Development of correction schemes for a small field of view gamma camera

Springer Science and Business Media LLC - Tập 2 - Trang 215-222 - 2013
Nguyen Manh Hung1, Jinhun Joung1, Kisung Lee1, Yongkwon Kim1
1Department of Radiologic Science, Korea University, Seoul, Korea

Tóm tắt

The goal of this study is to develop data correction schemes for a small field of view (SFOV) high resolution gamma camera detector for a small organ dedicated system such as breast, thyroid and joints. The gamma camera contains PMTs coupled with single slap of NaI(TI) plate crystal. Correction schemes including energy, linearity and uniformity correction were developed. Energy and linearity correction was performed with 57Co sheet by utilizing same dot pattern phantom used for look up table (LUT) generation. Energy correction aligns the energy peaks of energy spectrum to reference energy by linear transformation. Linearity correction removes spatial distortions based on LUT of X, Y directions. Uniformity correction was executed with 99mTc flood source to redistribute counts in the image. This correction was based on pixel addition and subtraction for each event. The results showed calibration measure for dot pattern image acquired with 57Co sheet and flood field image obtained with 99mTc. This system acquired with 99mTc provided 17.54% FWHM energy resolution and 2.5% integral uniformity within a useful field of view (UFOV). The correction schemes in this paper showed good results about linearity and uniformity. The measured energy resolution of the system is not as high as what we had expected due to the limitation of the current version of DAQ in the prototype system. In the future, we will revise the hardware so that we can maximize the performance of the proposed methods.

Tài liệu tham khảo

Anger HO. Scintillation camera. Rev Sci Inst. 1958; N.29:27. Wang SX, Caruba JF, Chapmana JT, Malmin RE, Fang J. Systems and methods for camera calibration. U.S. Patent No. 7,417,232 B2, Aug. 26, 2008. Wang SX, Caruba JF, Malmin RE, DelMedico AP. Nonuniformity energy correction method and apparatus. U.S. Patent No. 7,449,680 B2, Nov. 11, 2008. Barfod JM. Gamma camera with image uniformity by energy correction offsets. U.S. Patent No. 4,899,054, Feb. 6, 1990. Cherry SR, James A. Sorenson, Micheal E. Phelphs. Physics in nuclear medicine. 3rd ed. Saunders, Philadelphia: 2003. pp. 227–272. Muehllehner G, Colsher JG, Stoub EW. Correction for field nonuniformity in scintillation cameras through removal of spatial distortion. IEEE T Nucl Sci. 1980; NS-31(1): 771–776. King SE, Jih F, Lim CB, Chaney R, Gray E. Spectral-spatialsensitivity distortion trends and an accurate correction method in scintillation gamma cameras. IEEE T Nucl Sci. 1985; NS-32(1): 870–874. Martin Marsden. Cubic spline interpolation of continuous functions. J Approx Theory. 1974; 10: 103–111. Hou HS, Andrews HC. Cubic spline for image interpolation and digital filtering. IEEE T Acoust Speech Signal Process. 1978; 26 i9: 508–517. Butt R. Introduction to numerical analysis using MATLAB: Jones & Bartlett Learning; 2009. Prekeges J. Nuclear medicine instrumentation. Jones and Bartlett Publishers, Canada. 2012. pp. 53–71. Villena JL, Tapias G, Lage E, Kreuger R, Beekman FJ. Evaluation of a 25–511keV list mode readout system for a large field-of-view gamma camera. Conf Rec IEEE NSS-MIC 2010.