotating disc contactor under low agitation conditions, Chem. Eng. Commun., 192, 1017, 10.1080/009864490522542
Morı́s, 1999, Solvent extraction of molybdenum and tungsten by Alamine 336 and DEHPA in a rotating disc contactor, Sep. Purif. Technol., 17, 173, 10.1016/S1383-5866(99)00022-2
Rydberg, 2004
Sindermann, 2016, Single stage and countercurrent extraction of 5-hydroxymethylfurfural from aqueous phase systems, Chem. Eng. J., 283, 251, 10.1016/j.cej.2015.07.029
Slater, 1985, Liquid–liquid extraction column design, Can. J. Chem. Eng., 63, 1004, 10.1002/cjce.5450630620
Sun, 2015, Mixer-settler operation for the recovery of platinum, iron and hydrochloric acid from the leaching solution of spent petroleum reforming catalysts, J. Ind. Eng. Chem., 21, 134, 10.1016/j.jiec.2014.02.049
Thornton, 1992
Torab-Mostaedi, 2011, Flooding and drop size in a pulsed disc and doughnut extraction column, Chem. Eng. Res. Des., 89, 2742, 10.1016/j.cherd.2011.06.006