Jiménez Ormabera B, Díez Valle R, Zaratiegui Fernández J, Llorente Ortega M, Unamuno Iñurritegui X, Tejada SS. Impresión 3 D en neurocirugía: modelo específico para pacientes con craneosinostosis. Neurocirugia. 2017;28(6):260–5. https://doi.org/10.1016/j.neucir.2017.05.001.
Haffner M, Quinn A, Hsieh T, Strong EB, Steele T. Optimization of 3D print material for the recreation of patient-specific temporal bone models. Ann Otol Rhinol Laryngol. 2018;127(5):338–43. https://doi.org/10.1177/0003489418764987.
Ganguli A, Pagan-Diaz GJ, Grant L, Cvetkovic C, Bramlet M, Vozenilek J, et al. 3D printing for preoperative planning and surgical training: a review. Biomed Microdevices. 2018;20(3):65. https://doi.org/10.1007/s10544-018-0301-9.
Antony AK, Chen WF, Kolokythas A, Weimer KA, Cohen MN. Use of virtual surgery and Stereolithography-guided osteotomy for mandibular reconstruction with the free fibula. Plast Reconstr Surg. 2011;128(5):1080–4. https://doi.org/10.1097/PRS.0b013e31822b6723.
Kass JI, Prisman E, Miles BA. Guide design in virtual planning for scapular tip free flap reconstruction. Laryngoscope Investig Otolaryngol. 2018;3(3):162–8 Available from: http://doi.wiley.com/10.1002/lio2.162.
Mitsouras D, Liacouras P, Imanzadeh A, Giannopoulos AA, Cai T, Kumamaru KK, et al. Medical 3D printing for the radiologist. RadioGraphics. 2015;35(7):1965–88 Available from: http://pubs.rsna.org/doi/10.1148/rg.2015140320.
Mitsouras D, Liacouras PC, Wake N, Rybicki FJ. RadioGraphics update: medical 3D printing for the radiologist. RadioGraphics. 2020;40(4):E21–3. Available from. https://doi.org/10.1148/rg.2020190217.
George E, Liacouras P, Rybicki FJ, Mitsouras D. Measuring and establishing the accuracy and reproducibility of 3D printed medical models. RadioGraphics. 2017;37(5):1424–50. Available from. https://doi.org/10.1148/rg.2017160165.
Christensen A, Rybicki FJ. Maintaining safety and efficacy for 3D printing in medicine. 3D Print Med. 2017;3(1):1 Available from: https://threedmedprint.biomedcentral.com/articles/10.1186/s41205-016-0009-5.
Alexander AE, Wake N, Chepelev L, Brantner P, Ryan J, Wang KC. A guideline for 3D printing terminology in biomedical research utilizing ISO/ASTM standards. 3D Print Med. 2021;7(1):8 Available from: https://threedmedprint.biomedcentral.com/articles/10.1186/s41205-021-00098-5.
Shea GK-H, Wu KL-K, Li IW-S, Leung M-F, Ko AL-P, Tse L, et al. A review of the manufacturing process and infection rate of 3D-printed models and guides sterilized by hydrogen peroxide plasma and utilized intra-operatively. 3D Print Med. 2020;6(1):7.
Gür Y. Additive manufacturing of anatomical models from computed tomography scan data. MCB Mol Cell Biomech. 2015;11(4):249–58.
Popescu D, Vlasceanu D, Cursaru L, Baciu F, Hadar A. Low-temperature sterilization influence on fused deposition modelling parts. Proc Manuf Syst. 2016;11(3):151–8.
Popescu D, Baciu F, Vlăsceanu D, Cotruţ CM, Marinescu R. Effects of multiple sterilizations and natural aging on the mechanical behavior of 3D-printed ABS. Mech Mater. 2020;148(May):103423. https://doi.org/10.1016/j.mechmat.2020.103423.
McEvoy B, Rowan NJ. Terminal sterilization of medical devices using vaporized hydrogen peroxide: a review of current methods and emerging opportunities. J Appl Microbiol. 2019;127(5):1403–20. https://doi.org/10.1111/jam.14412.
US-FDA. Use of International Standard ISO 10993-1, “Biological evaluation of medical devices-Part 1: evaluation and testing within a risk management process” guidance for industry and Food and Drug Administration staff. US Dep Heal Hum Serv Food Drug Adm. 2020;(301):1–68 Available from: https://www.fda.gov/vaccines-blood-biologics/guidance-compliance-regulatory-information-%0Ahttp://www.fda.gov.proxy1.library.jhu.edu/downloads/medicaldevices/deviceregulationandguidance/guidancedocuments/ucm348890.pdf.
Chepelev L, Wake N, Ryan J, Althobaity W, Gupta A, Arribas E, et al. Radiological Society of North America (RSNA) 3D printing Special Interest Group (SIG): guidelines for medical 3D printing and appropriateness for clinical scenarios. 3D Print Med. 2018;4(1):11.
Malik HH, Darwood ARJ, Shaunak S, Kulatilake P, El-Hilly AA, Mulki O, et al. Three-dimensional printing in surgery: a review of current surgical applications. J Surg Res. 2015;199(2):512–22. https://doi.org/10.1016/j.jss.2015.06.051.
Kim GB, Lee S, Kim H, Yang DH, Kim Y-H, Kyung YS, et al. Three-dimensional printing: basic principles and applications in medicine and radiology. Korean J Radiol. 2016;17(2):182–97. https://doi.org/10.3348/kjr.2016.17.2.182.
Katatny IE, Masood SH, Morsi YS. Evaluation and validation of the shape accuracy of FDM fabricated medical models. Adv Mater Res. 2009;83–86:275–80.
Hsu C, Lin C, Fan C, Chiang N Y, Tsai C W, Chang C M, et al. Shape accuracy of an acrylonitrile butadiene styrene canine tibia model fabricated using fused deposition modelling and the effects of hydrogen peroxide gas plasma sterilisation. BMC Vet Res. 2020:1–18. https://doi.org/10.21203/rs.3.rs-35517/v1.
Neches RY, Flynn KJ, Zaman L, Tung E, Pudlo N. On the intrinsic sterility of 3D printing. PeerJ. 2016;4(12):e2661. https://doi.org/10.7717/peerj.2661.
Marei HF, Alshaia A, Alarifi S, Almasoud N, Abdelhady A. Effect of steam heat sterilization on the accuracy of 3D printed surgical guides. Implant Dent. 2019;28(4):372–7. https://doi.org/10.1097/ID.0000000000000908.
Oth O, Dauchot C, Orellana M, Glineur R. How to sterilize 3D printed objects for surgical use? An evaluation of the volumetric deformation of 3D-printed Genioplasty guide in PLA and PETG after sterilization by low-temperature hydrogen peroxide gas plasma. Open Dent J. 2019;13(1):410–7. https://doi.org/10.2174/1874210601913010410.
Chen JV, Tanaka KS, Dang ABC, Dang A. Identifying a commercially-available 3D printing process that minimizes model distortion after annealing and autoclaving and the effect of steam sterilization on mechanical strength. 3D Print Med. 2020;6(1):9.
Shaheen E, Alhelwani A, Van De Casteele E, Politis C, Jacobs R. Evaluation of dimensional changes of 3D printed models after sterilization: a pilot study. Open Dent J. 2018;12(1):72–9. https://doi.org/10.2174/1874210601812010072.
Kuczko W, Wichniarek R, Górski F, Banaszewski J. Influence of sterilization of a product manufactured using FDM technology on its dimensional accuracy. Adv Sci Technol Res J. 2018;12(1):74–9. https://doi.org/10.12913/22998624/80849.